Pelco WCSI-4 - page 1
WCS1-4 Environmental Power Supply C561M-D (11/03) ® INST ALLA TION/OPERA TION ...
-
Pelco WCSI-4 - page 2
2 C561M-D (11/03) IMPORT ANT SAFEGUARDS AND W ARNINGS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified service personnel and conform to all local codes. 6. Use only installation methods and materials capable of supporting four times the maximum ...
-
Pelco WCSI-4 - page 3
C561M-D (11/03) 3 DESCRIPTION The WCS1-4 is a mutliple power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 is capable of powering up to four units and can handle pan/tilt, heater , blower , and camera operation. The WCS1-4 ...
-
Pelco WCSI-4 - page 4
4 C561M-D (11/03) INST ALLA TION MOUNTING INSTRUCTIONS To mount the power supply directly to a wallboard, wall, or concrete refer to Figures 1 through 3 and do the following: 1. Remove the retaining screw from the door latch of the WCS1-4 power supply . 2. Open the door of the WCS1-4 power supply , and then remove the plug(s) from the required cond ...
-
Pelco WCSI-4 - page 5
C561M-D (11/03) 5 FUSE INST ALLA TION The WCS1-4 power supply is shipped from the factory with a 1.6-amp fuse installed for 100/120 V AC input power . T o use input power of 230 VAC, change the 1.6-amp fuse to a 500-milliamp fuse (supplied). To change the fuse remove the lid to the fuse holder (refer to figure 4) located inside the power supply and ...
-
Pelco WCSI-4 - page 6
6 C561M-D (11/03) OUTPUT WIRING To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to T able A and determine the output connection needed for your camera, dome, or positioning system. Refer to Figure 4, for the proper connector strip connections. 2. Attach one output wire to eit ...
-
Pelco WCSI-4 - page 7
C561M-D (11/03) 7 CABLE CONNECTIONS AND REQUIREMENTS Table A. Wiring Distances The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III or Esprit positioning system. To determine the correct voltage tap: 1. Pick the unit type. 2. Find the wire gauge used (22 gauge is not recommended). 3. Determine which secondary outp ...
-
Pelco WCSI-4 - page 8
8 C561M-D (11/03) MAINTENANCE There are no user -serviceable parts except for the fuse. If the transformer in the WCS1-4 does not work properly , the entire environmental power supply needs to be returned to the factory for repair . Refer to the Wa rranty and Return Information for instructions on returning the WCS1-4. Clean the outer surface of th ...
-
Pelco WCSI-4 - page 9
C561M-D (11/03) 9 SPECIFICA TIONS ELECTRICAL Input V oltage: Selectable 100, 120, 230 V AC, 50/60 Hz via the Primary Line Input connector strip Output V oltage/Power: Selectable 24 V AC (T ap A), 26 VAC (T ap B), or 28 VAC (T ap C) at 100 V A via the Secondary Output T ap’ s connector strip Fusing: One fuse. Select from one of the following suppl ...
-
Pelco WCSI-4 - page 10
10 C561M-D (11/03) Figure 5. WCS1-4 Dimension Drawing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES. 6.50 (16.51) 5.63 (14.30) 4.50 (11.43) 6.44 5.88 (14.94) 4.00 (10.16) 7.88 (20.02) (16.36) ...
-
Pelco WCSI-4 - page 11
C561M-D (11/03) 11 W ARRANTY AND RETURN INFORMA TION W ARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC ...
-
Pelco WCSI-4 - page 12
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada Singapore ® ...
Pelco WCSI-4についてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもPelco WCSI-4の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco WCSI-4で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。