Bradford White IGI-180Cの取扱説明書

60ページ 2.04 mb
ダウンロード

ページに移動 of 60

Summary
  • Bradford White IGI-180C - page 1

    BRADFORD WHITE EVERHOT ® TANKLESS GAS WATER HEATER FOR INTERIOR INSTALLATION IGI-180R AND IGI-180C MODEL SERIES  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance  WHAT TO DO IF YOU SMELL GA S • Do not try to light any appliance. • Do not touch any electrical switch; do not ...

  • Bradford White IGI-180C - page 2

    2 SECTION I: IMPORTANT INFORMATION This water heater has a limited warrant y . The warrant y for this water heater is valid onl y if the water heater has been installed, maintained and operated in acco rdance with these instructions. NOTICE Indicates an imminently hazardous situation, which, if not avoided, will result in death, serious injury or s ...

  • Bradford White IGI-180C - page 3

    DO NOT store or use gasolin e or other flam mable, com bustible, or corrosi ve vapors and/ or liquids in the vicinity of this or any othe r appliance . Failure to pr operly install the vent an d air intake (if applica b le) system could result in propert y damage, personal injury, or death. DANGER DO NOT install any damaged venting syst em com pone ...

  • Bradford White IGI-180C - page 4

    DO NOT operate water heater with jumpered or absent controls or safety devices. DO NOT oper ate water he ater if an y external part has been unde r water. Immediatel y call a qualified service a g enc y to inspect the appliance and to replace an y part o f the con trol s y stem including gas cont rols, which has been under water. DO NOT attempt to ...

  • Bradford White IGI-180C - page 5

    Liquefied petroleum gases/propane gas is heavier than air and will remain at floor level if there is a leak. Basements, crawl spaces, closets and ar eas below ground level will serve as pockets fo r accumulation of leaking gas. Before lighting, sm ell all around the appliance ar ea for gas. Be sure to smell next to the floor. IF YOU SMELL GAS: • ...

  • Bradford White IGI-180C - page 6

    SECTION II: SPECIFICATIONS Max. Flow Rate @ Degree Temperature Rise Model No. Max. Input Rating Btu/hr. Min. Input Rating Btu/hr. Temp Rise 40 ° F 60 ° F 80 ° F 100 ° F 120 ° F 140 ° F Flow Rate Gal/Min. 7.7 5.1 3.8 3.1 2.6 2.2 IGI-180R-10N IGI-180R-10X IGI-180C-5N IGI-180C-5X 180,000 15,000 First Hour Supply Gal/Hr . 462 306 228 186 156 132 ...

  • Bradford White IGI-180C - page 7

    EVERHOT ® IGI Model Series Dimensions 7 ...

  • Bradford White IGI-180C - page 8

    SPECIFICATIONS Dimensions (Inches) Height: 25 5/8” (65.1 cm) Width: 13 25/32” (35 cm) Depth: 8 13/16” (22.4 cm) Outside Vent Connectio n: 5” dia. (12.7 cm) Venting Height: 2 21/32” (6.7 cm) Above top of cabinet Cleara nces from Combustible Materials: Top of wate r heater: 6” (15.2 cm), Front: 6” (15.2 cm), Sides: 2” (5.1 cm), Back: ...

  • Bradford White IGI-180C - page 9

    9 SECTION III: GENERAL INFORMATION FEATURES The Bradford White EVERHOT ® IGI series tankl ess water heater is a high output, high efficiency appliance, which heat s the water conti nuously as hot water is being drawn for u se. Unlike tank type storage water heaters, this water heat er doe s not store hot water. The bu rne r operates whenever there ...

  • Bradford White IGI-180C - page 10

    SECTION IV: INSTALLATION INSTRUCTIONS This water heater must b e located in an area where lea kage of the heat exchange r coil, water line connections, or the pressure relief valve will not result in damage to the area adjacent to the water heater or to lo wer floors of the st ructure. Whe n such locations cannot be avoided, a suitable dr ain pa n ...

  • Bradford White IGI-180C - page 11

    WARNING • This water heater is suitable for potable w ater heating only. DO NOT use this water heater for space heating or combination space he ating/domestic water heating. • This water heater is not suitable for use in pool or spa application s. • The water heater must be installed indoors using the proper venting system components for comb ...

  • Bradford White IGI-180C - page 12

    12 Connectors of this water h eater. However, it is recommend ed that at least 12” (30.5 cm) f rom the top and 24” (61 cm) from the fr ont be provided for servicing. 4. If the water heater is installed i n a confined sp ace , such as a closet, ventilation air must be provided to prevent increased room temperature. Excessive ambient temp erature ...

  • Bradford White IGI-180C - page 13

    SECTION V: WA TER CONNECTIONS WARNING Failure to install and maintain a new, li sted pressu re relief valve will release the man ufacturer from any claim, which might result from excessive temperature and pressures. Keep clear of the pressure relief valve discha rge line outlet. The discharge may be hot enoug h to cause scald injury. The water is u ...

  • Bradford White IGI-180C - page 14

    14 plumbing system to the house. All soldering m aterials and piping m ust be compatible with potable water. Unions should be installe d on both the hot and cold water lines fo r future servicing and disconnection of the water heater. Install a shut -off valve in the cold water sup ply line. 2. In order to service the water heater in the ev ent the ...

  • Bradford White IGI-180C - page 15

    Recommended Piping for a Basic Installation (Fig. 1) 15 ...

  • Bradford White IGI-180C - page 16

    Recommended Piping for a Circulation Sy stem (Fig. 2) 16 ...

  • Bradford White IGI-180C - page 17

    Recommended Piping for Po wer Failure Freeze Protection As long as electrical power and gas are supplied to the EVERHOT ® water heater, free ze protection is provided to the heat exch anger and pi ping inside the wate r he ater with ambient temperatures as cold as -30 ° F (-34 ° C), when protected from direct wi nd exposure. In the event of a po ...

  • Bradford White IGI-180C - page 18

    Recommended Piping for Back-up Sto rage System For hotels, motels, and other high flo w applications (Fig. 4) Note: The Primary Circulator for the water hea tin g loop must be sized for 21 GPM @ 35 Ft. Head 18 ...

  • Bradford White IGI-180C - page 19

    PRESSURE RELIEF VALVE – 19 Keep clear of the pressu re relief valve dischar ge line outlet. The discha rge may be hot enough to cause scald injury. The water is unde r pressure and m ay splash. For protection against excessive pressure, insta ll pressure protective equipment req uired by local codes, but not less than a pressure reli ef val ve ce ...

  • Bradford White IGI-180C - page 20

    SECTION VI: VENTING WARNING The venting system must be properly installed. Failure to properly install the vent system coul d result in property damage, personal injury, or death. DO NOT install damaged venting system comp onents. If damage is evident then please contact the supplier where the water h eater was p urchased or the manufactu re r list ...

  • Bradford White IGI-180C - page 21

    VENT/AIR INTAKE TERMINAL L OC ATI ONS Direct Vent Terminal Location Plan the vent system layout so that proper clearan ces are maintained from plumbin g and wiring. Before the vent is installed, dete rmine the vent pipe terminatio n location as sho wn below in the Vent Terminal Location illustration. Vent/Air Intake Terminal Po sitions – MINIMUM ...

  • Bradford White IGI-180C - page 22

    22 Vent terminals must terminate at least 3 feet (0.9 m) above any forced air inlet locate d within 10 feet (3.1 m). This provision does not apply to: 1. The combustion air intake of a direct vent appliance or the circulating ai r inlet and flue gas discharge of listed outdoor applia nces. 2. The exhaust vent terminal must be installed with at leas ...

  • Bradford White IGI-180C - page 23

    23 Venting Table – Examples of Maximum Venting Distances w ith Various Elbow Combinations Maximum Straight Pipe Distance Number of 90 degree elbows Number of 45 degree elbows Maximum Total Equivalent Feet (meters) of Vent Pipe 35 Ft. (10.7 m) 1 41 (12.5 m) 29 Ft. (8.8 m) 2 41 (12.5 m) 23 Ft. (7.0 m) 3 41(12.5 m) 17 Ft. (5.2 m) 4 41 (12.5 m) 33.5 ...

  • Bradford White IGI-180C - page 24

    VENTING SYSTEM INSTALLATION Reference the preceding section and venting compone nts illustrations at the end of this man ual to determine the parts required for your particul ar vent ing system installation. The required ventin g component parts are available from your Bradford White supplier. Use the Venting System Installatio n Instructions suppl ...

  • Bradford White IGI-180C - page 25

    Horizontal Direct Vent using standard vent kit componen ts: Fig. 5 For installations on interior walls, ven ting components may be purcha sed from your Bradford White supplier to extend the venting distan ce using extens ion tubes and elbows. Use the formula and venting table shown previously in this installatio n manual to calculate the total equi ...

  • Bradford White IGI-180C - page 26

    Horizontal Direct Vent using extensi on components for long er vent runs: Fig. 6 Vertical Direct Vent Installations The EVERHOT ® IGI series water heater can also be installed to vent vertically through the roof using a vertical discharge adaptor, optional vent extension tubes, a co ndensat e collector, a roof terminal, and a universal lead tile. ...

  • Bradford White IGI-180C - page 27

    Fig. 7 Vertical Vent Installations The condensate collecto r will require a ¾” CPVC pipe connectio n with a trap to act as a seal against discharging flue prod ucts into the room. Run th e condensate line to a suitable drai n. The conden sate collector must be located within 5 feet (1. 52 m) of the water heater vent connection. NOTICE The Conden ...

  • Bradford White IGI-180C - page 28

    Combustion Blo wer Dip Switch Settings for Ve nt Length Compensation Under 22 Feet (6.7 m): To assure optimum efficiency and redu ced noise levels, the combustion blower switch h as two dip switch settings. Dip switch numbe r 1 (top dip switch) is shipped from the factory set to the OFF po sition to compensate for the maximum vent/air intake length ...

  • Bradford White IGI-180C - page 29

    SECTION VII: GAS CONNECTIONS WARNING Connect this water heater only to the type of gas as sh own on the rating plate. Use clean black iron pipe or equivalent material app roved by local codes and ordin ances. (Dirt and scale from the pi pe can enter the gas valve and cause it to malfun ction). The inlet gas li ne must have at least a 3 inch (7.62 c ...

  • Bradford White IGI-180C - page 30

    GAS METER SIZE –NATURAL GAS ONLY Be sure that the gas meter has sufficient capacity to supply the full rated gas in put of the water heater as well as the requirements of all other gas fired equi pment supplied by the meter. If the gas meter is too small, ask the gas company to install a larger mete r h aving adequate capacity. GAS PRESSURE REGUL ...

  • Bradford White IGI-180C - page 31

    31 4. Turn power on (after completing electrical co nnections – refer to Section VIII, “Electrical Connections”) and fully open a hot water tap. 5. Measure the gas pressures to see that these are within the specified limits below: Supply Pressure: Nat. Gas: Min.: 6”, Max.: 10.5” L.P. Gas: Min.: 10”, Max: 13.5” w.c. Manifold Pressure: ...

  • Bradford White IGI-180C - page 32

    SECTION VIII: ELECTRICAL CONNECTIONS WARNING Turn off or disconnect the electrical power supply to the water heater before servicing. Label all wires prior to disconnection when servicing controls. Wirin g errors can cause improper an d dangerous operation. Verify proper operation after servicing. All electrical wiring must be installed and grou nd ...

  • Bradford White IGI-180C - page 33

    Wiring Diagram WARNING DO NOT adjust any dipswitch settings on PC board except Dip Swi tch #1, if required, for vent length. 33 ...

  • Bradford White IGI-180C - page 34

    Wiring Diagram – Schematic 34 ...

  • Bradford White IGI-180C - page 35

    TEMPERATURE CONTROLS The front panel temperature control allows the cust om er to set the hot water supply temperature and will display certain fault functions of t he water heater if there i s a malfunction. Re sidential models can also have the option of up to two additional bathroom tem perature controls located near bathroom fixtures for conven ...

  • Bradford White IGI-180C - page 36

    Before installing the Bath Controls, determine the most conveni ent locations(s). When deciding o n the best location for the remote controls, please co nsider the following items: 1. Place the controls out of reach of small children. 2. Avoid locations where the control (s) will become hot, such as over a radiator, registe r, or other heat sources ...

  • Bradford White IGI-180C - page 37

    Note: If the cable cannot be run in side the wall ca vity, then the plastic kn ockout should be remove d from the top or bottom of the control to allow flush mounting with the wall. 7. Disconnect the power from the water heater and remove the front cover. 8. Remove the plastic cover from the PCB and electrical connectio ns. 9. Thread the cable th r ...

  • Bradford White IGI-180C - page 38

    WARNING When the Water Heater or remotely located Main Co n trol is used in public use applications, it shall be installed in a location where it can not be adjus ted by the public (i.e., a m aintenance room or manager’s office). Unauthorized adjust ments may re sult in scalding conditions. NOTICE Only one remote control can be connected to one C ...

  • Bradford White IGI-180C - page 39

    Remote Control Wiring Connections Inside Water Heater (Fig. 11) INITIAL OPERATION AN D TESTING OF CONTRO LS (INSTAL LER ONLY) 1. Turn on power to the water heater and fully open a hot water tap. 2. Check the operatio n of the water heater. Check the ope ration of the remote temperature control(s). Check the operati on of the power failure protectio ...

  • Bradford White IGI-180C - page 40

    SECTION IX: OPERATING INSTRUCTIONS WARNING Water heaters are he at-producing appliances. To avoid damage or injury there must be n o materials stored against the water heater or d irect vent system, and proper ca re must be taken to avoid unnecessary contact (e specially by children) with the water heater and direct ve nt system. UNDER NO CIRCUMSTA ...

  • Bradford White IGI-180C - page 41

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFO RE OPERATIN G WARNING: If you do not follo w these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with a direct ignition device, which automatically lights the burner. Do not try to ...

  • Bradford White IGI-180C - page 42

    42 CAUTION In climates where below freezing tempe ratures may occur, the water heater must be d rained when power is off to the water heater to prev ent free ze damage to the heat exchanger. Drain sol enoids are recommended to prevent freeze damage during p ower failures in cold climate regions. TURNING OFF THE WATER HEA TER FOR AN EXTENDED PERIOD ...

  • Bradford White IGI-180C - page 43

    TEMPERATURE ADJUSTMENT DANGER Hotter water increases the risk of scald inj ury. Scalding may occu r within 5 seco nds at a temperature setting of 135 ° F (57 ° C). To protect against hot water injury, install a mixing valve in the water system. This valve will reduce point of discharge temperature by mixing cold and hot water in branch water lin ...

  • Bradford White IGI-180C - page 44

    7. To display the water flow through the water heat er with hot water in use, depress the “H” bu tton for 2 seconds and then simultaneously p ress the “P” button. (GPM = Display Re adout X 0.1). 8. To display the outlet water temperature while in use, depress the “C” button for 2 seconds and then simultaneously press the “P” button. ...

  • Bradford White IGI-180C - page 45

    6. Pressing the “Maintenance Button” followed by the “H” button will display a se quence of error codes, if any, stored i n memory that has bee n experienced. Any cu rrent error codes will be displayed on the digital monitor in seque nce starting with the most rece nt code. 7. To display the water flow through the water heat er with hot wat ...

  • Bradford White IGI-180C - page 46

    SCALDING This water heater can deliver scalding temperature water at any faucet in the system. Be careful whenever using hot water to avoid scalding injury. Ce rtain appliances such as dishwashe rs and automatic clothes washers may require increased tem perature water. By setti ng the thermostat on this water heater to obtain the increased te mpera ...

  • Bradford White IGI-180C - page 47

    FIRST AID FOR SCALDS 1. Remove all wet clothing quickly. Wet clothing retains the heat. 2. Apply cold water to burned are a for 30 minutes to reduce the h eat in the skin and prevent d eeper burning. Never use butter, oils, or ointm ent to cover the burn. They may retain the heat. 3. Use a blanket to keep the scalded person warm. 4. Seek medical ad ...

  • Bradford White IGI-180C - page 48

    SECTION X: MAINTENANCE WARNING Always turn off the electrical power supply, the manual gas valve, and the manual water control valve whenever servicing this applian ce. KEEP THE APPLIANCE AREA CLEAR AN D FREE FROM COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS. The EVERHOT ® water heater should be checked annually by a qua ...

  • Bradford White IGI-180C - page 49

    Burner Flame Appearance (Fig. 13) CAUTION Before manually operating the valve, make sure that a drain line has been attached to the valve to direct the discharge to an open drain. Failure to take this precaution could mean contact with extremely hot water passing out the valve during this che cking operation. FLUSHING PROCEDURE FOR LIME SCALE REMOV ...

  • Bradford White IGI-180C - page 50

    9. Run hose from hot water outlet to a drain. 10. Close the drain valve on the cold water inlet. Leave hot wate r drain valve open. Open cold water inlet to flush with fresh water. 11. Allow water to flow out of the hose for 5 minutes to flush vinegar from the water heater. 12. Shut off cold water inlet valve. Remove filt er screen and clean out an ...

  • Bradford White IGI-180C - page 51

    51 COMMON TROUBLESHOO TING COMMENTS ON T HE OPERATION OF T HE EVERHOT ® TANKLESS WATER HEATER Comment: I don’t have any hot water when I open the tap! Make sure the gas and el ectricity is turned on to the water hea ter. The remote temperature di splay should have the green light lit when a hot water tap is open and the water he ater is operatin ...

  • Bradford White IGI-180C - page 52

    Schematic Diagram of Internal Parts 52 ...

  • Bradford White IGI-180C - page 53

    SECTION XI: PARTS LIST Exploded View – Cabinet 53 ...

  • Bradford White IGI-180C - page 54

    Exploded View – Internal Components 54 ...

  • Bradford White IGI-180C - page 55

    Exploded View – Internal Components 55 ...

  • Bradford White IGI-180C - page 56

    Exploded View – Electrical 56 ...

  • Bradford White IGI-180C - page 57

    VENTING COMPONENTS 57 ...

  • Bradford White IGI-180C - page 58

    58 PARTS LIST Number Description Quantity 001 Casing Assembly 1 002 Wall Fitting Bracket 2 003 Rubber Bushing 1 004 Connection Reinforcement Panel 1 005 Heat Protection Plate 1 006 Front Panel 1 007 Front Panel Gasket 1 008 Front Panel Gasket – Side 2 100 Gas Control Assembly 1 101 Screw 2 102 Gas Connection (3/4” NPT ) 1 103 Burner Unit Assemb ...

  • Bradford White IGI-180C - page 59

    59 Number Description Quantity 406 Water Filter Assembly 1 407 Filter Plug 1 408 Hot Water Outlet – ¾” NPT 1 409 Sensor Bracket 1 410 Small Plug Gasket 1 411 Drain Valve 1 700 PCB Board Assembly 1 701 Surge Protector 1 702 PCP Cover - Side 1 703 PCB Cover - Front 1 704 Transformer 1 705 PCB Bracket 1 706 Igniter 1 707 High Te nsion Lead 1 708 ...

  • Bradford White IGI-180C - page 60

    60 VENTING COMPONENTS Part # Description Quantity 239-44516-00 Standard Vent Disc harge K it (Includes 1 Horizo ntal Discharge Adapter and 1 Wall Discharge Terminal) 1 239-44506-00 Horizontal Discharge Ada ptor 1 239-44505-00 Wall Discha rge Terminal (for wall thicknesses from 4” to 20”) 1 239-44500-00 Vertical Discharge Adaptor 1 239-44494-00 ...

メーカー Bradford White カテゴリー Water Heater

Bradford White IGI-180Cのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IGI-180Cの取扱説明書
- Bradford Whiteの製品カード
- パンフレット
- またはBradford White IGI-180Cの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bradford White IGI-180Cの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bradford White IGI-180Cの取り付け説明書、サービスマニュアル、簡易説明書、またはBradford White IGI-180Cのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bradford White IGI-180Cの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Bradford White IGI-180Cデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBradford White IGI-180Cを使用するのを助ける技術的文書のことです。説明書は通常、全てのBradford White IGI-180Cユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bradford Whiteの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bradford White IGI-180Cの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBradford White IGI-180Cの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bradford White IGI-180Cに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bradford White IGI-180Cデバイスの基本機能を使うにあたってのヒント。 Bradford White IGI-180Cのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bradford White IGI-180Cに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBradford White IGI-180Cのメーカー/サービスへの連絡先に関する情報。

Bradford White IGI-180Cについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBradford White IGI-180Cの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBradford White IGI-180Cで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)