    Digital Blood Pressure Monitor Model UA-767 BT-Ci Instruction Manual Original Manuel d ’ instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione Bedienungsanleitung Übersetzung 1WMPD4002749 ...

  • A&D BT-Ci - page 2

    ...

  • A&D BT-Ci - page 3

    English 1 Contents Dear Customers .......................................................................2 Preliminary Remarks .................................................................2 Precautions ..............................................................................2 Parts Identification ........................................... ...

  • A&D BT-Ci - page 4

    English 2 Dear Customers Congratulations on purchasing a st ate-of-the-art A&D blood pressure monitor, one of the most advanced m onitors available today. Designed for ease of use and accuracy, this m onitor will facilitat e your daily blood pressure regimen. We recommend that you read thro ugh this manual carefully before using the device for ...

  • A&D BT-Ci - page 5

    English 3 Measurements may be distorted if the device i s used close to televisions, microwave ovens, cellular telephones, X -ray or other devices with strong electrical fields. Used equipment, parts and batteri es are not treated as ordinary household waste, and must be dispos ed of according to the applicable local regulations. When the AC adapte ...

  • A&D BT-Ci - page 6

    English 4 Part s Identification Part of Display Pressure Bar Indicator MEMORY Systolic Pressure Diastolic Pressure Pulse Rate Battery Indicator I . H . B . I n d i c a t o r (Irregular heartbeat indicator) Heart Mark Battery Cover 1.5V Batteries (LR6, R6P or AA) Battery Compartment Display Air Connector Plug Air Socket Arm Cuff DC Jack START Button ...

  • A&D BT-Ci - page 7

    English 5 Symbols Symbols Function / Meaning Recommended Action Standby and power on. Battery installation guide Direct current Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appears while measurement is in progress. It blinks when the pulse is detected. Measurement is in pr ...

  • A&D BT-Ci - page 8

    English 6 Symbols Function / Meaning Recommended Action Date of manufacture Class II device WEEE label Refer to instructio n manual/booklet SN Serial number Polarity of DC jack Using the Monitor Inst alling / Changing the Batteries 1. Slide the battery cover up to open it. 2. Remove the used batteries and insert new batteries into the battery compa ...

  • A&D BT-Ci - page 9

    English 7 Using the Monitor Wireless Function CAUTION In the unlikely event that this monit or causes radio wave interference in a different wireless station, change the lo cation where this moni tor is used or stop use immediately. Be sure to use in a location where vi sibility between the tw o devices that you want to connect is good. The connect ...

  • A&D BT-Ci - page 10

    English 8 Using the Monitor Pairing / Unp airing A Bluetooth device needs to be paired with a different specific device in order to communicate with that device. If this monitor is paired with a receiver device from the start, measurement data is tran smitted automatically to the receiver device each time a measurement is made. Unpairing needs to b ...

  • A&D BT-Ci - page 11

    English 9 Using the Monitor Unpairing procedure 1 . Press and hold the START button until “ upr ” is displayed. 2 . Press the START butt on again. Unpairing will be performed. 3. The monitor displays “ end ” ” to indicate that unpairing is complete. When two receiver devices are paired, both devices are unpaired. 4. If “ err10 ” or ? ...

  • A&D BT-Ci - page 12

    English 10 Using the Monitor Selecting the Correct Cuff Size Using the correct cuff size is important for an accurate re ading. If the cuff is not the proper size, the reading may yield an incorrect blood pressure value. The arm size is printed on each cuff. The index and proper fit range, on the cuff , tell you if you are applying the correct cuff ...

  • A&D BT-Ci - page 13

    English 11 Do not roll up sh irtsleeve tightl y 1 to 2 cm A ir hose Cuff Inde x and Proper fit range A rtery position mark Secure the fabric fastener firmly Using the Monitor Applying the Arm Cuff 1. Wrap the cuff around the upper arm, about 1-2 cm above the inside of the elbow, as shown. Place the cuff directly against the skin, as clothing may ca ...

  • A&D BT-Ci - page 14

    English 12 Measurement s Model UA-767 BT-Ci is designed to dete ct the pulse and to inflate the cuff to a systolic pressure level automatically. If your systolic pressure is expec ted to exceed 230 mmHg or you use the optional small cuff, read "Measurem ent with the desired systolic pressure" on the next page. Normal Measurement 1. Place ...

  • A&D BT-Ci - page 15

    English 13 Measurements Measurement with the Desired Systolic Pressure If your systolic pressure is expect ed to exceed 230 mmHg or you use the optional small cuff, use this procedure. 1 . P l a c e t h e c u f f o n t h e arm (preferably the left arm). 2. Press and hold the START button until a number about 30 to 40 mmHg higher than your expected ...

  • A&D BT-Ci - page 16

    English 14 What is an Irregular Heartbeat Model UA-767 BT-Ci blood pressure moni tor provides a blood pressure and pulse rate measurement ev en when an irregular heartbeat occurs. An irregular heart beat is defined as a heart beat that varies by 25% from the average of all heart beats during the blood pressure measurement. It is important that you ...

  • A&D BT-Ci - page 17

    English 15 Reference Material: Journal of Hyperte nsion 1999, Vol 17 No.2 mmHg 110 105 100 95 90 85 80 Optimal 120 130 140 150 160 170 180 Systolic blood pressure mmHg Normal High-normal Grade 1 hypertension (mild ) Grade 2 hypertension (mode rate) Grade 3 hypertension (severe) Diastolic blood pressure About Blood Pressure What is Blood Pressure? B ...

  • A&D BT-Ci - page 18

    English 16 Typical fluctuation within a day (Measured every five minutes) PM AM Time Blood pressure Systolic Diastolic Sleep described in this manual to get to know your normal blood pressure. R egular readings give a more comprehensive bl ood pressure history. Be sure to note date and time when recording your blood pressure. Consult your doctor to ...

  • A&D BT-Ci - page 19

    English 17 Maintenance Do not open the device. It uses delicate electrical components and an intricate air unit that could be da maged. If you cannot fix the problem using the troubleshooting instructi ons, request service from your dealer or from the A&D service group. The A&D service group will provide technical information, spare part s ...

  • A&D BT-Ci - page 20

    English 18 Useful life Device: 5 years (when used six times a day) Cuff: 2 years (when used six times a day) Accessory AC adapter The adapter is to connect the blood pressure monitor to a power source at home. TB-233 Please contact your local A&D dealer for purchasing. The AC adapter is required to be inspected or replaced periodically. TB-233C ...

メーカー A&D カテゴリー Blood Pressure Monitor

A&D BT-Ciのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BT-Ciの取扱説明書
- A&Dの製品カード
- パンフレット
- またはA&D BT-Ciの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、A&D BT-Ciの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、A&D BT-Ciの取り付け説明書、サービスマニュアル、簡易説明書、またはA&D BT-Ciのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、A&D BT-Ciの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

A&D BT-Ciデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがA&D BT-Ciを使用するのを助ける技術的文書のことです。説明書は通常、全てのA&D BT-Ciユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

A&Dの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. A&D BT-Ciの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははA&D BT-Ciの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。A&D BT-Ciに関してこのドキュメントで見つけることができる全てのヒントの目次
3. A&D BT-Ciデバイスの基本機能を使うにあたってのヒント。 A&D BT-Ciのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。A&D BT-Ciに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるA&D BT-Ciのメーカー/サービスへの連絡先に関する情報。

A&D BT-Ciについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもA&D BT-Ciの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがA&D BT-Ciで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)