  • Desa VGL450P - page 1

    Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL B-VENT DECORA TIVE GAS FIREPLACE ® ® VGL450N (NA TURAL) AND VGL450P (PROP ANE/LP) This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of re ...

  • Desa VGL450P - page 2

    2 105704 VENTED TYPE DECORA TIVE APPLIANCE VGL450 Series ® 29 1 / 2 " 19" 4" DIA. 4 1 / 2 " 36" 33" 12 3 / 4 " 4 1 / 2 " 24" 32" 33 5 / 8 " 5/8" 3/4" 2" 2 7 / 8 " HEARTH DIMENSIONS 23 3 / 4 " 7 1 / 2 " 25 3 / 8 " 14" 10" 17" 24" 21 7 / 8 & ...

  • Desa VGL450P - page 3

    3 105704 OWNER’S MANUAL Model VGL450 series is a radiant heat deco- rative gas appliance that uses a millivolt gas control valve and a pilot ignition system. This appliance requires a 4" B-1 type vent- ing system. 4" B-1 type vent NOT supplied by DESA. Check with your "B" vent instructions for installation guidelines. This app ...

  • Desa VGL450P - page 4

    4 105704 VENTED TYPE DECORA TIVE APPLIANCE VGL450 Series ® CLEARANCES Minimum clearances to combustibles are: • Back and sides of outer surround: ..................... 0" min. • Drywall to sides of front face: ............................. 0" min. • "B" V ent surfaces: .................... 1" min. • Ceiling to open ...

  • Desa VGL450P - page 5

    5 105704 OWNER’S MANUAL Proceed to secure appliance to prepared framing at nailing flanges located at the sides of the appliance as shown in Figure 11. Figure 11 - Attaching Fireplace to Wall Studs VENTING INST ALLA TION A 4" B-1 Type Gas Vent Pipe is a double wall, unitized venting system (not supplied) which must be installed during the ro ...

  • Desa VGL450P - page 6

    6 105704 VENTED TYPE DECORA TIVE APPLIANCE VGL450 Series ® WALL SWITCH INSTALLATION The installation of a wall switch in this appliance allows you to activate the gas control valve without the use of normal current. CAUTION: Do not wire this millivolt system wall switch to a regular power supply. 1. Remov e access panel from lo wer front face. 2. ...

  • Desa VGL450P - page 7

    7 105704 OWNER’S MANUAL GAS SUPPLY TESTING Note: This section is intended as a guide for qualified technicians installing gas to this appliance. Do not connect appliance before pressure testing gas piping. Damage to gas valve may result and an unsafe condition may be caused. IMPORTANT: The appliance and its indi- vidual shut-off valve must be dis ...

  • Desa VGL450P - page 8

    8 105704 VENTED TYPE DECORA TIVE APPLIANCE VGL450 Series ® Figure 20 - Gas Connection Before connecting the flexible gas line to the gas control valve, a sediment trap must be included between them. It must extend down 3 inches beyond the center of the pipe (See Figure 20). Prepare incoming approved gas line with teflon tape or pipe joint compound ...

  • Desa VGL450P - page 9

    9 105704 OWNER’S MANUAL OPERA TING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follo w these instructions ex ...

  • Desa VGL450P - page 10

    10 105704 VENTED TYPE DECORA TIVE APPLIANCE VGL450 Series ® OPERA TING GUIDELINES AND MAINTENANCE INSTRUCTIONS Do not use this appliance if any part has been under water. Immediately call a quali- fied service technician to inspect the appli- ance and to replace any part of the control system and any gas control which has been under water. When li ...

  • Desa VGL450P - page 11

    11 105704 OWNER’S MANUAL TECHNICAL SER VICE You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Tech- nical Service Department at 1-800-323- 5190. You can also visit DESA International’s Technical Services web site at www.desatech.com. SER VICE HINTS When Gas Pressure Is Too ...

  • Desa VGL450P - page 12

    12 105704 VENTED TYPE DECORA TIVE APPLIANCE VGL450 Series ® TROUBLESHOOTING The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control v alve f ilter OBSERVED PROBLEM Cannot light pilot Pilot will not stay lit No gas to burner, although wall switch and ...

  • Desa VGL450P - page 13

    13 105704 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot re ...

  • Desa VGL450P - page 14

    14 105704 VENTED TYPE DECORA TIVE APPLIANCE VGL450 Series ® ACCESSORIES AND REPLACEMENT PA R T S RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC SERIES For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control. HEAT LIMIT SWITCH 14116 (105739-01) Should the limit switch need replacing, have a qualified te ...

  • Desa VGL450P - page 15

    15 105704 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Desa VGL450P - page 16

    LIMITED WARRANTY B-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill ...

メーカー Desa カテゴリー Indoor Fireplace

Desa VGL450Pのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VGL450Pの取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa VGL450Pの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa VGL450Pの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa VGL450Pの取り付け説明書、サービスマニュアル、簡易説明書、またはDesa VGL450Pのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa VGL450Pの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa VGL450Pデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa VGL450Pを使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa VGL450Pユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa VGL450Pの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa VGL450Pの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa VGL450Pに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa VGL450Pデバイスの基本機能を使うにあたってのヒント。 Desa VGL450Pのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa VGL450Pに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa VGL450Pのメーカー/サービスへの連絡先に関する情報。

Desa VGL450Pについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa VGL450Pの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa VGL450Pで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)