— 1 — EC 1 0SB (SL) EC 12 MODEL INSTRUCTION MANUAL AND SAFETY INSTRUCTIONS FOR AIR COMPRESSOR EC 10SB(SL) EC 12 W ARNING Improper and unsafe use of this compressor can result in death or serious bodily injury! This manual contains important information about product safety. Please read and understand this manual before operating the compressor. ...
-
InFocus EC 10SB (SL) - page 2
— 2 — — CONTENTS — Page IMPORTANT INFORMATION ............................... 2 MEANINGS OF SIGNAL WORDS ........................ 2 SAFETY IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE COMPRESSOR ........ 3 REPLACEMENT PARTS ........................................ 5 GROUNDING INSTRUCTIONS ............................ 5 EXTENSION CORD ...... ...
-
InFocus EC 10SB (SL) - page 3
— 3 — SAFET Y IMPOR T ANT SAFETY INS TRUCTIONS FOR USE OF THE COMPRESSOR W ARNING: Death or serious bodily injury could result from improper or unsafe use of compressor. To avoid these risks, follow these basic safety instructions: READ ALL INSTRUCTIONS 1. NEVER TOUCH MOVING PARTS. Never place your hands, fingers or other body parts near the co ...
-
InFocus EC 10SB (SL) - page 4
— 4 — 16. CHECK DAMAGED PARTS AND AIR LEAK. Before further use of the compressor, a guard or other part is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, air leak, and any other conditions ...
-
InFocus EC 10SB (SL) - page 5
— 5 — 33. THE SAFETY VALVE MUST WORK PROPERLY. Risk of bursting. Before starting the compressor pull the ring on the safety valve to make sure the valve moves freely. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion. GROUNDING INS TRUCTIONS This compressor should be grounded whi ...
-
InFocus EC 10SB (SL) - page 6
— 6 — EXTENSION CORD Use only three-wire extension cords that have three-prong grounding-type plugs and three-pole receptacles that accept the compressor’s plug. Replace or repair damaged cord. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product wi ...
-
InFocus EC 10SB (SL) - page 7
— 7 — OPERA TION AND MAINTENANCE NOTE : The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor. Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own compressor. NAME OF P ARTS Pressure gauge (B) indicates t ...
-
InFocus EC 10SB (SL) - page 8
— 8 — PRIOR T O OPERA TION 1. Power source Ensure that the power source to be utilized conforms to the power source requirements specified on the product nameplate. 2. Power switch Ensure that the knob of the pressure switch is in the “OFF” position (Fig. 2). If the plug is connected to a receptacle while the knob is in the “ON” positio ...
-
InFocus EC 10SB (SL) - page 9
— 9 — 4. Confirm the power receptacle If the power receptacle only loosely accepts the plug, the receptacle must be repaired. Contact the nearest electric store for repair service. If such a faulty receptacle is used, may cause overheating, resulting in a serious hazard. 5. Dipstick insertion and oil level check (If your compressor is EC10SB(SL ...
-
InFocus EC 10SB (SL) - page 10
— 10 — Fig. 5 3. Shutdown ( 1 ) Push the knob of the pressure switch to “ O FF ” ( Refer to Fig. 1 and Fig. 2) . (2) Unplug the plug from power source. (3) Open the drain cock located at the lower part of the tank (Fig. 6). MAINTENANCE W ARNING: Disconnect the compressor from the power source and remove the compressed air from the air tank ...
-
InFocus EC 10SB (SL) - page 11
— 11 — Fig. 8 Pour oil into the hole of the dipstick. To the level indicated on the dipstick (Refer to Fig. 4). For oil replacement, follow the table below. OIL TYPE SAE 5W50 SYNTHETIC OIL (–20°+120°F) For both summer and winter use SAE 10W40 MULTI-GRADED OIL (+50° + 120°F) For warm weather use only (2) Check the oil level of the pumping ...
-
InFocus EC 10SB (SL) - page 12
— 12 — ...
-
InFocus EC 10SB (SL) - page 13
— 13 — Item No. Code No. P ar t Name Q’ty Ref erence No. 1 Joint 1 7084080000 2 Screw 4 7011220000 3 Screw 1 7014300000 4 Washer 1 7030780000 5 Head 1 7570550000 6 Filter plate 1 7458340000 7 Intake filter 1 4085010000 8 Screw 1 7012010000 9 Set of gaskets 1 4085100000 10 Monoplate 1 4200020000 11 Conrod-cylinder kit 1 4190350000 12 Bearing 1 ...
-
InFocus EC 10SB (SL) - page 14
— 14 — ...
-
InFocus EC 10SB (SL) - page 15
— 15 — Item No. Code No. P ar t Name Q ’ ty Ref erence No. 1 Screw 1 7012010000 2 Intake filter 1 7210430000 3 Filtering element 1 7210010000 4 Filter plate 1 7458340000 5 Joint 1 7084190000 6 Set of gaskets 1 4082200000 7 Cylider 1 7575070000 8 Piston rings 1 4080020000 9 Piston pin 1 7050020000 10 Ring 2 7041010000 11 Con rod 1 5150150008 1 ...
-
InFocus EC 10SB (SL) - page 16
— 16 — ...
-
InFocus EC 10SB (SL) - page 17
— 17 — ...
-
InFocus EC 10SB (SL) - page 18
312 Code No. C99128411 Printed in Italy Hitachi Koki Co., Ltd. ...
InFocus EC 10SB (SL)についてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもInFocus EC 10SB (SL)の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがInFocus EC 10SB (SL)で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。