Aico RFDの取扱説明書

28ページ 1.67 mb
ダウンロード

ページに移動 of 28

Summary
  • Aico RFD - page 1

    A Guide to Residential Fir e Detection With Reference to BS 5839: Pt.6: 2004 Ahead on Quality Ahead on Perf ormance Ahead on F eatur es (68.52) X ...

  • Aico RFD - page 2

    2 Ei ELECTRONICS - THE MANUF A CTURER Ei Electronics is Eur ope’s lar gest and most experienced manuf acturer of residential smoke and heat alarms . The company has built up a wealth of experience o ver more than 30 years and is now b y f ar the UK’s leading supplier of smok e alar ms f or residential use, as well as the f ir st choice supplier ...

  • Aico RFD - page 3

    recommendations of BS 5839: Pt.6 more clearly under stood, and to of fer advice on how to design, install and maintain a system that meets the requirements, with reference to the 2004 amendments. At the same time, this guide is designed to help answer the most commonly asked questions about fire detection; f or example, ‘which types of detector t ...

  • Aico RFD - page 4

    4 Further evidence of the vital importance of smoke alarms comes from American studies. In American States where residential f ire protection is m andator y , some 92% of homes have the required f ire alarm systems . 50% of ALL the f ire deaths which occur ha ppen within the 8% where no alarms are fitted. BS 5839: Pt.6: 2004 itself says: “It has ...

  • Aico RFD - page 5

    5 THE ESSENTIAL CHANGES T O BS 5839: Pt.6: 2004 – A T A GLANCE THE DOCUMENT ITSELF Each clause of the document is now split into 2 parts . Firstly , there is the commentar y – in italics – this sets out the reasoning behind what at first sight may appear to be arbitrar y recommendations. The recommendations are in normal type, so it is quite ...

  • Aico RFD - page 6

    6 SYSTEM V ARIA TIONS Where a modif ication to a system is made, the standard now refers to it as a ‘V ariation’ r ather than a ‘Deviation’, as the latter term implied that the system w as in some way inf erior . Note that, in cases where a variation from the recommendations is proposed, the system certificate has to be signed and agreed by ...

  • Aico RFD - page 7

    7 BS 5839: Pt.6 - AN INTRODUCTION BS 5839: Pt.6 is not intended f or householders themselves, but to pro vide guidance and recommendations f or architects and other building prof essionals, enf orcing authorities , contractors and other s responsible f or implementing f ire precautions in buildings. The Code of Practice should not be quoted as if i ...

  • Aico RFD - page 8

    8 On the other hand, a low f ire risk may not justify the cost, complexity and extent of such a system. For example, the single occupant of a small bung alow might be adequately protected b y the installation of one mains po wered smok e alar m, w hereas the risk to w hich f amilies in a six storey house in multiple occupation are exposed w ould wa ...

  • Aico RFD - page 9

    Fires caused by electrical appliances account f or some 10% of all household f ires, but result in only 6% of deaths . Electric blankets and bed w ar mer s cause 40% of all the deaths in f ires due to f aulty electrical appliances . The Code says that ‘use of electric blankets, par ticular ly by high risk groups such as the elderly , increases th ...

  • Aico RFD - page 10

    10 People with impaired mobility require more time to escape. They need the earliest possible warning of a fire and greater alarm cover age. The hear ing impaired also have v er y particular needs, and these are dealt with later in this document. It is obvious to an y landlord - in the public or private sector - that those judged to be most at risk ...

  • Aico RFD - page 11

    SYSTEM PLANNING BS 5839: Pt.6 quite reasonably points out that, no matter how good the system is, people will only hav e an adequate chance of escape if there are enough detectors installed and if the alarms can successfully rouse them from sleep. SILENCING & DISABLEMENT The Code is very aware of the grav e danger posed by tampering with alarms ...

  • Aico RFD - page 12

    12 equipment to BS EN 54-2, and power supply to BS EN 54-4, installed to BS 5839: Pt.1 with some minor exceptions • Grade B - Fire detection and alar m system comprising fire detectors (other than smoke alarms), fire alarm sounders and control and indicating equipment to either BS EN 54-2 (and pow er supply to BS EN 54-4), or to Annex C of BS 583 ...

  • Aico RFD - page 13

    and principal living room (smoke detectors are an accepta ble alternative in the living room). Existing Properties Single storey - owner occupied Grade F , Categor y LD3 Grade E should be installed if there is doubt regarding the ability of the occupier to replace batteries , or Grade D if the reliability of the mains pow er supply is suspect. Sing ...

  • Aico RFD - page 14

    14 The Code also looks at a third type of alarm - heat. More emphasis is placed upon the use of heat alarms than previously . The Code recommends that they should comply with BS 5446: Pt.2 and suggests they be used where nuisance alarms from other sensor types are a concern. In new build pr operties heat alarms are now recommended both in the kitch ...

  • Aico RFD - page 15

    P ositioning of Smoke Alar ms: There are a number of f actors one has to take into consider ation when positioning and maintaining a smoke alarm. The design and occupation of the premises will obviously be one of the inf luencing f actors in deciding w here to position the units as well as the likely types of f ire and also the maintenance required ...

  • Aico RFD - page 16

    16 In the ev ent of a f ire being detected, a small vibr ating pad located beneath the sleeper’s pillo w gently alerts them. At the same time a pow erful strobe light f lashes to pro vide a fur ther visual warning. Devices such as these are no w increasingly cited as important considerations and should be considered as a matter of course in appli ...

  • Aico RFD - page 17

    operation, testing, m aintenance, f alse alarms , escape plans and siting. TESTING AND MAINTENANCE Regular routine testing and m aintenance is very impor tant and should be considered at the design stage. The Code states that the user has a responsibility f or routinely testing the system and should be supplied with simple instructions on how to do ...

  • Aico RFD - page 18

    18 It is clear that installing a batter y pow ered smoke alarm unit and thinking that it is suf ficient to pr otect the tenant is an outdated notion. Moreover , ev en mains po wered systems without a reliable long ter m stand-by cannot be relied upon to pro vide adequate protection, as landlords cannot guarantee that tenants will ne ver hav e their ...

  • Aico RFD - page 19

    19 • Do not locate unit within 1m of dimmer controlled lights and wiring - some dimmers can cause interference • Do not wire into the same cir cuit as a dimmer • Do not locate unit within 1.5m, or route wiring within 1m of fluorescent light f ittings as electrical “noise” and/or f lickering may af fect the unit. Do not wire into the same ...

  • Aico RFD - page 20

    20 • Hush button for f alse alar m control • Interconnects with other Ei Prof essional mains po wered smok e and heat alar ms • Separate mains and w ar ning LEDs • T ime and money saving Easi-f it design • 5 year guarantee • Kitemarked to BS 5446: Pt.1: 2000 Ei144 Heat With Hush • Ideal f or protecting kitchens and areas where smoke a ...

  • Aico RFD - page 21

    insect resistant screen • Separate mains and w ar ning LEDs • Hush button for f alse alar m control • Low pow er cell warning in the ev ent of a mains or cell f ailure • Precision charging circuit ensures peak cell perf ormance • Prov en 10 year+ rechargeable lithium cell back-up • Kitemarked to BS 5446: Pt.1: 2000 DISPOSAL All ionisati ...

  • Aico RFD - page 22

    22 • Fitted with rechar geable lithium cells to last in excess of 10 yrs • Up to tw elve alar ms on one system • Pr ogrammable repeater function f or more dif ficult applications • Wide range of compatible accessories RADIOLINK ANCILLARY PRODUCTS Ei428 Remote Relay Module • Mains pow ered • Easy to install • For use with 140 and 160 s ...

  • Aico RFD - page 23

    23 ANCILLARY FIRE DETECTION PRODUCTS ALARM SYSTEMS FOR THE HEARING IMP AIRED Residents with hearing dif f iculties require a dif ferent approach to f ire protection. The Ei Pr ofessional Alarm for the hearing impaired is currently the only unit on the market m ade by an experienced smoke alarm manuf acturer . Comprising a powerful str obe light and ...

  • Aico RFD - page 24

    MCP400 Manual Call P oint • For use with Ei151TLR, Ei156TLR, Ei161R, Ei164R or Ei166R alarms • Supplied complete with surface mount box • T esting key supplied • Supplied with non-breaka ble operating element • Suita ble f or use with Modifire • LPC a ppro ved, conf or ms to BS EN 54-11 Ei159 Smoke Alar m Locator Switch This conv enient ...

  • Aico RFD - page 25

    Ei152 Remote T est & Hush Switch The Remote T est and Hush Switch is specif ically designed f or use with the Ei151TLR, Ei156TLR, Ei161R, Ei164R or Ei166R alarms . • T ests alar ms or silences false alarms (only on ‘R’ models in the system) without the need to reach the alarm itself • Ideal for the inf ir m or elder ly • W all mounted ...

  • Aico RFD - page 26

    26 9 V olt Alar ms With 10 y ear+ Life Lithium Batter y Cells Both of these alarms are supplied with tamper -resistant, non-replacea ble 10 year lif e lithium batter y cells to meet the requirements f or a BS 5839: Pt.6, Grade F system f or single storey tenanted properties. Ei100TYC- Ionisation with 10 year+ lif e Lithium batter y , false alarm &a ...

  • Aico RFD - page 27

    27 Ei SMOKE ALARMS - THE FIRST CHOICE FOR LOC AL A UTHORITIES AND HOUSING ASSOCIA TIONS NA TIONWIDE Ei Prof essional smoke alarms and ancillar y products hav e been specif ied by liter ally hundreds of Local Authorities and Housing Associations in England, Scotland, W ales and Norther n Ireland as the products of choice f or their retrof it program ...

  • Aico RFD - page 28

    Aico Ltd, Mile End Business Park, Maesbur y Road, Oswestr y , Shropshire SY10 8NN T el: 0870 758 4000 Fax: 0870 758 4010 • Sales - T el: 0870 758 4001 Fax: 0870 758 4011 e-mail: enquiries@aico.co.uk • www .aico.co.uk E & OE As our policy is one of continuous de velopment, we reserve the right to amend designs and specifications without prio ...

メーカー Aico カテゴリー Smoke Alarm

Aico RFDのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RFDの取扱説明書
- Aicoの製品カード
- パンフレット
- またはAico RFDの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Aico RFDの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Aico RFDの取り付け説明書、サービスマニュアル、簡易説明書、またはAico RFDのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Aico RFDの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Aico RFDデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAico RFDを使用するのを助ける技術的文書のことです。説明書は通常、全てのAico RFDユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Aicoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Aico RFDの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAico RFDの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Aico RFDに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Aico RFDデバイスの基本機能を使うにあたってのヒント。 Aico RFDのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Aico RFDに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAico RFDのメーカー/サービスへの連絡先に関する情報。

Aico RFDについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAico RFDの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAico RFDで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)