    Questions? Help is just a moment away! Call: Generator Helpline 877-369-9400 Monday-Friday 8:00 AM to 5:00 PM Central Time Generator Systems Installation Manual GEN20AD-E GEN16AD-E GEN15ADC-E ...

  • Rheem GEN20AD-E - page 2

    Thank you for purchasing this quality-built Rheem / Ruud standby generator. We are pleased that you’ve placed your confidence in the Rheem or Ruud brand. When operated and maintained according to the instructions in this manual, your Rheem / Ruud generator will provide many years of dependable service. This manual contains safety information to m ...

  • Rheem GEN20AD-E - page 3

    3 Table of Contents Important Safety Instructions ........................ 4 Installation .................................... 7 Owner Responsibilities ......................................... 7 Installing Dealer/Contractor Responsibilities ........................ 7 Cold Weather Kit ............................................. 7 Unpacking Precau ...

  • Rheem GEN20AD-E - page 4

    4 Save These Instructions WARNING Running engine gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide could result in death, serious injury, headache, fatigue, dizziness, vomiting, confusion, seizures, nausea or fainting. t Operate this product ONLY outdoors in an area that will not accumulate deadly exhaust g ...

  • Rheem GEN20AD-E - page 5

    5 WARNING Generator produces hazardous voltage. Failure to properly ground generator could result in electrocution. Failure to isolate generator from utility power could result in death or serious injury to electric utility workers due to backfeed of electrical energy. t When using generator for backup power, notify utility company. t DO N ...

  • Rheem GEN20AD-E - page 6

    6 WARNING Starter and other rotating parts could entangle hands, hair, clothing, or accessories resulting in serious injury. t NEVER operate generator without protective housings, covers, or guards in place. t DO NOT wear loose clothing, jewelry or anything that could be caught in the starter or other rotating parts. t Tie up long hair and ...

  • Rheem GEN20AD-E - page 7

    7 Installation Equipment Description This product is only for use as an optional generator system which provides an alternate source of electric power and to serve loads such as heating, refrigeration systems, and communication systems that, when stopped during any power outage, could cause discomfort or inconvenience. NOTICE This product does NOT ...

  • Rheem GEN20AD-E - page 8

    8 Unpacking Precautions The unit is shipped ready for installation. Avoid damage from dropping, bumping, collision, etc. Store and unpack carton with the proper side up, as noted on the shipping carton. Delivery Inspection After removing the carton, carefully inspect the generator for any damage that may have occurred during shipment. If loss or da ...

  • Rheem GEN20AD-E - page 9

    9 Installation Checklist Carbon Monoxide (CO) Detector Carbon Monoxide (CO) detector installed and in working order . Smoke detector(s) installed and in working order . Placement Required permits have been obtained. Generator placed in an area free from Carbon Monoxide (CO) buildup. See Placement of Standby Generator to Reduce the Risk of Carbon Mo ...

  • Rheem GEN20AD-E - page 10

    10 Intentionally Left Blank ...

  • Rheem GEN20AD-E - page 11

    11 Generator Placement Before installing generator, consult with home owner and convey the following requirements, which must be satisfied before the installation is complete. There are two equally important safety concerns in regards to carbon monoxide poisoning and fire. There are also several general location guidelines that must be met before t ...

  • Rheem GEN20AD-E - page 12

    12 All fossil fuel burning equipment, such as standby generators, contains carbon monoxide (CO) gas in the engine exhaust. CO gas is odorless, colorless and tasteless and is unlikely to be noticed until a person is overcome. CO gas can kill you so it is required that the following is included as part of the installation:  t *OTUBMM HFOFSBU ...

  • Rheem GEN20AD-E - page 13

    13  t %JSFDU UIFTUBOECZ HFOFSBUPS FYIBVTU BXBZ GSPN PS parallel to the building or structure. DO NOT direct the generator exhaust towards a potentially occupied building, structure, windows, doors, ventilation intakes, soffit vents, crawl spaces, open garage doors or other openings where exhaust gas could accumulate an ...

  • Rheem GEN20AD-E - page 14

    14 Placement of Standby Generator to REDUCE THE RISK OF FIRE Requirements: NFP A 37 2010, section 4. 1. 4, Engines Located Outdoors. Engines, and their weatherproof housings if provided, that are installed outdoors shall be located at least 1.5m (5 ft) from openings in walls and at least 1.5 m (5 ft) from structures having combustible walls. A mini ...

  • Rheem GEN20AD-E - page 15

    15 A Standby weatherproof enclosure must be at least 5 ft (1.5 m) from windows, doors, any wall opening, shrubs or vegetation over 12 inches (30.5 cm) in height. B Exhaust outlet side of weatherproof enclosure must have at least 5 ft (1.5 m) minimum clearance from any structure, shrubs, trees or any kind of vegetation. C Standby weatherproof enclos ...

  • Rheem GEN20AD-E - page 16

    16 Electrical and Fuel Inlet Locations The 3/4 inch N.P .T . fuel inlet connector ( A ) and electrical inlet location ( B ) is shown below . A ½ inch knock-out is provided for the electrical inlet. This inlet may be enlarged or supplemented to accommodate a maximum conduit size of 1 ½ inches. Ensure that the installed conduit(s) enter the unit in ...

  • Rheem GEN20AD-E - page 17

    17 Lifting the Generator The generator weighs more than 500 pounds (227 kg). Proper tools, equipment and qualified personnel should be used in all phases of handling and moving the generator . 5 XPwMFOHUITPGwOPNJOBMNJOJNVNTDIFEVMFE steel pipe ( A ), supplied by the installer , are required to lift ...

  • Rheem GEN20AD-E - page 18

    18 Access Ports The generator is equipped with an enclosure that has several access panels, as shown. The access panels and the components located behind them are listed below: A - Roof (Control Panel, air filter, oil dipstick, and circuit breaker) B - Front Access Panel (oil drain and oil filter) C - Battery Panel (battery and generator data label ...

  • Rheem GEN20AD-E - page 19

    19 To open roof: 1. Insert key into lock ( A ) of front panel. Gently push down on roof above the lock to aid in turning the key. Turn key one quarter turn clockwise. 2. Lift roof to the open position. To remove front panel: 1. Remove the two bolts ( B ) that secure the panel to the unit. 2. Lift panel to remove from unit. To secure front panel: 1. ...

  • Rheem GEN20AD-E - page 20

    20 The Gaseous Fuel System The information below is provided to assist gaseous fuel system technicians in planning installations. In no way should this information be interpreted to override applicable fuel gas codes. Consult with your local fuel supplier or Fire Marshall if questions or problems arise. TO THE INST ALLER: Consult with the generator ...

  • Rheem GEN20AD-E - page 21

    21 Fuel Consumption Estimated fuel supply requirements at half and full load for natural gas and LP vapor fuels are shown below. LP Vapor (Propane) 20kW 17kW 15kW Full Load Cu Ft/Hr 135 118 109 Gal/Hr (liquid) 3.75 3.28 3.03 BTU/Hr 337500 295000 272500 3/4 Load Cu Ft/Hr 109 99 90 Gal/Hr (liquid) 3.03 2.75 2.5 BTU/Hr 272500 247500 225000 1/2 Load Cu ...

  • Rheem GEN20AD-E - page 22

    22 Fuel Conversion The engine of your generator system is factory calibrated to run on natural gas (NG) or on liquefied petroleum (LP) vapor. To convert to either fuel, follow these steps: NOTICE Units are set to NG at the factory. 1. Insert key into lock of front panel. Gently push down on roof above the lock to aid in turning the key. Turn key on ...

  • Rheem GEN20AD-E - page 23

    23 System Connectors Low Voltage connections to signal fault contacts, transfer switch communication and auxiliary 12VDC power are made via a field connection terminal block in control board area. Compare this illustration with your generator to familiarize yourself with the location of these connections. A - Two Pin Terminal Block — Used to conn ...

  • Rheem GEN20AD-E - page 24

    24 Generator AC Connection System A single-phase, three-wire AC connection system is used in the home generator. The stator assembly consists of a pair of stationary windings with two leads brought out of each winding. The junction of leads 22 and 33 forms the neutral lead, as shown schematically and as a wiring diagram. A complete schematic and wi ...

  • Rheem GEN20AD-E - page 25

    25 Grounding the Generator The home generator must be installed as part of a system that includes a listed transfer switch, with neutral to ground bonding at the transfer switch in accordance with installation instructions. Unless mandated by local code, additional grounding to earth at the generator is not required. Any grounding at generator must ...

  • Rheem GEN20AD-E - page 26

    26 System Control Panel The generator control panel, located inside the generator housing, is shown below. Brief descriptions of the controls used during installation are: The generator control board, located inside the generator, under the roof, is shown below. Brief descriptions of the controls used during installation are: A - Menu/Programming N ...

  • Rheem GEN20AD-E - page 27

    27 Menu MENU ENTER THE MENU (VIEW SETTINGS) PRESS TO CONFIRM SELECTION WHEN PROGRAMMING. ESCAPE (EXIT) RETURN TO LAST MENU ITEM RIGHT ARROW TOGGLE THROUGH MENU OPTIONS SETTING SYSTEM PARAMETERS LEFT ARROW TOGGLE THROUGH MENU OPTIONS SETTING SYSTEM PARAMETERS MANUAL MODE USED TO MANUALLY START THE GENERATOR. PRESS AND HOLD BUTTON TO START THE GENERA ...

  • Rheem GEN20AD-E - page 28

    28 NOTE: Date and T ime were set at the fac tory and stored in the control panel memor y . The Exercise C ycle was also set at the factor y . Th e default exercise cycle occurs on T u esdays, at 2 : 00 P .M. Central Standard Time . To updated or change these settings, follow the steps belo w. IF DURING PROGRAMMING NO BUT TONS ARE PRESSED FOR 30 SEC ...

  • Rheem GEN20AD-E - page 29

    29 A UT OMA TIC MODE GENERA TOR ON (When Gener ator R unning - Aut o Mode) GENERA TOR READ Y or SERVICE CODE DESCRIPTION (When Gener ator NO T Running - Auto Mode) Control Panel Prompts Automatic Mode In Automatic Mode, the display screen will display via scrolling text:  t (&/&3"503 3&"%:  JG UIF VOJU? ...

  • Rheem GEN20AD-E - page 30

    30 Advanced Settings Screen kW kW FLASHING 50/60 Hz FLASHING Hz PHASE VO LTS SOFTW ARE Ver sion Displayed VO LTS FLASHING SINGLE or THREE FLASHING E-Gov ernor Check Stepper Motor will sweep thr ough throttle range for dealer visual verication or or or or or or or or or or Advanced setting parameters are preset at the factory for a typical instal ...

  • Rheem GEN20AD-E - page 31

    31 Final Installation Considerations Engine Oil NOTICE Any attempt to crank or start the engine before it has been properly serviced with the recommended oil will result in equipment failure. t Refer to Maintenance in the operator’ s manual for oil fill information. t Damage to equipment resulting from failure to follow this instruction wil ...

  • Rheem GEN20AD-E - page 32

    32 Initial Start-up (No Load) The unit has been set-up for NG operation at the factory. Fuel conversion, if needed, must be completed prior to performing these steps. See Fuel Conversion . Before operating the home generator or placing it into service, inspect the entire installation carefully. Then begin testing the system without any electrical l ...

  • Rheem GEN20AD-E - page 33

    33 Electronic Governor System The engine electronic governor system allows for improved control and increased generator performance compared to mechanically governed systems. The result is smooth TUFBEZTUBUF PQFSBUJPO XJUIPVU UIFiIVOUJOHw DPNNPO UP many mechanical governors. The system also reduces speed variations under eng ...

  • Rheem GEN20AD-E - page 34

    34 Operation Automatic Operation Sequence The generator’s control board constantly monitors utility voltage. Should utility voltage drop below a preset level, the control board will signal the engine to crank and start. When utility voltage is restored above a preset voltage level, the engine is signaled to shut down. The actual system operation ...

  • Rheem GEN20AD-E - page 35

    35 Antenna Installation The supplied antenna must be installed before the wireless monitor will operate. 1. Insert key into lock of front panel. Gently push down on roof above the lock to aid in turning the key. Turn key one quarter turn clockwise. 2. Lift roof to the open position. 3. Carefully push out the plug ( A ) located on the inside of the ...

  • Rheem GEN20AD-E - page 36

    36 Wireless Monitor The generator is supplied with a battery-powered, wireless monitor. The monitor communicates wirelessly with the generator control panel. The monitor may be placed in a suitable location in the home. The system has a line-of-sight range of about 200 feet, but this distance will decrease if the signal has to pass through walls or ...

  • Rheem GEN20AD-E - page 37

    37 Wireless Monitor Operation 1. Remove battery access cover ( A ) on back of monitor and install 2 AA batteries. (Observe correct battery polarity which is embossed in the bottom of the battery compartment). Replace battery access cover. NOTICE The wireless monitor was linked to the generator at the factory. Communication will begin upon the insta ...

  • Rheem GEN20AD-E - page 38

    38 Standard Operation: Wireless Monitor Status LED’s  t 5IFXJSFMFTT NPOJUPS SFDFJWFT EBUB GSPN UIF HFOFSBUPS every 10 minutes and displays the generator status through 3 LED’s.  t 1SFTTJOH UIF SYSTEM UPDATE button will provide current generator status by flashing the status LED’s. When pressed, all 3 ...

  • Rheem GEN20AD-E - page 39

    39 Schematic Diagram Schematic / Wiring Diagrams LEGEND BW - Plug for Option a l B a t tery W a rmer CB - Ci rcuit Bre a ker CMA - Control Module Assembly COM - Common EW - Plug for Option a l Engin e Oil W a rmer FS - Fuel Solenoid GND - Ground IS - Idle Solenoid LOP - Low Oil Pressure Switch (Closes on Low Press ure) N.C. - Norm a lly Closed N.O. ...

  • Rheem GEN20AD-E - page 40

    40 LEGEND BW - Plug for Option a l B a ttery W a rmer CB - Circuit Bre a ker CMA - Control Module Assembly COM - Common EW - Plug for Option a l Engine Oil W a rmer FS - Fuel Solenoid GND - Ground IS - Idle Solenoid LOP - Low Oil Pressure Switch (Closes on Low Pressure) N.C. - Norm a lly Closed N.O. - Norm a lly Open OTS - Over T emper a ture Switc ...

メーカー Rheem カテゴリー Portable Generator

Rheem GEN20AD-Eのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GEN20AD-Eの取扱説明書
- Rheemの製品カード
- パンフレット
- またはRheem GEN20AD-Eの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Rheem GEN20AD-Eの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Rheem GEN20AD-Eの取り付け説明書、サービスマニュアル、簡易説明書、またはRheem GEN20AD-Eのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Rheem GEN20AD-Eの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Rheem GEN20AD-Eデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRheem GEN20AD-Eを使用するのを助ける技術的文書のことです。説明書は通常、全てのRheem GEN20AD-Eユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Rheemの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Rheem GEN20AD-Eの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRheem GEN20AD-Eの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Rheem GEN20AD-Eに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Rheem GEN20AD-Eデバイスの基本機能を使うにあたってのヒント。 Rheem GEN20AD-Eのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Rheem GEN20AD-Eに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問