Boca Research Adjustable MC Ghostの取扱説明書

27ページ 0.65 mb
ダウンロード

ページに移動 of 27

Summary
  • Boca Research Adjustable MC Ghost - page 1

    Users Manual Adjustable MC Ghost Ticket Printer Adjustable MC Ghost Ticket Printer ...

  • Boca Research Adjustable MC Ghost - page 2

    BOCA SYSTEMS, INC. © 1999 Boca Systems, Inc. All rights reser ved. Under the cop yright laws, this man ual ma y not be copied, in whole or in par t, without the written consent of BOCA. Ev er y eff or t has been made to ensure that the information in this manual is accurate. BOCA is not responsible f or printing or clerical errors and reser ves th ...

  • Boca Research Adjustable MC Ghost - page 3

    T able of Contents Page 1.0 Introduction 1 2.0 Unpacking the Printer 2 3.0 A tour of your printer 3-4 4.0 Installation 5 5.0 Configuration 6 6.0 Standard Interf ace Pinouts 7 7.0 Thermal P aper - Theor y and Specification 8 8.0 Maintenance and Adjustments 9-13 9.0 Spare P ar ts List 14 10.T roubleshooting Guide 15-16 ...

  • Boca Research Adjustable MC Ghost - page 4

    T able of Figures and Appendices Page Figure 1 P ackaging 2 Figure 2 Micro Ghost Tick et Pr inter 3 Figure 3 Side view with door open 3 Figure 4 Rear view 4 Figure 5 Side view with electronics e xposed 4 Figure 6 Tick et loading 5 Figure 7 Slider Adjustment 6 Figure 8 Optical De vices 10 Figure 9 Print head remov al 12 Appendix A Operator Menu opti ...

  • Boca Research Adjustable MC Ghost - page 5

    FCC NOTICE NO TE: The equipment has been tested and f ound to comply with the limits for a class A digital de vice, pursuant to par t 15 of the FCC rules. These limits are designed to provide reasonab le protection against har mful interference when the equipment is operated in a commercial en vironment. This equipment generates , uses, and can rad ...

  • Boca Research Adjustable MC Ghost - page 6

    W ARRANTY INFORMA TION PRINTERS - BOCA warr ants each printer to be free of defects f or a per iod of one year from the date of shipment when subject to nor mal use and ser vice. This w arranty cov ers all par ts and labor e xcept f or the print head which is warranted f or 90 days . All warr anty labor is to be perf or med at the BOCA f acility . ...

  • Boca Research Adjustable MC Ghost - page 7

    1.0 Introduction The BOCA Adjustable MC Ghost is a direct thermal tick et pr inter especially designed f or airline boarding pass and bagtag applications. The printer will automatically deter mine if a boarding pass or tag is loaded. T wo printers can be daisy chained together in order to print both passes and bag tags from a single host computer . ...

  • Boca Research Adjustable MC Ghost - page 8

    2.0 Unpacking the Printer The printer is shipped in a r uggedized container . Please sav e packing material for future use. Remov e the pr inter ( see figure 1 ) and accessories from the box and inspect f or obvious damage . If damage is noticed please repor t it immediately to BOCA. T el: (561) 998-9600 F ax: (561) 998-9609 The f ollowing items sh ...

  • Boca Research Adjustable MC Ghost - page 9

    3.0 A T our of Y our Printer Figure 2 - Micro Ghost tick et pr inter Figure 3 - Micro Ghost tick et pr inter 3 tick et output slot control panel Adjustment Knob Timing belt Drive Pulle ys Stepper Motor T ransf or mer LCD ...

  • Boca Research Adjustable MC Ghost - page 10

    Figure 4 - Micro Ghost - rear view Figure 5 - Micro Ghost - top view with electronics e xposed 4 Roll Stock Holder Main Logic Board A C connector On/Off s witch Tick et Entrance Slot Interf ace connector , Output to another printer (25 pin male) Interf ace connector , Input from Host to another printer (25 pin f emale) ...

  • Boca Research Adjustable MC Ghost - page 11

    4.0 Installation The Adjustable MC Ghost tic ket printer is designed to be mounted on a desktop or on a shelf . Pr ior to the site preparation and installation, the printer should be posered up and run in the self test mode. La y the printer flat on a counter as shown in figure 3 . V er ify that line voltage is the same as the line v oltage specifi ...

  • Boca Research Adjustable MC Ghost - page 12

    5.0 Configuration The Adjustable MC Ghost is f actor y configured f or a variety of customer requirements. 1. The printer has a resolution of 200dpi. 2. The printer has an adjustable paper path (see figure 7) 3. The printer has a ser ial interf ace f or input from the host or another printer (see figure 4), and a serial interface f or output to ano ...

  • Boca Research Adjustable MC Ghost - page 13

    6.0 Standard Interface Pinouts 6.1 Serial Pinouts RS232 (Standar d) Pin Function 2 Printer T ransmit 3 Printer Receive 7 Ground 5,20 DTR (Printer Ready) 4,22 R TS (+5Vdc) 25 pin to 9 pin Adapter 25 Pin Female 9 Pin Male 23 32 47 58 66 75 20 4 7 HOST COMPUTER OR TERMINAL PRINTER # 1 PRINTER # 2 Cable #1 9M 25 M Cable #2 9F 25 M 25F 25M 25F 25F-9M Pi ...

  • Boca Research Adjustable MC Ghost - page 14

    7.0 Thermal Paper - Theory & Specification The print head’ s lif e expectancy is composed of both a mechanical and an electrical component. Both of these f actors are strongly influenced by the quality of the thermal paper used. MECHANICAL The print head has a theoretical rating of 60 kilometers. This n umber is based upon the assumption that ...

  • Boca Research Adjustable MC Ghost - page 15

    8.0 Maintenance and Adjustments Y our tic k et pr inter is solidly constructed and has been designed for high v olume use. It requires minimal care to provide maxim um ser vice. This section provides an o v er view of printer maintenance, including par ts alignments, adjustment and replacement. F or discussion pur poses, the printer consists of two ...

  • Boca Research Adjustable MC Ghost - page 16

    The position of the tear can be controlled by changing the cut count setting in the OPERA T OR MENU (see Appendix A ). If you are not ab le get the desired tear position, then make sure y our tick et stock w as manuf actured to proper specifications. Once a month the opto ey e should be blown off with air to remo ve any accum ulated paper dust. A s ...

  • Boca Research Adjustable MC Ghost - page 17

    8.1.6 THERMAL PRINT HEAD The print head should be cleaned monthly , initially , to prev ent debr is from building up on the print element. The required cleaning inter val v aries greatly depending on the quality of the tick et stock and the amount of dust entering the pr int area. Excessive dir t build up on the print head will result in reduced qu ...

  • Boca Research Adjustable MC Ghost - page 18

    Figure 9a - Print Head remov al Figure 9b - Print Head remov al Figure 9c - Print Head remov al 12 ...

  • Boca Research Adjustable MC Ghost - page 19

    8.1.7 Rubber Drive Roller (Platen) The rubber drive roller should be cleaned once a y ear to pre vent paper dust from building up on the roller . Clean drive roller with a paper to wel and alcohol. 1. Lift up the cam lock assemb ly (located abov e the head mounting bloc k) to remove pressure from the ther mal head. (see figure 9a ) 2. Lift up the h ...

  • Boca Research Adjustable MC Ghost - page 20

    9.0 Spare Parts List DESCRIPTION P ART NUMBER A C Switch and pow er filter P31-1000 Belt, Timing 100T (200 dpi) P50-1011 Control P anel Assembly , FGL41 421671 Displa y P anel, FGL 41 (LCD) P38-1003 Fuse 1A SB (220v operation) P29-1007 Interf ace Board (25 pin F emale) 422190-6 SER Interf ace Board (25 pin Male) 422190-4 Logic Board FGL 41 Optical ...

  • Boca Research Adjustable MC Ghost - page 21

    10.0 T roubleshooting Guide This is a simplified troubleshooting guide listing some of the typical prob lems. It is not intended to provide technical details or repair methods , but can serve as a guide to f ault isolation in the field. If you need additional help , please contact BOCA at T el: (561) 998-9600 F ax: (561) 998-9609 1. NO OPERA TION, ...

  • Boca Research Adjustable MC Ghost - page 22

    5. ERRA CTIC PRINT POSITION a. See # 4 6. POOR PRINT OUT (light print out) a. Make sure the print head/cam lock assemb ly if fully loc ked in the closed position. b . Consult “Thermal Print Head” in Section 8.1.2 . c. Clean print head. Consult “Thermal Print Head” in Section 8.1.2 . d. Adjust print intensity setting via the control panel (s ...

  • Boca Research Adjustable MC Ghost - page 23

    Appendix A - Operator Menu Options This printer allows the user to adjust v arious pr inter options through the control panel. T o access and use the OPERA T OR MENU , f ollow these steps: 1. Tic ket stoc k should be loaded into the printer . 2. Press both MENU and TEST switches sim ultaneously f or about three seconds. The LCD window displa ys OPE ...

  • Boca Research Adjustable MC Ghost - page 24

    The char t below lists the present menu topics . These topics are subject to change. OPERA T OR MENU! B A UD RA TE? MINI/MICRO? PRINT SPEED? DIA GNOSTIC MODE? TICKET TYPE? ST A TUS ENABLED? TRANSP ARENT MODE P APER MODE? INC BPP CUT COUNT? DEC BPP CUT COUNT? INC BTP CUT COUNT? DEC BTP CUT COUNT? PRINT MODE? PRINT INTENSITY? EXIT AND SA VE JUST EXIT ...

  • Boca Research Adjustable MC Ghost - page 25

    MINI/MICR O? Defines the type of printer . MINI Is f or a printer with a Silent Cutter Assembly (SC2) ( Mini, Mini Plus, Mini MB , Dual Mini) MICR O Is f or a printer without a SC2 (Micro , Micro Ghost, Micro MB, Dual Micro) (factory default) PRINT SPEED? Controls the speed the tick et trav els at. Also eff ects the pr int quality . The numbers ran ...

  • Boca Research Adjustable MC Ghost - page 26

    P APER MODE? Is generally used only f or test pur poses. It may also be used on roll stoc k with no blac k mar ks on the tick et. Y our choices are YES (Enabled) or NO (Disab led). NO is factory default. INC BPP CUT COUNT? Enables the oper ator to mov e Boarding P ass tear position to the left (tow ards the tick et e xit area). Cut counts are incre ...

  • Boca Research Adjustable MC Ghost - page 27

    JUST EXIT? Will e xit the menu options without sa ving any changes . If you with to e xit without saving the ne w value then press TEST , if not press MENU . T o access and use the SPECIAL MENU , f ollow steps 1 - 6 under the OPERA T OR MENU e xcept press both the TEST and Choice s witch simultaneously f or three seconds. The f ollowing char t belo ...

メーカー Boca Research カテゴリー Printer

Boca Research Adjustable MC Ghostのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Adjustable MC Ghostの取扱説明書
- Boca Researchの製品カード
- パンフレット
- またはBoca Research Adjustable MC Ghostの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Boca Research Adjustable MC Ghostの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Boca Research Adjustable MC Ghostの取り付け説明書、サービスマニュアル、簡易説明書、またはBoca Research Adjustable MC Ghostのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Boca Research Adjustable MC Ghostの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Boca Research Adjustable MC Ghostデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBoca Research Adjustable MC Ghostを使用するのを助ける技術的文書のことです。説明書は通常、全てのBoca Research Adjustable MC Ghostユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Boca Researchの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Boca Research Adjustable MC Ghostの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBoca Research Adjustable MC Ghostの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Boca Research Adjustable MC Ghostに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Boca Research Adjustable MC Ghostデバイスの基本機能を使うにあたってのヒント。 Boca Research Adjustable MC Ghostのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Boca Research Adjustable MC Ghostに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBoca Research Adjustable MC Ghostのメーカー/サービスへの連絡先に関する情報。

Boca Research Adjustable MC Ghostについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBoca Research Adjustable MC Ghostの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBoca Research Adjustable MC Ghostで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)