  • Sears 390.2518 - page 1

    SEARS OWNER'S MANUAL MODEL NO. 390.2514 390.2518 CAUTION: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. Save This Manual For Future Reference. I:RRFTSMRN ° PROFESSIONAL "HYDROGLASS ''® SHALLOW WELL JET PUMP • Safety Instructions • Installation • Operation • Troubleshootin ...

  • Sears 390.2518 - page 2

    READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety aler'c symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury: DANGER warns about hazards that will cause serious personal injury, death or major property damage ff ignored. WARNING warn ...

  • Sears 390.2518 - page 3

    CONTENTS Safety .............................................................................................. 2 Warranty/Introduction ................................................................... 3 Pump Performance ........................................................................ 3 Major Components .................................... ...

  • Sears 390.2518 - page 4

    MAJOR COMPONENTS / PIPING MAJOR COMPONENTS AND WHAT THEY DO NOTICE: Use Teflon tape supplied with the pump for making all threaded connections to the pump. Impeller and Jet Impeller turns with motor shaft, causing water to fly out from its rim by centrifugal force. Impeller rotation creates a vacuum which pulls in more water. Part of the water is d ...

  • Sears 390.2518 - page 5

    ELECTRICAL Disconnect power before working on pump, motor, pressure switch, or wiring. Motor Switch Settings If the motor can operate at either 115 or 230 volts, it is set at the factory to 230 volts. Do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor. NOTICE: Never wire a 115 volt motor to a 230 ...

  • Sears 390.2518 - page 6

    ELECTRICAL WIRING CONNECTIONS [_.WARNING_ Fire hazard. Incorrect voltage can cause a fire or seriously damage the motor and voids the warranty. The supply voltage must be within ± 10% of the motor nameplate voltage. NOTICE: Dual-voltage motors are factory wired for 230 volts. If nec- essary, reconnect the motor for 115 volts, as shown. Do not alte ...

  • Sears 390.2518 - page 7

    INSTALLATION / OPERATION INSTALLATION SEARS jet pumps should be used with Captive Air* Tanks (See Figure 7). I_IMINGpLU8 PRESSURE $WITGH TO,_ICE BUILT-IN ( VALVE __. 1-114" pLASTIC pIp_ pLASTIC FtPE ADAPTER* PUMPTOTANK SIDE VIEW ;ApTNE AIF_ TANK Figure 7 For mounting pump to tank, purchase tank fittings Kit No. 2788. SEARS Captive Ai_ Tanks ar ...

  • Sears 390.2518 - page 8

    SERVICE MAINTAINING YOUR PUMP Lubrication It is not necessary to lubricate the pump or its motor. The motor bearings are lubricated for life. The mechanical shaft seal in the pump is water lubricated and self-adjusting. Draining for Winter When the pump is to be disconnected from service, or is in dan- ger of freezing, it must be drained. The pump ...

  • Sears 390.2518 - page 9

    SERVICE C. With finger pressure press seat firmly and squarely into cav- ity. See Figure 12A. Polished face of seat faces inside of pump. If seat will not locate properly, place cardboard washer over polished face and use piece of 3/4" standard pipe for press- hag purposes. See Figure 12B. Figure 12B 483 0194 D. Dispose of cardboard washer and ...

  • Sears 390.2518 - page 10

    REPAIR PARTS 29 28 I 1 / 26 2 3 3A 7 8 lO 25 25A 23 766 1194 22 21 19 20 ]0 ...

  • Sears 390.2518 - page 11

    REPAIR PARTS 1/2 HP 3/4 HP Key Model Model Part No. 390,2514 390.2518 Description 1"* 2 3* 3A 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21" 22 23 24 25* 25A* 26 27 28* 29 J218-953C 17351-0009 WC78-41T L176-47P U9-399 U 109-6A J 105-40PE J1-39P U30-542SS C19-54SS U9-201 N32P-66 N34P-19 N76-29P J20-18 N176-28PB U37-673P U111-212T U9-226 ...

  • Sears 390.2518 - page 12

    TROUBLESHOOTING CHART PROBLEM POSSIBLE CAUSES REMEDIES Motor will not run. 1. Disconnect switch is off. 1. Be sure switch is on. 2. Fuse is blown. 2. Replace fuse. 3. Starting switch is defective. 3. Replace starting switch. 4. Wires at motor are loose, 4. Refer to instroctions on wiring. disconnected, or wired incorrectly. Check and tighten all wi ...

  • Sears 390.2518 - page 13

    13 ...

  • Sears 390.2518 - page 14

    14 ...

  • Sears 390.2518 - page 15

    15 ...

  • Sears 390.2518 - page 16

    SEARS OWNER'S MANUAL MODEL NO. 390.2514 390.2518 The model number of your Shallow Well Jet Pump will be found on the pump body. When requesting service or ordering parts, always give the following information: • Product Type • Model Number • Part Number • Part Description CRRFTSMRW PROFESSIONAL "HYDROGLASS ''® SHALLOW W ...

メーカー Sears カテゴリー Water Pump

Sears 390.2518のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 390.2518の取扱説明書
- Searsの製品カード
- パンフレット
- またはSears 390.2518の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sears 390.2518の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sears 390.2518の取り付け説明書、サービスマニュアル、簡易説明書、またはSears 390.2518のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sears 390.2518の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sears 390.2518デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSears 390.2518を使用するのを助ける技術的文書のことです。説明書は通常、全てのSears 390.2518ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Searsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sears 390.2518の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSears 390.2518の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sears 390.2518に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sears 390.2518デバイスの基本機能を使うにあたってのヒント。 Sears 390.2518のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sears 390.2518に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSears 390.2518のメーカー/サービスへの連絡先に関する情報。

Sears 390.2518についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSears 390.2518の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSears 390.2518で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)