Miller Electric DS-74DX12の取扱説明書

52ページ 1.66 mb
ダウンロード

ページに移動 of 52

Summary
  • Miller Electric DS-74DX12 - page 1

    DS-74DX12, and DS-74DX16 OM-1500-14 207 499H 2007 − 07 Processes Description MIG (GMAW) W elding Flux Cored (FCA W ) W elding (Gas-and Self-Shielding) Submerged (SAW) W elding Wire Feeder (Use with CV Power Sources) DS-74DX Swingarc ™ V isit our website at www.MillerWelds.com File: MIG (GMA W) ...

  • Miller Electric DS-74DX12 - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .Mille ...

  • Miller Electric DS-74DX12 - page 3

    T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc W elding Hazards 1 . . . . . . . ...

  • Miller Electric DS-74DX12 - page 4

    T ABLE OF CONTENTS SECTION 9 − ELECTRICAL DIAGRAM 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 10 − P ARTS LIST 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPTIONS AND ACC ...

  • Miller Electric DS-74DX12 - page 5

    OM-1500-14 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury . The possible hazards are shown in the adjoining symbols ...

  • Miller Electric DS-74DX12 - page 6

    OM-1500-14 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases. D If ventilation is poo ...

  • Miller Electric DS-74DX12 - page 7

    OM-1500-14 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit. ...

  • Miller Electric DS-74DX12 - page 8

    OM-1500-14 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.) Battery posts, terminals and related accessories contain lead and l ...

  • Miller Electric DS-74DX12 - page 9

    OM-1500-14 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes. 2-1. S ym bole s ut ilisés DANGER! − Indique une situation dangereuse qui si on l’évite pas peut donner la mort ou des blessures grav ...

  • Miller Electric DS-74DX12 - page 10

    OM-1500-14 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces. DES PIÈCES CH ...

  • Miller Electric DS-74DX12 - page 11

    OM-1500-14 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort. D Fermer l’alimentation du gaz protecteur en cas de non-utilisation. D V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué. LES CHAMPS MAGNETIQUES peuv- ent affecter des implants m ...

  • Miller Electric DS-74DX12 - page 12

    OM-1500-14 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage. DES ORGANES MOBILES peuvent provoquer des blessures. D S’abstenir de toucher d ...

  • Miller Electric DS-74DX12 - page 13

    OM-1500-14 Page 9 2-5. P ri nci pal es n or me s de s écu ri té Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .global.ihs.com). Recommended Safe Practices for the Preparation for W elding and Cut- ting of Containers and Piping , American ...

  • Miller Electric DS-74DX12 - page 14

    OM-1500-14 Page 10 ...

  • Miller Electric DS-74DX12 - page 15

    OM-1500-14 Page 1 1 SECTION 3 − INTRODUCTION 3-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating W eight 24 V olts AC Single-Phase 10 Amperes 50/60 Hertz Constant V oltage (CV) DC With 14-Pin And Contactor Control Standard: 50 T o 780 ipm (1.3 T o 19.8 mpm) Optiona ...

  • Miller Electric DS-74DX12 - page 16

    OM-1500-14 Page 12 4-2. Installing Control Box And Adjusting Tilt 1 W eld Control 2 Bracket 3 Screw Bracket and screws are installed onto bottom of control at factory . 4 Swivel Loosen screws. Place control on swivel and slide forward. Tighten screws. 5 T ilt Bracket 6 Rear Pivot Screw 7 Front Screw Loosen rear pivot screw. Remove front screw . Piv ...

  • Miller Electric DS-74DX12 - page 17

    OM-1500-14 Page 13 4-4. Installing Wire Guide Extension ST-152 383 1 Wire Guide Fitting 2 Bolt 3 Monocoil Liner 4 Wire Guide Extension T ighten bolt to secure liner in wire guide fitting. Do not overtighten bolt and crush liner . Repeat procedure for opposite side. T ools Needed: 1 2 3 4 3/8 in ...

  • Miller Electric DS-74DX12 - page 18

    OM-1500-14 Page 14 803 195 1 W elding Power Source 2 Remote 14 Connection 3 Negative ( − ) W eld Output Cable 4 Positive (+) Weld Output Cable 5 W orkpiece 6 Weld Control 7 Boom 8 Gun 9 Swivel 10 Pipe Post And Base 1 1 Gas Hose 12 Gas Supply and Regulator (Customer Supplied) . Shielding gas pressure not to exceed 100 PSI (689 kPa). 4-5. Equipment ...

  • Miller Electric DS-74DX12 - page 19

    OM-1500-14 Page 15 803 197-A 1 Interconnecting Cables 2 Interconnecting Cable Receptacles 3 14-Pin Cord 4-6. Control Box Connections 1 3 2 4-7. 14-Pin Plug Information Pin* Pin Information A 24 volts ac with respect to socket G. A J K B Contact closure to A completes 24 volts ac contactor control circuit. A J B K I L G Circuit common for 24 volts A ...

  • Miller Electric DS-74DX12 - page 20

    OM-1500-14 Page 16 4-8. Removing Safety Collar And Adjusting Boom ST-142 599-C 1 Locking Knob T ighten knob to prevent boom movement. Loosen knob to allow boom movement. Change knob po- sition to limit upward movement. Pull boom down slightly and re- move safety collar . Boom should balance in any position from hori- zontal to 60 degrees above hori ...

  • Miller Electric DS-74DX12 - page 21

    OM-1500-14 Page 17 4-1 1. Installing And Threading Welding Wire T ools Needed: 3/16, 5/64 in 3/8, 15/16 in Install wire spool. Ad- just tension nut so wire is taut when wire feed stops. Install wire guide. Pressure Indicator Scale Pressure Adjust Install drive rolls. NONCONDUCTIVE SURF ACE NONCONDUCTIVE SURF ACE No Wire Slip Wire Slips Drive Rolls ...

  • Miller Electric DS-74DX12 - page 22

    OM-1500-14 Page 18 4-12. Setting Internal DIP Switches 1 DIP Switch S1 2 DIP Switch S4 (Not For Customer Use) D IP switch S1 allows the user to make a num- ber of choices af fecting unit operation. w Defining Motor Speed (S1-7 & 8) Switches 7 and 8 allow the user to define whether the motor in use is standard speed (50-780 inches per minute), o ...

  • Miller Electric DS-74DX12 - page 23

    OM-1500-14 Page 19 4-13. Power Source Selection Menu . When the feeder is turned on, the Power Source Selection Menu allows the operator to se- lect a default power source. Selecting a default power source, automatically sets the correct Vmin and Vmax set- tings for adjusting the output voltage of the power source. First Time Feeder Is T urned On T ...

  • Miller Electric DS-74DX12 - page 24

    OM-1500-14 Page 20 SECTION 5 − OPERA TION 5-1. Operational T erms The following is a list of terms and their definitions as they apply to this wire feeder: General T erms: Cold Wire Jog Feeding wire without contactor or gas valve being energized. Sequence A portion of the weld program, such as preflow , run-in, start, weld, crater , burnback, and ...

  • Miller Electric DS-74DX12 - page 25

    OM-1500-14 Page 21 5-4. Jog/Purge Switch 1 803 194 2 1 Jog/Purge Switch 2 Adjust Control Pressing the J og/Purge switch allows the op- erator to jog wire without energizing the weld power or gas valve circuit. • The unit provides the ability to jog the wire feeder by means of the gun trigger or the Jog/Purge switch. If the welding arc does no t i ...

  • Miller Electric DS-74DX12 - page 26

    OM-1500-14 Page 22 5-6. Program Push Button 1 3 Program 2 1 Program Display The number of the active program is displayed. 2 Program Push Button Press button to activate program select feature. T o change the pro- gram number , press the Program push button and rotate the Adjust control. 3 Program Push Button LED The LED lights to indicate the Pro- ...

  • Miller Electric DS-74DX12 - page 27

    OM-1500-14 Page 23 5-8. Lower Display 2 Wire Speed Amps 1 5 4 3 1 Lower Display The lower display shows wire speed or amperage. The unit displays and adjusts only preset wire speed at idle. When the unit is in a welding state, actual wire speed is displayed for the active welding sequence. 2 Lower Display Push Button Press button to choose between ...

  • Miller Electric DS-74DX12 - page 28

    OM-1500-14 Page 24 5-10. Adjust Control Adjust 1 1 Adjust Control The Adjust control is used to change various sequence parame- ters, and to select various se- quences. Refer to the section for th e function in question for informa- tion related to using the Adjust con- trol. Start Crater Pre/Postflow Sequence 5-1 1. Sequence Push Button 1 3 2 W el ...

  • Miller Electric DS-74DX12 - page 29

    OM-1500-14 Page 25 5-12. Auxiliary Menus Program Start Crater Pre/Postflow T rigger Hold Adjust V olts Time (sec) Wire Speed Amps Sequence Setup Dual Schedule 3 4 2 9 8 1 5 7 6 1 Program Display 2 Program Push Button 3 Sequence Push Button 4 Upper Display 5 Upper Display Push Button 6 Lower Display 7 Lower Display Push Button 8 Adjust Control 9 Set ...

  • Miller Electric DS-74DX12 - page 30

    OM-1500-14 Page 26 Burnback • If the Setup push button is pressed, the unit allows burnback time to be set. Burnback time and voltage can be specified when the lower display indicates “BURN” an d the upper display indicates the burnback time or voltage. The Adjust control is used to set the desired burnback time or voltage. Burnback settings, ...

  • Miller Electric DS-74DX12 - page 31

    OM-1500-14 Page 27 SECTION 6 − SETTING SEQUENCE P ARAMETERS 6-1. Sequence Parameters In A Program . For more information on Sequence Push Button see Section 5-1 1. If time is set to zero in W eld sequence, welding continues until gun trigger is released. If time is set to zero in any timed sequence except Weld, the sequence is skipped. T rigger P ...

  • Miller Electric DS-74DX12 - page 32

    OM-1500-14 Page 28 SECTION 7 − SETTING DUAL SCHEDULE P ARAMETERS 7-1. Optional Dual Schedule Switch Diagrams 1 Maint 2P (Maintained-Contact 2-Pole Switch) 2 Maint 1P (Maintained-Contact 1-Pole Switch) . Will not function with trigger hold and dual schedule. A DSS-9 is recommended for this application. 1 2 3 4 B A TR 2 11 22 3 A 4 B DSS-8 DSS-9 1 ...

  • Miller Electric DS-74DX12 - page 33

    OM-1500-14 Page 29 7-2. Diagnostics 803 063-A 1 LED3 On Right Side Motor Control Board PC1 2 LED3 On Left Side Motor Control Board PC101 3 LED4 On Dual Board PC70 . There is a two-position DIP switch S1 located on motor con- trol boards PC1 and PC101. These switches are factory-set in the off position and must re- main in that position for the unit ...

  • Miller Electric DS-74DX12 - page 34

    OM-1500-14 Page 30 7-3. Diagnostics For User Defined Options 2 803 198 1 1 Front Panel 2 Front Panel Board PC20 User Defined Shutdown Error Messages (Additional hardware required for these to be functional) If OPT1 and/or OPT2 are enabled without additional hardware setup, the following error messages will be displayed on the front panel meters. OP ...

  • Miller Electric DS-74DX12 - page 35

    OM-1500-14 Page 31 8-2. T roubleshooting ! Disconnect power before troubleshooting. T rouble Remedy Wire feeds, shielding gas flows, but elec- trode wire is not energized. Check interconnecting cord connections. If secure, check cord for continuity and repair or replace (see Sections 4-5 and 4-6). Wire feeder is on, meter(s) do not light up, motor ...

  • Miller Electric DS-74DX12 - page 36

    OM-1500-14 Page 32 SECTION 9 − ELECTRICAL DIAGRAM Figure 9-1. Circuit Diagram ...

  • Miller Electric DS-74DX12 - page 37

    OM-1500-14 Page 33 204 144-C ...

  • Miller Electric DS-74DX12 - page 38

    OM-1500-14 Page 34 SECTION 10 − P ARTS LIST 803 189-C 1 2 3 4 5 6 10 12 13 14 16 17 18 19 20 21 26 22 28 2 Fig 10-4 Fig 10-2 Fig 10-3 Fig 10-5 7 27 8 9 11 23 24 25 29 30 Fig 10-4 . Hardware is common and not available unless listed. 15 15 14 2 31 31 Figure 10-1. Main Assembly ...

  • Miller Electric DS-74DX12 - page 39

    OM-1500-14 Page 35 Quantity Description Part No. Dia. Mkgs. Item No. Model DS-12 DS-16 Figure 10-1. Main Assembly 1 See Note Control Box, (Fig 10-2) 1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 201 319 Cable, Interconnecting (consisting of) 2 0 . . . . . . . . . . . . . . ...

  • Miller Electric DS-74DX12 - page 40

    OM-1500-14 Page 36 10 9 7 8 9 17 18 19 8 6 5 23 21 25 24 22 1 4 3 2 20 803 200 . Hardware is common and not available unless listed. 16 12 13 14 15 11 Figure 10-2. Control Box Description Part No. Dia. Mkgs. Item No. Figure 10-2. Control Box (Figure 10-1 Item 1) Quantity 1 204 722 Wrapper , Feeder 1 . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric DS-74DX12 - page 41

    OM-1500-14 Page 37 Description Part No. Dia. Mkgs. Item No. Figure 10-2. Control Box (Continued) Quantity 18 134 201 Stand-Off Support, PC Card .312/.375w/Post&lock .43 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 204 721 Enclosure, Control 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric DS-74DX12 - page 42

    OM-1500-14 Page 38 ST-142 306-H 1 23 5 6 7 8 9 10 12 13 14 15 16 17 18 20 21 22 23 29 30 15 14 24 25 26 19 27 28 4 . Hardware is common and not available unless listed. 11 Figure 10-3. Boom Assembly ...

  • Miller Electric DS-74DX12 - page 43

    OM-1500-14 Page 39 Quantity Description Part No. Item No. Model DS-12 DS-16 Figure 10-3. Boom Assembly (Figure 10-1 Item 13) 1 010 313 Pin, Cotter Hair .072 X 1.437 4 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 010 910 Washer , Flat Stl Sae .375 6 6 . . . . . . . . . . . . . . . . . ...

  • Miller Electric DS-74DX12 - page 44

    OM-1500-14 Page 40 See T able 10-1 For Drive Roll & Wire Guide Kits . Hardware is common and not available unless listed. 802 977-B 1 32 33 34 36 35 30 28 29 31 37 27 40 39 38 6 5 3 2 4 7 9 8 11 10 24 25 20 12 15 18 16 22 14 17 19 21 23 22 14 13 26 Figure 10-4. Drive Assembly , Wire Quantity Description Part No. Item No. Model DS-12 DS-16 Figur ...

  • Miller Electric DS-74DX12 - page 45

    OM-1500-14 Page 41 Quantity Description Part No. Item No. Model DS-12 DS-16 Figure 10-4. Drive Assembly , Wire (continued) Dia. Mkgs. 184 136 Kit, Brush Holder 1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 155 098 Kit, Cover Motor Gearbox (consisting of ...

  • Miller Electric DS-74DX12 - page 46

    OM-1500-14 Page 42 8 7 6 9 1 2 3 4 5 6 7 13 12 11 10 ST-081 760-C . Hardware is common and not available unless listed. Figure 10-5. Support, Hub & Reel Description Part No. Item No. Quantity Figure 10-5. Support, Hub and Reel (Figure 10-1 Item 10) 1 058 427 Ring, Retaining Spool 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric DS-74DX12 - page 47

    OM-1500-14 Page 43 T able 10-1. Drive Roll and Wire Guide Kits .023-.025 in. 0.6 mm 151 024 087 130 .030 in. 0.8 mm 151 025 053 695 .035 in. 0.9 mm 151 026 053 700 151 036 072 000 151 052 132 958 .045 in. 1.1/1.2 mm 151 027 053 697 151 037 053 701 151 053 132 957 151 070 083 489 .052 in. 1.3/1.4 mm 151 028 053 698 151 038 053 702 151 054 132 956 15 ...

  • Miller Electric DS-74DX12 - page 48

    ...

  • Miller Electric DS-74DX12 - page 49

    Notes Over 80,000 trained since 1930! 400 T rade Square East, T roy , Ohio 45373 1-800-332-9448 www.weldin g .or g Star t Y our Pr ofessional W eldin g Career Now! ...

  • Miller Electric DS-74DX12 - page 50

    ...

  • Miller Electric DS-74DX12 - page 51

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expe ...

  • Miller Electric DS-74DX12 - page 52

    PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool W orks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarters − US A USA Phone: 920-735-4505 Aut o-At tended USA & Canada F AX: 920-735-4134 Int ernati onal F A X: 920-735-4125 European Headqua rters − U ...

メーカー Miller Electric カテゴリー Welder

Miller Electric DS-74DX12のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DS-74DX12の取扱説明書
- Miller Electricの製品カード
- パンフレット
- またはMiller Electric DS-74DX12の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miller Electric DS-74DX12の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miller Electric DS-74DX12の取り付け説明書、サービスマニュアル、簡易説明書、またはMiller Electric DS-74DX12のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miller Electric DS-74DX12の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Miller Electric DS-74DX12デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiller Electric DS-74DX12を使用するのを助ける技術的文書のことです。説明書は通常、全てのMiller Electric DS-74DX12ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Miller Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miller Electric DS-74DX12の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiller Electric DS-74DX12の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miller Electric DS-74DX12に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miller Electric DS-74DX12デバイスの基本機能を使うにあたってのヒント。 Miller Electric DS-74DX12のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miller Electric DS-74DX12に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiller Electric DS-74DX12のメーカー/サービスへの連絡先に関する情報。

Miller Electric DS-74DX12についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiller Electric DS-74DX12の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiller Electric DS-74DX12で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)