Bosch Appliances 250SX LPの取扱説明書

36ページ 2.61 mb
ダウンロード

ページに移動 of 36

Summary
  • Bosch Appliances 250SX LP - page 1

    MOD EL 2 50S X N G a nd 2 50SX L P T emperature Modulat ed wit h Elect ronic Ignition Suit able for heating pot able wat er only Not approved for space heat ing purpose s (Intende d for varia ble flow applicatio ns with multipl e tapping poin ts) 250 SX NG 250 SX LP 6 720 607 057 US (04.10) A L Warning : I f t h e i n f o r m a t i o n i n t h i s ...

  • Bosch Appliances 250SX LP - page 2

    6 720 607 057 2 Index Index 1W a r n i n g 2 2 Appliance details 4 2.1 Features 4 2.2 250 SX Specif ications (Tech nical data ) 4 2.3 Dimensions an d Minimum installation clearances 6 2.4 Genera l rules to follow for safe op eration 7 2.5 Proper location for installing your heater 7 2.6 Cle arances 8 2.7 Mounting installation 8 2.8 Combustion air r ...

  • Bosch Appliances 250SX LP - page 3

    6 720 607 057 Warning 3 What t o do i f you s mell gas • Clos e gas val ve. Open windows. • Do not tr y to light any ap pliance. • Do n ot touch any e lectrical s witch; do not us e any phone in your bu ilding . • I mm ed ia te ly c al l y ou r g as su pp l ie r f ro m a ne ig hb o r’ s phone. F ollow th e gas su pplier’s in structions ...

  • Bosch Appliances 250SX LP - page 4

    6 720 607 057 4 Applia nce deta ils 2 Applianc e details 2.1 Featur es Parts • Tou ch Pad i nterfa ce contro l • High power pre-mix compact burner with low Nox emissions • Modulating Gas Valve with constant gas:a ir ratio contr ol • Modulating water valve for improved c omfort and tempe rature contro l. Safet y • Flame sensor (ioniza tion ...

  • Bosch Appliances 250SX LP - page 5

    6 720 607 057 App lianc e de tails 5 • Minim um recomme nded wate r pressure : 30 PSI (2.07 bar) • Connecti ons: – Bottom of heater Comb ust ion •N O x ≤ 55 ppm •C O ≤ 250 ppm •C O 2 level set from fa ctory, see ch apter 9.1. Dimens ions • Dep th (in): 8 ½” (2 20 mm) • Width (in): 15 ¾” (400 mm) • Heigh t (in ): 23 ½” ...

  • Bosch Appliances 250SX LP - page 6

    6 720 607 057 6 Applia nce deta ils 2.3 Dimension s and Minimum in stallation clear ances Fig. 5 Dimension s 1 Cover 2 On/Off switch 3 Rese t butto n 4 LCD di splay 5 Program bu tton 6 Temperature buttons Fig. 6 M inimum clearances Model 250 SX TOP (A) 12” FRONT (B) 4” BACK 0” SIDES 4” FLOOR (C ) 12” VENT DIAMETER 3” Table 1 M inimum cl ...

  • Bosch Appliances 250SX LP - page 7

    6 720 607 057 App lianc e de tails 7 2 . 4 G e n e r a l r u l e s t o f o l l o w f o r s a f e operatio n B 1. You should follow these instr uctions when you instal l your hea ter. In the Un ited States: The i n s t a l l a t i o n m u s t c o n f o r m w i t h l o c a l co d e s o r , i n th e absence of local codes, the National Fuel Gas Code A ...

  • Bosch Appliances 250SX LP - page 8

    6 720 607 057 8 Applia nce deta ils 2.6 Cleara nces The 250 S X is design certified for i nstallation on a combus tible w all (see 2 .7 M ounting ins tallation) provid ed the floor cover ing bel ow the heate r is noncom bustible. For installat ions in an alcove or closet, mainta in the minimum c learances to combustible a nd non-c ombustible materi ...

  • Bosch Appliances 250SX LP - page 9

    6 720 607 057 App lianc e de tails 9 – b) In unconfi ned spaces in bu ildings o f convent ional frame, mas onry, or metal const ructio n, infilt rati on air is normal ly adequate to provide air for combustion. • App liances located in confi ned spac es: The confi ned sp ace m ust be pro vided with tw o permanent ope nings, one commen cing withi ...

  • Bosch Appliances 250SX LP - page 10

    6 720 607 057 10 Applia nce deta ils The maximum flue gas exhaust temperature on the 250 SX is 437°F (225° C) Venting Optio ns Exhaust vent diameter and material * Exhaust ven t max imum length * Ex haust vent minimum length Comb ust ion air pipe diameter and ma terial Combustion air pipe maxi mum length Vent pipe clearances with in an unenclosed ...

  • Bosch Appliances 250SX LP - page 11

    6 720 607 057 App lianc e de tails 11 The applia nce s hould be locat ed as close to the poi nt of terminati on as possibl e. The maxi mum v ent length is 26 feet ( 8 m) with one 90 degr ee elbow. Subtra ct 2 ½ feet from the total vent length for each additiona l 90° elbow used (a maxi mum o f th ree 9 0° el bows are permit ted in the to tal ven ...

  • Bosch Appliances 250SX LP - page 12

    6 720 607 057 12 Applia nce deta ils Room s ealed installa tion (TWIN PIPE SYSTEM) Fig. 12 Combus tion air pip e: ≤ 26 ft (8 m ) Exha ust ve nt pipe : ≤ 26 f t (8 m ) I f t h e t o t a l h o r iz o n t a l e x h a u s t v e n t l e n g t h i n a s i d e w a l l installa tion is gr eater than o r equal to 5 f eet (1.5 m), a condens ate drain tub ...

  • Bosch Appliances 250SX LP - page 13

    6 720 607 057 App lianc e de tails 13 Recomm ended exh aust vent t erminator pos ition Fig. 16 * Subject to local c odes and anticipated sn ow level ** Other equipment t hat operate s with a me chanical ai r inlet may require grea ter dista nces, refere nce manufact urer's instruc tio ns Ref. Description Minimum distance A Directly below an op ...

  • Bosch Appliances 250SX LP - page 14

    6 720 607 057 14 Applia nce deta ils Supportin g the exha ust vent sys tem and th e use of an external condensate trap Extern al cond ensate tr aps B A condensat e trap must be used in any sidewall exha ust vent in stallatio ns when the tota l vent len gth is ≥ 5 ft (1.5 m) OR the vent pipe pa sses thr ough an u n h e a t e d s p a c e ( b e l o ...

  • Bosch Appliances 250SX LP - page 15

    6 720 607 057 App lianc e de tails 15 A co ndensate drai n tu be must be attach ed to t he exhau st collar of t he heater for any vertica lly e xhaust ed vents, see p age 14. Fig. 20 Vertical venting inst allation - Masonry Chimney (combusti on air piping not being shown) A co ndensate drai n tu be must be attach ed to t he exhau st collar of t he ...

  • Bosch Appliances 250SX LP - page 16

    6 720 607 057 16 Applia nce deta ils FOR NA TU RAL GAS Maximu m Capacity of pipe i n Cubic Feet of Gas per Hour for Gas Pres sure of 0.5 Psig or less and a Pressure dr op of 0. 3 in Water Col umn (0 .75mbar ).(Bas ed on a 0 .60 Speci fic Grav ity G as) Btu number s given i n thou sands. Fig. 22 Follow boxed number s for pipin g just one 250 SX (exa ...

  • Bosch Appliances 250SX LP - page 17

    6 720 607 057 App lianc e de tails 17 2.11 Gas line sizing B It is strongl y recomme nded that the Natu ral Gas pipe be B lack Iron pipe th e entire dista nce from the outside met er to the inlet of th e gas connecti on. ¾” B l a c k I r o n p i p e u p t o 2 0 f e e t ( 6 . 1 m ) a n d 1 ” B l a c k I r o n pipe up to 70 feet (21.34m) distanc ...

  • Bosch Appliances 250SX LP - page 18

    6 720 607 057 18 Applia nce deta ils 2.13 Water con nections W h e n f a c i n g t h e h e a t e r , t h e ¾ ” c o l d w a t e r i n l e t i s o n t h e b o t to m r ig h t a n d th e h o t wa t e r o u t l e t i s o n t h e b o t t o m left . Instal l the heater centra lly in the build ing if possibl e and ma ke hot wa ter p iping ru ns as sh o ...

  • Bosch Appliances 250SX LP - page 19

    6 720 607 057 App lianc e de tails 19 2.14 Ele ctrical connections The 250 SX requires an ele ctrical p ower su pply from a 120VAC 60Hz ci rcuit and mu st be p roperly grounde d. A means f or switch ing of f the 120VAC power supply must be provided. The heate r is wired as shown in the wiring diag ram (chapter 6, Fi g. 36). 2.15 Operat ing instruct ...

  • Bosch Appliances 250SX LP - page 20

    6 720 607 057 20 Applia nce deta ils When the heater is i n operat ion you will hear its power vent fan a nd burne r operatin g. Upo n turning off the h ot water flow the power v ent fan w ill cont inue to op erate for up to 60 seconds to exha ust all flue ga ses. Th e power vents fan s peed is va riable dep ending on the rat e of ho t water used a ...

  • Bosch Appliances 250SX LP - page 21

    6 720 607 057 Operat ion instructi ons 21 3 Operation in structions Fig. 26 1 On/O ff switch 2 Reset butt on 3 Progr am Key 4 Increasing temperat ure selecto r 5 Decreasing temperat ure selecto r 6 LCD displ ay 3.1 Power On B T o sta rt the a ppliance switch the bu tton to pos ition ( I ). LCD displa y the default t emperature - t emperature facto ...

  • Bosch Appliances 250SX LP - page 22

    6 720 607 057 22 Operat ion in stru ctions Setti ng th e wat er tem perat ure The desired t emperat ure o f the hot wat er can be adju sted on the front control panel of the heate r. The 250 SX has an el ectronically controlle d gas valv e that modu lates the burne r input in r esponse to b oth varying hot wat er flo w rates and/or cha nges in a ny ...

  • Bosch Appliances 250SX LP - page 23

    6 720 607 057 Operat ion instructi ons 23 3.3 Use of remote contro l accessory Fig. 30 R emote control The wireless remot e cont rol a ccessory and the tempera ture sel ector b uttons o n th e front o f the wa ter heate r operate i dentica lly. Cont act your distri butor or CEC to o rder if the remote control acces sory is prefer red. Mo dification ...

  • Bosch Appliances 250SX LP - page 24

    6 720 607 057 24 Maint enance a nd se rvice 4 Maintenance and service The unit shoul d be checked o nce a year by a gas technic ian. If re pairs are needed, the repairs sho uld be done b y a gas technicia n To r emove front cov er B R e m o v e p l a s t i c d e c a l s o n f r o n t p a n e l ( P a g e 5 , F i g . 4). B Lo os en th e t wo Ph il ip ...

  • Bosch Appliances 250SX LP - page 25

    6 720 607 057 Troubleshooting 25 Test by following 4th bullet under BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNED O N. LOW WATER FLOW/PRESSURE • T o o m a n y h o t w a t e r a p p l i c a t i o n s a r e b e i n g us ed si mul ta ne ous ly or too mu ch flo w i s b ei ng demande d The 250 SX will effect ively sup port two 2.0 -2.5 gpm shower hea ...

  • Bosch Appliances 250SX LP - page 26

    6 720 607 057 26 Troubleshooting Display Cause Solution E9 Temperature limiter opened circuit (overheat). Trips at 220F ( 104C). Check connections.* Check heat exchanger condition.* EA No i onization during safety t ime (safety time out) . Note: appliance makes 3 ignition attempts before entering error mode “EA”. Check gas pressure.* Check that ...

  • Bosch Appliances 250SX LP - page 27

    6 720 607 057 Electr ical di agram 27 6 Electrical d iagram Fig. 36 Electrical scheme 1 Intlet water temp erature sensor 2 Ioniz ation s ensor 3 Water flow sensor 4 Over heat protect ion 5 Temperature limiter 6 Gas v alv e 7 Fan 8 Water valve 9 AC Plug 10 Ignit ion ele ctrode 11 Dis pla y P CB 12 ON/OFF switch 13 Fuse T 2,5A 14 Fuse T 3,15A 15 Ter ...

  • Bosch Appliances 250SX LP - page 28

    6 720 607 057 28 250 SX Functiona l scheme 7 250 SX Functional s cheme Fig. 37 Func tional scheme ...

  • Bosch Appliances 250SX LP - page 29

    6 720 607 057 Inte rior comp onent s dia gram a nd par ts li st 29 8 Interior components diagram and parts list 8.1 Interi or componen ts Fig. 38 C omponents 1 Cover 2 On/O ff switch 3 Reset butt on 4 LCD displ ay 5 Program b u tton 6 Temperature sw itches 7 Flue gas c ollector 8 Mi xer 9 Heat exchang er 10 Obs er vat ion win dow 11 Inle t air duc ...

  • Bosch Appliances 250SX LP - page 30

    6 720 607 057 30 Inte rior com ponent s diagr am an d parts lis t 8.2 Comp onents diagram Fig. 40 Comp onents Diagram ...

  • Bosch Appliances 250SX LP - page 31

    6 720 607 057 Inte rior comp onent s dia gram a nd par ts li st 31 8.3 Parts list Item Descri ption Ref erence 1 Front cover 8 705 42 1 83 7 2 Shield 8 7 05 506 66 1 3 Heat exc hanger 8 7 05 406 285 4 Heat exc hanger top gasket 8 7 04 7 0 1 052 5 Clip 8 7 1 6 1 02 607 6 Heat exc hanger bottom ga sket 8 7 04 7 0 1 054 7 O-ring 8 700 205 1 4 7 8 Temp ...

  • Bosch Appliances 250SX LP - page 32

    6 720 607 057 32 Specia l adjustm ent for mea suring and adjusting CO2 level s 9 Special adj ustment for measuring and adjus ting CO 2 levels The CO 2 can only be adjusted by a certi fied gas techni cian wit h a cali brated CO 2 ana lyzer. 9.1 Adjust ing the unit Fact ory settings of this applian ce are listed in table 7. Further ad justment is onl ...

  • Bosch Appliances 250SX LP - page 33

    6 720 607 057 Specia l adjustmen t for measuring and ad justing CO2 lev els 33 Fig. 43 Adjusting Leave “Pr ogram” mode B Turn ON/OFF switch in positi on OFF and then ON again . i NOTE: turn ing screw clockwise decreases CO 2 lev el, tur ning coun tercl ockwis e inc reases it. Caution: Faulty ignition or noisy operation ma y occur if CO 2 levels ...

  • Bosch Appliances 250SX LP - page 34

    6 720 607 057 34 Protect ing the environme nt 10 Protect ing the envir onment Packin g Th e pa ck ing b ox may be ful ly rec yc le d as co nfi rme d by the rec ycling symbol . Component s Many parts in the heater can be full y recycle d in the end o f t h e p r o d u c t l i f e . C o n t a c t y o u r c i t y a u t h o r i t i e s f o r inform ati ...

  • Bosch Appliances 250SX LP - page 35

    6 720 607 057 Twel ve Year L imited Wa rranty 35 11 Twelve Year Limited Warranty Gene ral Aquasta r wate r heaters are warra nted by the Manufa cturer (BOSCH) through Cont rolle d Energy Corp. Contro lled Energy Corp. (CEC) will furnish a repla cement heat exchan ger and will furn ish a repla cement of any other par t which fa ils in nor mal use an ...

  • Bosch Appliances 250SX LP - page 36

    Replacemen t Parts available from North American Distributo r CONT RO L LED E NE RG Y CORP . 340 Mad Ri ver Park W aitsf ield, V er mont 0567 3 Phone 800-642- 3 1 1 1 Fax (802) 496-6924 www .cont rolledenergy.com/tech tec hsupport@controll edenergy .com VU L C ANO T ermodoméstic os S.A. Estra da de Cacia 380 1 - 856 Av eiro - PORTUGAL Recyc led pa ...

メーカー Bosch Appliances カテゴリー Water Heater

Bosch Appliances 250SX LPのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 250SX LPの取扱説明書
- Bosch Appliancesの製品カード
- パンフレット
- またはBosch Appliances 250SX LPの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bosch Appliances 250SX LPの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bosch Appliances 250SX LPの取り付け説明書、サービスマニュアル、簡易説明書、またはBosch Appliances 250SX LPのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bosch Appliances 250SX LPの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bosch Appliances 250SX LPデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBosch Appliances 250SX LPを使用するのを助ける技術的文書のことです。説明書は通常、全てのBosch Appliances 250SX LPユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bosch Appliancesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bosch Appliances 250SX LPの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBosch Appliances 250SX LPの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bosch Appliances 250SX LPに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bosch Appliances 250SX LPデバイスの基本機能を使うにあたってのヒント。 Bosch Appliances 250SX LPのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bosch Appliances 250SX LPに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBosch Appliances 250SX LPのメーカー/サービスへの連絡先に関する情報。

Bosch Appliances 250SX LPについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBosch Appliances 250SX LPの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBosch Appliances 250SX LPで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)