Graco Inc. 207-860の取扱説明書

16ページ 0.36 mb
ダウンロード

ページに移動 of 16

Summary
  • Graco Inc. 207-860 - page 1

    306–993 Rev . D Supersedes Rev . B and PCN C First choice when quality counts.  INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Hydra-Clean ) Pressure W ashers 42 bar , 4.2 MPa (600 psi) Maximum Working Pressure For Mounting on Open 55 Gallon Supply Drum (Can be wall m ...

  • Graco Inc. 207-860 - page 2

      T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T roubleshooting 10 . . . . . . . . . . . ...

  • Graco Inc. 207-860 - page 3

      W ARNING INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury , including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury .  Fluid injected into the skin might look like just a cut ...

  • Graco Inc. 207-860 - page 4

    4 306-993 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re - sult in a fire or explosion and serious injury .  Ground the equipment and the object being sprayed. Refer to Grounding on page 5.  If there is any static sparking or you feel an electric shock whil ...

  • Graco Inc. 207-860 - page 5

    5 306-993 Setup Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE OR EXPLOSION HAZARD on page 4. Although water generally provides a natural electrical ground, the following equipment must be grounded if the cleaning chemical are volatile. 1. When cleaning in en ...

  • Graco Inc. 207-860 - page 6

      Setup Connect Hoses and Mount Pump Connect hoses and pump as follows: NOTE: This pump is supplied with a bracket (D) which holds it to the side of a drum. If you want to install the pump on a wall, do not install the hanging bracket. Use Graco W all Mounting Bracket 206–778 or equivalent for wall setup. 1. Screw the hose ...

  • Graco Inc. 207-860 - page 7

    7 306-993 Setup  D U B F M J R P KEY A Barbed Hose Stud B Suction Hose C Pump Intake housing D Bracket E Screw , Lockwasher , and Nut F Pump Runaway V alve G Air Line Lubricator H Pump Air Bleed V alve (required, for pump) J Air Regulator and Gauge K Air Line Filter L Air Line Drain V alve M Bleed–type Air V alve (for accessorie ...

  • Graco Inc. 207-860 - page 8

    8 306-993 Operation General Information The following instructions are for operation of the Monark 5:1 Ratio Hydra–Clean Pressure W ashers Model 205–985 and Model 207–860. Callouts in parentheses refer to Figure 2. Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in - jected through the skin and cause serio ...

  • Graco Inc. 207-860 - page 9

      Operation W ARNING T o avoid serious injury , including fluid injection and splashing in the eyes or on the skin, never point the gun at yourself or anyone else. Before Using See Fig. 2. Prepare cleaning solution as instructed, observing all safety precautions. Pre-mix powered cleaners in a separate bucket of hot water bef ...

  • Graco Inc. 207-860 - page 10

    10 306-993 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to relieve the pressure . Note: Check all possible problems and solutions before disassembling. Problem Cause Solution Exc ...

  • Graco Inc. 207-860 - page 11

    11 306-993 Service General W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. See Parts illustration for referenced items. Shut of f the air supply to the pump and relieve the pressure . Check the air line lubricator often and keep it filled with oil ...

  • Graco Inc. 207-860 - page 12

    12 306-993 Parts 0676 8 17 (MODEL 205–985) 11 4 13 2 18 15 21 19 14 16 20 3 5 12 6 Model 205–985 Monark Hydra-Clean and Model 207–860 Monark Hydra-Clean 1 7 8 8 9 10 (MODEL 207–860) 22 23 ...

  • Graco Inc. 207-860 - page 13

    13 306-993 Parts Model 207–860 Monark Hydra-Clean Ref No. Part No. Description Qty . 1 214–847 AIR LINE LUBRICA TOR 1 2* 206–300 FIL TER, fluid intake 1 3 224–343 5:1 Ratio Monark Pump See manual 308–1 16 for parts 1 4 102–022 BUSHING, hex; 1/2 npt; 1/4 npt thd size 1 5 102–023 SCREW , hex cap; 1/4–20 thd size; 3/4” (19mm) long 1 ...

  • Graco Inc. 207-860 - page 14

    14 306-993 Accessories Stainless Steel Spray Tips AIR SUPPL Y T O PUMP TIP NO. ORIFICE SIZE SPRA Y ANGLE 70 PSI (4.8 bar , 0.48 MPa) 100 psi (7 bar , 0.7 MPa) NO . SIZE ANGLE GPM CFM WP GPM CFM WP 164–435 .043 40 160–964 .043 25 164–434 .052 25 164–436 .052 40 1.6 17 610 1.8 24 840 164–438 .052 65 160–963 .062 25 2.3 23 560 2.6 32 750 K ...

  • Graco Inc. 207-860 - page 15

    15 306-993 Dimensions 24.5” (622 mm) 1 1.75” (298 mm)  T echnical Data Air pressure range 40 to 120 psi (2.8 to 8.4 bar , .28 to .84 MPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air volume requirements 8.2 cfm (0.23 m 3 /min.) at 100 psi (7 bar , 0.7 MPa), . . . . . . . . . . . ...

  • Graco Inc. 207-860 - page 16

    16 306-993 Graco Standard W arranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warrant ...

メーカー Graco Inc. カテゴリー Pressure Washer

Graco Inc. 207-860のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 207-860の取扱説明書
- Graco Inc.の製品カード
- パンフレット
- またはGraco Inc. 207-860の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco Inc. 207-860の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco Inc. 207-860の取り付け説明書、サービスマニュアル、簡易説明書、またはGraco Inc. 207-860のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco Inc. 207-860の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco Inc. 207-860デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco Inc. 207-860を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco Inc. 207-860ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Graco Inc.の取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco Inc. 207-860の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco Inc. 207-860の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco Inc. 207-860に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco Inc. 207-860デバイスの基本機能を使うにあたってのヒント。 Graco Inc. 207-860のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco Inc. 207-860に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco Inc. 207-860のメーカー/サービスへの連絡先に関する情報。

Graco Inc. 207-860についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco Inc. 207-860の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco Inc. 207-860で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)