  • Regency P121RC - page 1

    FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. FPI FIREPLACE PRODUC ...

  • Regency P121RC - page 2

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P121/ P121LC/P121RC/P131 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a swi ...

  • Regency P121RC - page 3

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 3 T ABLE OF CONTENTS Operating Instructions Operating Instructions ............................................... 2 9 Lighting Procedure .................................................... 2 9 Shutdown Procedure ................................................. 2 9 F ...

  • Regency P121RC - page 4

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 4 This is a copy of the label that accompanies each P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the ...

  • Regency P121RC - page 5

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 5 INST ALLA TION CHECKLIST 1 ) Locate appliance a ) Room location, page 8. b) Clearances to Combustibles, page 9. c ) Mantle Clearances, page 9. d ) Framing & Finishing Requirements, page 10. e ) Venting Requirements, pages 11-19. 2 ) Assemble Top Standoffs, page ( ...

  • Regency P121RC - page 6

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 6 INST ALLA TION SPECIFICA TIONS P121-1 See Thru P131-1 Pier Note: These units are non-load bearing. ...

  • Regency P121RC - page 7

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 7 P121LC-1 Left Corner Unit P121RC-1 Right Corner Unit INST ALLA TION Note: These units are non-load bearing. ...

  • Regency P121RC - page 8

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 8 LOCA TING YOUR GAS FIREPLACE 1 ) When selecting a location for your stove, ensure that the clearances are met as outlined on page 9. 2 ) Provide adequate clearances for servic- ing. 3 ) The appliance must be installed on a flat, solid, continuous surface (e.g. wood, ...

  • Regency P121RC - page 9

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 9 INST ALLA TION COMBUSTIBLE MANTELS CLEARANCES The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams on page 8): WARNING: Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. ...

  • Regency P121RC - page 10

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 10 B C A FRAMING AND FINISHING CAUTION: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is 0" to the standoffs so combustible building materials can be laid directly on top of the standoffs. You must maintain clearance ...

  • Regency P121RC - page 11

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 11 VENTING INTRODUCTION The P121-1/P121LC-1/P121RC-1/P131-1 uses the "balanced flue" technology Co Axial system. The inner liner vents products of com- bustion to the outside while the outer liner draws outside combustion air into the combus- tion chamber the ...

  • Regency P121RC - page 12

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 12 INST ALLA TION EXTERIOR VENT TERMINA TION LOCA TIONS . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M D F K H j V ertical T ermination V V ent terminal Area where terminal is not permited A Air supply outlet 24" V A G In ...

  • Regency P121RC - page 13

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 13 VENTING ARRANGEMENT - HORIZONT AL TERMINA TIONS Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P121-1/P121LC-1/P121RC-1/P131-1 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heat ...

  • Regency P121RC - page 14

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 14 Simpson Dura-Vent Direct Vent GS SIMPSON DURA-VENT VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from Regency. SIMPSON DURA-VENT VENTING Horizontal or Vertical Terminations The Simpson Dura-Vent Direct Vent System offers a complete ...

  • Regency P121RC - page 15

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 15 INST ALLA TION VENTING ARRANGEMENTS - HORIZONT AL TERMINA TIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (Propane & Natural Gas) The diagram below shows examples of horizontal termination arrangements using one, two, or three 90 o elbows (two 45 o elbows equal on ...

  • Regency P121RC - page 16

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 16 INST ALLA TION Diagram 3 Horizontal Venting with Two (2) 90 o Elbows Option V H + H1 A) 1' (305mm) Minimum 2' (610mm) Maximum B) 2' (610mm) Minimum 5' (1.5m) Maximum C) 3' (914mm) Minimum 8' (2.4m) Maximum D) 4' (1.22m) Minimum 11& ...

  • Regency P121RC - page 17

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 17 INST ALLA TION VENTING ARRANGEMENTS - VERTICAL TERMINA TIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (Propane & Natural Gas) • Vent must be supported at offsets • Maintain clearances to combustibles as listed on page 9. • Firestops are required at each flo ...

  • Regency P121RC - page 18

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 18 INST ALLA TION Vertical Venting with Two (2) 90 o Elbows Option V H A) 1' (305mm) Minimum 4' (1.22m) Maximum B) 2' (610mm) Minimum 6' (1.86m) Maximum C) 3' (914mm) Minimum 9' (2.7m) Maximum D) 4' (1.22m) Minimum 12' (3.6m) Max ...

  • Regency P121RC - page 19

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 19 INST ALLA TION HORIZONT AL INST ALLA TIONS Install the vent system according to the manufacturer's instructions included with the components. 1) Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venti ...

  • Regency P121RC - page 20

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 20 Diagram 3 Diagram 5 Diagram 1 Diagram 2 Note: Apply sealant "Mill-Pac" to inner pipe and high temperature sili- cone sealant to outer pipe on eve- ry twist-lock joint. VERTICAL TERMINA TION 1) Maintain the 1-1/4" clearances (air spaces) to combustible ...

  • Regency P121RC - page 21

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 21 INST ALLA TION inside each other and can be adjusted for 2 x 4 or 2 x 6 walls. The liners must slip over the collars a minimum of 1-3/8". 5) Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there ar ...

  • Regency P121RC - page 22

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 22 CONVERSION KIT FROM NA TURAL GAS T O PROP ANE MODEL #730-969 FOR P121-1/P121LC-1/P121RC-1/P131-1 USING SIT 820 NOV A GAS VAL VE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 5 ) Pull off the pilot cap to expose the p ...

  • Regency P121RC - page 23

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 23 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3 ...

  • Regency P121RC - page 24

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 24 INST ALLA TION LOG INST ALLA TION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. The gas log kit (Part # 360-930) contains the follo ...

  • Regency P121RC - page 25

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 25 INST ALLA TION 02-80 02-80 Repeat step 3 on the opposite side of the burner. Place Log 02-82 onto pin. 02-82 02-82 02-81 02-81 02-81 02-79 02-82 Grate Post 5 ) Place Log 02-82 on the middle left side of the burner. Rest the bottom of the Log onto the second grate po ...

  • Regency P121RC - page 26

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 26 GLASS DOOR REMOV AL 1 ) Remove the 8 screws that secure the glass door. INST ALLA TION 2 ) Pull the door slightly out on an angle and then lift up and pull completely out. 3 ) P131 & P121LC/P121RC Corner Model: Remove the 6 screws that secure the glass door and ...

  • Regency P121RC - page 27

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 27 Option 1: REMOTE CONTROL Can be used with Option 2 or 3 but not both. Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting pl ...

  • Regency P121RC - page 28

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 28 WIRING DIAGRAM Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring er- rors can cause improper and dangerous operation. INST ALLA TION No electric ...

  • Regency P121RC - page 29

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 29 OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the ...

  • Regency P121RC - page 30

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 30 MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacu- uming at least once a year. When cleaning the logs, use a soft clean paint ...

  • Regency P121RC - page 31

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 31 MAINTENANCE 2) Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material. 3) Check for evidences of excessive con- densation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Co ...

  • Regency P121RC - page 32

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 32 12 ) Lift the entire assembly out. 8 ) Remove the Side Base Brick Panels and finally the Long Base Brick Panels. MAINTENANCE Remove Left & Right Side Base Brick Panels Remove the 2 Long Base Brick Panels 9 ) Disconnect the inlet gas line. 10 ) Disconnect the 2 T ...

  • Regency P121RC - page 33

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 33 F AN REPLACEMENT 1) Shut off power. 2) Remove top louvers. 3) Unplug power wires. 4) Remove 4 screws securing fan to mounting bracket. MAINTENANCE 5) Remove 2 connector wires. 6) Replace fan. 7) Repeat for opposite side/corner. 8) Reverse steps 1 - 5 for installatio ...

  • Regency P121RC - page 34

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 34 P ARTS LIST P121-1 (SEE THRU) MAIN ASSEMBL Y Part # Description Part # Description Part # Description 1 ) 360-528 Door Assy Front - Tempered 360-538 Door Assy Front - Ceramic (Optional) 2 ) 360-529 Door Assy Side - Tempered 360-539 Door Assy Side - Ceramic (Optional ...

  • Regency P121RC - page 35

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 35 P ARTS LIST P131-1 (PIER) MAIN ASSEMBL Y Part # Description Part # Description Part # Description 1 ) 360-528 Door Assy Front - Tempered 360-946 Door Assy Front - Ceramic (Optional) 2 ) 360-529 Door Assy Side - Tempered 360-948 Door Assy Side- Ceramic (Optional) 9 ) ...

  • Regency P121RC - page 36

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 36 P121RC-1 (RIGHT CORNER) MAIN ASSEMBL Y Part # Description Part # Description Part # Description P ARTS LIST 1 ) 360-528 Door Assy Front - Tempered 360-538 Door Assy Front - Ceramic (Optional) 2 ) 360-529 Door Assy Side - Tempered 360-539 Door Assy Side - Ceramic (Op ...

  • Regency P121RC - page 37

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 37 P ARTS LIST P121LC-1 (LEFT CORNER) MAIN ASSEMBL Y Part # Description Part # Description Part # Description 1 ) 360-528 Door Assy Front - Tempered 360-538 Door Assy Front - Ceramic (Optional) 2 ) 360-529 Door Assy Side - Tempered 360-539 Door Assy Side - Ceramic (Opt ...

  • Regency P121RC - page 38

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 38 P121/P121LC/P121RC/P131-1 BURNER ASSEMBL Y & LOG SET Part # Description 360-930 Log Set 41) 904-326 Front Right Log 42) 904-327 Front Left Log 43) 904-328 Middle Left Log 44) 904-329 Middle Right Log 360-574/P Valve Assembly 56 ) 360-378/P Valve S.I.T. - NG 57) ...

  • Regency P121RC - page 39

    Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 39 W ARRANTY Regency Fireplace Products, are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited ...

  • Regency P121RC - page 40

    Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ...

メーカー Regency カテゴリー Indoor Fireplace

Regency P121RCのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- P121RCの取扱説明書
- Regencyの製品カード
- パンフレット
- またはRegency P121RCの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Regency P121RCの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Regency P121RCの取り付け説明書、サービスマニュアル、簡易説明書、またはRegency P121RCのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Regency P121RCの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Regency P121RCデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRegency P121RCを使用するのを助ける技術的文書のことです。説明書は通常、全てのRegency P121RCユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Regencyの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Regency P121RCの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRegency P121RCの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Regency P121RCに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Regency P121RCデバイスの基本機能を使うにあたってのヒント。 Regency P121RCのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Regency P121RCに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRegency P121RCのメーカー/サービスへの連絡先に関する情報。

Regency P121RCについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRegency P121RCの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRegency P121RCで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)