Chicago Electric 95380の取扱説明書

18ページ 1.05 mb
ダウンロード

ページに移動 of 18

Summary
  • Chicago Electric 95380 - page 1

    ROUTER T ABLE WITH ROUTER Model 95380 SET UP AND OPERA TING INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2006 by Harbor Freight T ools ® . All rights reserved. No portion of this manual or any artwork co ...

  • Chicago Electric 95380 - page 2

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 2 SPECIFICA TIONS Motor 1 10 V AC / 60 Hz / 1 1 A / 1-3/4 HP / 20,000 Maximum RPM Router T ype Plunge Router with Brake Router Power Cord SJT 16 AWG x 2C Router T able Power Switch Rocker (ON/OFF) with Safety Key Router T able Power Cord 16 A WG 3C Router T able Power Plug 3-Prong ...

  • Chicago Electric 95380 - page 3

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 3 ELECTRICAL SAFETY 1. Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way . Do not use any adapter plugs. Check with a qualied electrician if yo ...

  • Chicago Electric 95380 - page 4

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 4 7. Use safety equipment. Always wear ANSI-approved safety impact eye goggles. Dust mask or respirator , and hearing protection must be used for appropriate conditions. T OOL USE AND CARE 1. Do not force the Router . Use the correct tool for your application. The correct tool will ...

  • Chicago Electric 95380 - page 5

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 5 SPECIFIC SAFETY RULES 1. Maintain labels and nameplates on the Router and its T able. These carry important information. If unreadable or missing, contact Harbor Freight T ools for a replacement. 2. A void unintentional starting. Make sure you are prepared to begin work before tu ...

  • Chicago Electric 95380 - page 6

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 6 17. Never cut pieces too small to be held securely against the T able’ s Fence without leaving enough space for the hand to be a safe distance from the Router Bit (not included) . 18. Make sure the T able and surrounding area are clear with the exception of the workpiece to be ...

  • Chicago Electric 95380 - page 7

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 7 examples of these chemicals are: lead from lead-based paints, crystalline silica from bricks and cement or other masonry products, arsenic and chromium from chemically treated lumber . Y our risk from these exposures varies, depending on how often you do this type of work. T o re ...

  • Chicago Electric 95380 - page 8

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 8 3. The tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in the following illustration. (See 3-Prong Plug and Outlet.) THE ROUTER T ABLE POWER CORD USES A 3-PRON ...

  • Chicago Electric 95380 - page 9

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 9 ASSEMBL Y INSTRUCTIONS Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram on pages 16 and 17 . CAUTION! Always make sure the Power Switch (2B) of the Router T able is in its “OFF” position and the unit is unplugge ...

  • Chicago Electric 95380 - page 10

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 10 T o Mount The Router T able On A Workbench: 1. CAUTION! Make sure the Router T able is securely attached to a dry , at, level, sturdy workbench surface capable of supporting the weight of the unit, accessories, and workpieces. 2. At the bottom of each of the four Legs (1B) of ...

  • Chicago Electric 95380 - page 11

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 1 1 T o Connect A V acuum Hose T o The Dust Port: Figure C DUST PORT (1-3/8” OUTSIDE DIAMETER) The Dust Port of the Router T able is 1-3/8” O.D. (outside diameter) and is located at the rear of the Router T able. Use an automotive hose clamp (not included) to secure an appropri ...

  • Chicago Electric 95380 - page 12

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 12 T o Install A Router Bit: 1. W ARNING! Make sure the Power Switch of the Router T able is in its “OFF” position and the Router T able is not plugged into an electrical outlet. 2. Fully insert the Router Bit (not included) into the Collet Chuck (5A). Firmly tighten the Collet ...

  • Chicago Electric 95380 - page 13

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 13 BASIC OPERA TING INSTRUCTIONS W ARNING! Use safety equipment. Always wear ANSI- approved safety impact eye goggles. Dust mask or respirator , and hearing protection must be used for appropriate conditions. 1. Make sure the Power Switch of the Router T able is in its “OFF” po ...

  • Chicago Electric 95380 - page 14

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 14 TROUBLESHOOTING Problem Possible Solution Router will not run. 1. Make sure the Power Switch of the Router T able is in its “ON” position. 2. Make sure the Power Switch of the Router is in its “ON” position. 3. Make sure the Power Cord of the Router is connected to the P ...

  • Chicago Electric 95380 - page 15

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 15 INSPECTION, MAINTENANCE, AND CLEANING 1. CAUTION! Always make sure the Power Switch of the Router T able is in its “OFF” position and the Router T able is unplugged from its electrical outlet prior to performing any inspection, maintenance, or cleaning procedures. 2. Before ...

  • Chicago Electric 95380 - page 16

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 16 P ARTS LISTS & ASSEMBL Y DIAGRAMS P ARTS LIST & ASSEMBL Y DIAGRAM A - ROUTER Part Description Qty . 1A Machine Screw 2 2A T emplate Guide 1 3A Base Assy . 1 4A Nut Clamp 1 5A Collet Chuck 1 6A Lock Piece 1 7A Lock Screw 1 8A Lock Lever 1 9A E-T ype Retaining Ring 2 10A M ...

  • Chicago Electric 95380 - page 17

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 17 P ARTS LIST & ASSEMBL Y DIAGRAM B - ROUTER T ABLE Part Description Qty . 1B Leg 4 2B Power Switch/Outlets 1 3B Fixed Stand 1 4B Guiding Groove 1 5B Work T able 1 6B Fence 1 7B Knob 3 8B Guard 1 9B Adjustable Fence 1 10B Wrench (21mm) 1 11 B Wrench (24mm) 1 12B Miter Gauge 1 ...

  • Chicago Electric 95380 - page 18

    SKU 95380 For technical questions, please call 1-800-444-3353 P AGE 18 LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days fr ...

メーカー Chicago Electric カテゴリー Router

Chicago Electric 95380のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 95380の取扱説明書
- Chicago Electricの製品カード
- パンフレット
- またはChicago Electric 95380の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Chicago Electric 95380の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Chicago Electric 95380の取り付け説明書、サービスマニュアル、簡易説明書、またはChicago Electric 95380のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Chicago Electric 95380の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Chicago Electric 95380デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがChicago Electric 95380を使用するのを助ける技術的文書のことです。説明書は通常、全てのChicago Electric 95380ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Chicago Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Chicago Electric 95380の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははChicago Electric 95380の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Chicago Electric 95380に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Chicago Electric 95380デバイスの基本機能を使うにあたってのヒント。 Chicago Electric 95380のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Chicago Electric 95380に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるChicago Electric 95380のメーカー/サービスへの連絡先に関する情報。

Chicago Electric 95380についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもChicago Electric 95380の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがChicago Electric 95380で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)