-
Brada Appliances YPL3-08C - page 1
Port able A ir Condi tioner Instruc tion Manual YPL3 - 08C Please r ead the i nstruc tions compl etely before usi ng this product This pr oduct is d esigned for househ old use o nly . FOR SER VICE : CALL TRANS GLOBA L SER VICE 1 - 800 - 360 - 2742 2011.02.21 受控 ...
-
Brada Appliances YPL3-08C - page 2
2 CONTENT INTRODUCT ION …................ ............... .............. .............. ............. .............. 2 S AF E T Y … ......................... .............. ........... ................ .............. ............ .............. . 5 INST A LL A T ION …..................... ............ ................ .............. ......... ...
-
Brada Appliances YPL3-08C - page 3
3 INTR ODU CTION Thank you for choos ing Our Portable Air Conditio ner . Please r ead this m anual ca refully bef ore using t his product. The f ollowing tips m ay help to m aximize th e efficienc y of your air c onditioner : • W hen the air condit ioner is on, keep door s and windo ws c losed. • Turn of f kitchen or bathr oom exhaust fans when ...
-
Brada Appliances YPL3-08C - page 4
4 IMPORT A NT SAFEGUARDS W hen using electr ical applianc es, basic safet y precautions s hould al ways be f ollowed: 1. Read all i nstructio ns 2. T o protect aga inst fire, e lectric shock and personal injury , do not imm erse c ord, plugs, or the unit in water or other liqu id. 3. Close su pervision is neces sary when th e product is used aro un ...
-
Brada Appliances YPL3-08C - page 5
5 LCDI POWER CO RD A ND PL UG This air c onditioner is equipped with an LC DI (Leak age Current Detect ion and Inte rruption) power cor d and plug. T he LCDI power cord and plug wil l shut off the su pply source via electr ical d isconnect ( circuit tr ip) if the nominal c urrent leak age be tween the c ord shiel d and e ither load c onductor excee ...
-
Brada Appliances YPL3-08C - page 6
6 SAFETY PLEA SE READ A LL THESE IN S TRUC TION S CA REFULL Y BEF O RE U S I NG THIS A PPLIA NC E Only use this ap plian ce for do mestic pur poses and in the w ay indi cated i n these instruct ions. N ever use for any ot her pur poses. Do not use the ap pliance outsi de and alw ays place it i n a dry envir onment. From ti me to ti me, ...
-
Brada Appliances YPL3-08C - page 7
7 Plug i nto the wal l socket be fore swi tching on the a pplia nce then pr ess on the ON /OFF button. THE MANUF A CTURER WIL L NOT A SS UME A NY RESPONSI BILITY IN CA SE OF NON ADHERENCE TO THESE INS TRUCTIONS. RE AD THIS USER MANU AL C AREFULL Y . INST ALLA T ION Sele ction of i nst allati on location Keep th e unit on a flat su rface and dry ...
-
Brada Appliances YPL3-08C - page 8
8 Inco rr ect m oun ting The be nd o f the ex hau st pi pe i s very im po rtant. I nc o rr ect mounting c an prev en t t he machi ne from wo rk ing co rr ectly . T ake care to prev en t an y sharp bo ws or be nd s of the ex hau st pipe. The ex hau s t air must flow fr ee ly 。 W ARNING The l en gth of the exha us t pipe is specia ll y de s ig ned ...
-
Brada Appliances YPL3-08C - page 9
9 9. Handle B ac k 10. Exhaust air ou tlet v en t 1 1. Po wer cord 12. Big f il ter 13. Sma ll f il ter 14. Draining hole C hec k a ll t he acc es sori es i nc l ud ed in t he package and pl eas e refer to t he insta ll ati on i ns tructi on s for t he ir us age. A ccessories Exhaust pipe Adapter Wi nd ow slider kit A Wi nd ow slider ki t B 14 13 1 ...
-
Brada Appliances YPL3-08C - page 10
10 CONTR OL P AN EL 1. POW ER button : press this butto n to turn on/of f the unit. 2. MO DE button: press thi s button to select Cooling , Automat ic adju sting mod e or Fan mo de 3. SPEED button: pr ess thi s button t o select high, low fan speed 4. T imer: when st and - by time press this key to set aut omatic time o n; w hen running time press ...
-
Brada Appliances YPL3-08C - page 11
1 1 RE MOTE CONTROL 1. Po wer 2. Celsi us a nd F ah r en he i t exch an g e bu tton 3. Fan bu tt on 4. Cool Mo de Bu tton 5. Au to mode bu tt on 6. Down bu tton 7. Up bu tton 8. Hi gh fan spe ed bu tton 9. Low fan sp eed bu tton 10 . Max cool bu tton 1 1. Sleep Mode 12 . Timer bu t ton 10 12 8 9 7 6 5 4 3 2 1 1 1 ...
-
Brada Appliances YPL3-08C - page 12
12 OPERA TI ON METHODS Cooling mode Defau lt Cool mode afte r oper ati ng the machi ne or p ress M ode button to c hoose C ool mode , the Cool mo de indicator will fla sh. ·Press UP or DO W N b utton to set roo m temp er atur e betw een 17 ℃ t o 30 ℃ . ·Press FA N SPEED button (or High/L ow butto n) to sel ect high, l ow fa n speed. Fan mode ...
-
Brada Appliances YPL3-08C - page 13
13 W A T E R D R AI N AG E This pro duct has a sel f - evapor ative sy stem. The con densing water will be recy cled to cool the cond enser . Thi s can no t only improv e cooling ef ficiency , but also save energ y for y ou. · If t he inside w ater is full, t he display panel will display “ FL ”, and t he compr essor w ill stop running . ·Ple ...
-
Brada Appliances YPL3-08C - page 14
14 End of season ·Please drain the water . ·Keep th e unit run ning in Fan mo de for two hours until t he insi de of the u nit is dr y . ·T urn of f the unit and unpl ug it. ·Clean t he air filter an d aft er dry it thoroug hly , rei nstall it. ·Remove t he ex haust pipes and kee p them c arefully . · Wrap the uni t with t he plast ic bag and ...
Brada Appliances YPL3-08Cについてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもBrada Appliances YPL3-08Cの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBrada Appliances YPL3-08Cで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。