  • Uni-T UT371 - page 1

    M odel UT371/372 OPERA TI NG M ANUAL ...

  • Uni-T UT371 - page 2

    T ABLE OF CONTENTS TITLE P AGE 3 3 4 5 6 7 8 9 1 1 13 13 15 17 Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Setup Display Symbols Measurement Operation A. RPM Measurement B. Counts C. Data T ransferring and USB Model UT371/372: OPERA TING MANUAL 1 ...

  • Uni-T UT371 - page 3

    T ABLE OF CONTENTS TITLE P AGE 18 18 19 20 20 20 21 21 22 Specifications A. General Specifications B. Environmental Requirements Accuracy Specifications A. RPM B. Counts Maintenance A. General Service B. Replacing the Battery Model UT371/372: OPERA TING MANUAL 2 ...

  • Uni-T UT371 - page 4

    Model UT371 and UT372 is a stable, safe and reliable digital non-contact T achometer . This T achometer can measure RPM and counts. RPM range is 10 ~ 99999 while counts range is 0 ~ 99999. Open the package case and take out the Meter . Check the following items carefully to see any missing or damaged part: Description English Operating Manual Refle ...

  • Uni-T UT371 - page 5

    In the event you find any missing or damage, please contact your dealer immediately . This Meter complies with the standards IEC61010-031, IEC61326, : in pollution degree 2 Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired. In this manual, a W arning identifies conditions and ac ...

  • Uni-T UT371 - page 6

    Rules For Safe Operation Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Do not use or store the Meter in an environment of high temperature, humidity , explosive, inflammable and strong magnetic field. The performance of the Meter may d ...

  • Uni-T UT371 - page 7

    Soft cloth and mild detergent should be used to clean the surface of the Meter when servicing. No abrasive and solvent should be used to prevent the surface of the Meter from corrosion, damage and accident. T urn the Meter off when it is not in use and take out the battery when not using for a long time. Constantly check the battery as it may leak ...

  • Uni-T UT371 - page 8

    Figure 1 The Meter Structure (see figure 1) T achometer Light Source. LCD Display . USB Port (UT372 only) Housing Functional Buttons Model UT371/372: OPERA TING MANUAL 7 ...

  • Uni-T UT371 - page 9

    Functional Buttons Below table indicated for information about the functional button operations. Button Operation Performed l Press once to turn the meter on. l Press and hold for 1 minute to turn it off. l When measuring RPM and Counts, press once to enter the Hold mode. Press it again to exit hold mode. l When measuring RPM and Counts, press it t ...

  • Uni-T UT371 - page 10

    Setup A. USB setup Press R/C button to select USB feature after turning on the Meter . Then press M/M/A button to setup 0 or 1. 0 means turn the USB off. 1 means enable the USB feature. B. LED setup Press R/C button to select LED feature after turning on the Meter . Then press M/M/A button to setup 0 or 1. 0 means turn the LED laser off. 1 means en ...

  • Uni-T UT371 - page 11

    if you do not press any button for 10 minutes. Y ou could press ON/OFF button to turn on the Meter again after the Meter is off. E. CLK setup Press R/C button to select CLK feature after turning on the Meter . Then press M/M/A button to setup 0 or 1. 0 is hours and minutes format. 1 is minutes and seconds format. Model UT371/372: OPERA TING MANUAL ...

  • Uni-T UT371 - page 12

    Display Symbols (see figure 2) Figure 2 Model UT371/372: OPERA TING MANUAL 1 1 ...

  • Uni-T UT371 - page 13

    1 2 3 4 5 6 7 8 9 10 1 1 12 Unit of T achometer Unit of Counts T ime The battery is low . Indicator of Sleep Mode Measurement of RPM and Counts Data Hold is on Display of Maximum reading Display of Minimum reading Display of Average reading USB is on Display of Measurement reading l Number Meaning Model UT371/372: OPERA TING MANUAL 12 ...

  • Uni-T UT371 - page 14

    W arning W arning T o reserve battery , the USB feature will be automatically off when the Meter is restarted. The other setting remains unchanged. The Time will be off after the HOLD feature is enabled. The time will be on again after existing HOLD mode. l l A. RPM Measurement (see figure 3) l Do not point laser directly at eye. l When carrying ou ...

  • Uni-T UT371 - page 15

    Figure 3 T o carry out RPM measuremnet, follow the following procedure: Apply a piece of reflecting tape to the object under test. Position the Meter on a flat place. Hold the Meter 50~200mm from the T achometer light source to the object under test. Press ON/OFF button, the Meter is default to enter the RPM measurement mode. Point the T achometer ...

  • Uni-T UT371 - page 16

    Figure 4 B. Counts Self-lighted Counts (see figure 4) 1. Position the Meter on a flat place. Hold the Meter 50~200mm and at the vertical angel not greater than 30° from the T achometer light source to the object under test. 2. Press the ON/OFF button 3. Press the R/C button to select Count mode. 4. Point he T achometer light source to the object u ...

  • Uni-T UT371 - page 17

    Receiving Light Source Outside (see figure 5) Figure 5 Position the Meter on a flat place. Hold the Meter 50~200mm and at the vertical angel not greater than 30° from the T achometer light source to the object under test. Set up the Meter , object under counts and outside light source as figure 5 Press ON/OFF button T urn the LED off, refer to pag ...

  • Uni-T UT371 - page 18

    Figure 6 C. Data T ransferring and USB (UT372 only , see figure 6) Connect the USB interface cable, the Meter and the computer as per the figure 6. Model UT371/372: OPERA TING MANUAL 17 ...

  • Uni-T UT371 - page 19

    A. General Specifications l Display: 5 digits LCD display , Maximum display 99999. l Overloading: Display OL . l Battery Deficiency: Display . l Sampling Rate: 5 mini-second to 255 mini seconds adjustable. l T ransducer T yype: Photo Diode and Laser l Measurement Distance: 50mm ~ 200mm l Drop T est: one meter l Power: 4pcs x 1.5V batteries (AA) l D ...

  • Uni-T UT371 - page 20

    B. Environmental Requirements l For indoor use only . l Altitude: 2000m l T emperature and humidity: Ø Operating: 0 o C~30 o C( 85%R.H) 30 o C~40 o C ( 75%R.H) 40 o C~50 o C ( 45%R.H) Ø Storage: -20 o C~ +60 o C( 85%R.H) l Safety/ Compliances: IEC61010-031, IEC61326, IEC 61010-1 pollution degree 2. l Certification: Model UT371/372: OPERA TING MAN ...

  • Uni-T UT371 - page 21

    Accurate Specifications Accuracy: (a% reading + b digits), guarantee for 1 year . Operating temperature: 23 o C 5 o C Operating humidity: 80%RH T emperature Coefficient: 0.1 x (accuracy) / o C Range Resolution Accuracy 10~99.999 r/min 100~999.99 r/min 1000~9999.9 r/min 10000~99999 r/min 0.001 r/min 0.01 r/min 0.1 r/min 1 r/min (0.04%+2) A. RPM B. C ...

  • Uni-T UT371 - page 22

    MAINTENANCE This section provides basic maintenance information including battery replacement instruction. W arning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information. Do not attempt to open the back housing to avoid damaging to the Meter or a ...

  • Uni-T UT371 - page 23

    B. Replacing the Battery (see figure 7) Figure 7 1. Press ON/OFF to turn the Meter off. 2. T urn the Meter’s front case down. 3. Remove the screw from the battery door , and separate the battery door from the case bottom. 4. T ake out the old battery and replace with 4 x 1.5V battery (AA). 5. Rejoin the case bottom and the battery compartment, an ...

  • Uni-T UT371 - page 24

    * END * This operating manual is subject to change without notice. Model UT371/372: OPERA TING MANUAL 23 ...

  • Uni-T UT371 - page 25

    Copyright 2007 Uni-T rend Group Limited. All rights reserved. Manufacturer: Uni-T rend T echnology (Dongguan) Limited Dong Fang Da Dao Bei Shan Dong Fang Industrial Development District Hu Men T own, Dongguan City Guang Dong Province China Postal Code: 523 925 Headquarters: Uni-T rend Group Limited Rm901, 9/F , Nanyang Plaza 57 Hung T o Road Kwun T ...

メーカー Uni-T カテゴリー Tachometer

Uni-T UT371のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- UT371の取扱説明書
- Uni-Tの製品カード
- パンフレット
- またはUni-T UT371の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Uni-T UT371の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Uni-T UT371の取り付け説明書、サービスマニュアル、簡易説明書、またはUni-T UT371のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Uni-T UT371の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Uni-T UT371デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUni-T UT371を使用するのを助ける技術的文書のことです。説明書は通常、全てのUni-T UT371ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Uni-Tの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Uni-T UT371の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUni-T UT371の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Uni-T UT371に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Uni-T UT371デバイスの基本機能を使うにあたってのヒント。 Uni-T UT371のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Uni-T UT371に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUni-T UT371のメーカー/サービスへの連絡先に関する情報。

Uni-T UT371についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUni-T UT371の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUni-T UT371で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)