Lincoln Electric RANGER SVM120-Aの取扱説明書

133ページ 1.99 mb
ダウンロード

ページに移動 of 133

Summary
  • Lincoln Electric RANGER SVM120-A - page 1

    SVM120-A March 1999 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation . . . and thoughtful operation on your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WITHOUT READ- ING THIS MANUAL AND THE SAFETY PRECAUTIO ...

  • Lincoln Electric RANGER SVM120-A - page 2

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY i i FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated a ...

  • Lincoln Electric RANGER SVM120-A - page 3

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY ii ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. U ...

  • Lincoln Electric RANGER SVM120-A - page 4

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY iii iii FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufactu ...

  • Lincoln Electric RANGER SVM120-A - page 5

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY iv iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour ...

  • Lincoln Electric RANGER SVM120-A - page 6

    MASTER T ABLE OF CONTENTS FOR ALL SECTIONS v v RANGER 10-LX Page Safety .................................................................................................................................................i-iv Installation ................................................................................................................... ...

  • Lincoln Electric RANGER SVM120-A - page 7

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 RANGER 10-LX Installation T echnical Specifications .............................................................................................................A-2 Safety Precautions ............ ...

  • Lincoln Electric RANGER SVM120-A - page 8

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-2 A-2 RANGER 10-LX TECHNICAL SPECIFICA TIONS - RANGER 10-LX INPUT - DIESEL ENGINE Manufacturer Description Speed Displacement Ignition Capacities KUBOT A 3 cyl., ...

  • Lincoln Electric RANGER SVM120-A - page 9

    Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly r ead all the operation and maintenance manuals supplied with your machine. They include important safety precautions; detailed engine starting, operating, and maintenance instructions; and parts lis ...

  • Lincoln Electric RANGER SVM120-A - page 10

    ST ACKING RANGER 10-LX machines CANNOT be stacked. TIL TING Place the machine on a secure, level surface whenev- er you use it or store it. Any surfaces you place it on other than the ground must be firm, non-skid, and structurally sound. The diesel engine is designed to run in a level position for best performance. It can operate at an angle, but ...

  • Lincoln Electric RANGER SVM120-A - page 11

    MUFFLER RELOCA TION Shut off the machine and allow the muf fler to cool before touching the muf fler . The RANGER 10-LX is shipped with the exhaust directed towar d the rear . It can be changed to the right side by loosening the clamp that holds the exhaust deflector in place and rotating the deflector to the desired dir ection. SP ARK ARRESTER Die ...

  • Lincoln Electric RANGER SVM120-A - page 12

    WELDING CABLE CONNECTIONS CABLE SIZE AND LENGTH Be sure to use welding cables that ar e lar ge enough. The correct size and length becomes especially impor- tant when you are welding at a distance fr om the welder . T able A.1 lists recommended cable sizes and lengths for rated current and duty cycle. Length r efers to the distance from the welder ...

  • Lincoln Electric RANGER SVM120-A - page 13

    When the RANGER 10-LX is mounted on a truck or a trailer , the machine generator ground stud MUST be secur ely connect- ed to the metal frame of the vehicle. See Figure A.1. The gr ound stud is marked with the ground symbol. If the RANGER 10-LX is connected to premises wiring such as a home or shop, it must be properly connect- ed to the system ear ...

  • Lincoln Electric RANGER SVM120-A - page 14

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-8 A-8 RANGER 10-LX LOAD 230 V olt 60 Hz. 3-Wire Ser vice 230 V OL T GROUNDED CONDUCT OR 115 V OL T 115 V OL T PO WER COMP ANY METER DOUBLE POLE DOUBLE THRO W S W ...

  • Lincoln Electric RANGER SVM120-A - page 15

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section B-1 Section B-1 RANGER 10-LX T ABLE OF CONTENTS - OPERA TION SECTION - Operation ............................................................................................................................... Section B Safety Instructions ................... ...

  • Lincoln Electric RANGER SVM120-A - page 16

    OPERA TING INSTRUCTIONS Read and understand this entire section befor e oper- ating your RANGER 10-LX. SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have thoroughly r ead all the operation and maintenance manuals supplied with your machine. They include important safety precautions; detailed engine starting, operating, and main ...

  • Lincoln Electric RANGER SVM120-A - page 17

    RECOMMENDED APPLICA TIONS WELDER The RANGER 10-LX provides excellent constant cur- rent AC/DC welding output for stick (SMA W) welding and for TIG welding, and it offers constant voltage out- put for DC semiautomatic wire feed welding. For mor e details on using the machine as a welder , see W elding Operation in the Operation section of this manua ...

  • Lincoln Electric RANGER SVM120-A - page 18

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-4 B-4 RANGER 10-LX FIGURE B.1 – OUTPUT P ANEL CONTROLS 1. OUTPUT RANGE SELECTOR 2. FINE OUTPUT CONTROL 3. POLARITY SWITCH 4. CONTROL A T WELDER/REMOTE CONTROL SWIT ...

  • Lincoln Electric RANGER SVM120-A - page 19

    7. 20 AMP , 115 VOL T DUPLEX RECEPT ACLES: Connection point for supplying 115 volt power to operate one or two electrical devices. 8. 50 AMP , 230/115 VOL T RECEPT ACLE: Connection point for supplying 230 volt power to operate one electrical device. 9. WELD OUTPUT TERMINAL (TO WORK) WITH FLANGE NUT : Provides the connection point for the work cable ...

  • Lincoln Electric RANGER SVM120-A - page 20

    DIESEL ENGINE CONTROLS See Figure B.2 for the location of the following fea- tures: 1. GLOW PLUG PUSHBUTTON: Acti- vates glow plugs to preheat engine for starting. 2. IDLER CONTROL SWITCH: Adjusts the running speed of the engine. The switch has two posi- tions, HIGH and AUTO. In HIGH, the engine runs continuously at high idle. In AUTO, the idler co ...

  • Lincoln Electric RANGER SVM120-A - page 21

    6. OIL PRESSURE LIGHT : Remains off with proper oil pr essure. If light turns on, the engine protection system will stop the engine. The light will go on when the “Engine” switch is switched to the “ON” position with engine not running. It will go off after one minute if the engine is not started. 7. WA TER TEMPERA TURE LIGHT : Remains off ...

  • Lincoln Electric RANGER SVM120-A - page 22

    ST ARTING THE ENGINE NOTE: Remove all loads connected to the AC power receptacles befor e starting the diesel engine. 1. Open the engine compartment door and check that the fuel shutoff valve located above the clear plastic fuel filter housing is in the open position (lever in the vertical position). See Figure B.3. 2. Check for proper level of coo ...

  • Lincoln Electric RANGER SVM120-A - page 23

    OPERA TION B-9 B-9 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE B.1 TYPICAL RANGER 10-LX FUEL CONSUMPTION KUBOT A DH850-B-88 Low Idle – No Load, 2150 RPM .30 Gallons/hour (1.0 liters/hour) High Idle ? ...

  • Lincoln Electric RANGER SVM120-A - page 24

    WELDING OPERA TION GENERAL INFORMA TION • Do not touch electrically live parts or elec- trodes with your skin or wet clothing. • Do not breathe welding fumes or gases. • Use ventilation or exhaust to remove welding fumes from the br eathing area. • Keep flammable material away . • W ear eye, ear , and body protection. The RANGER 10-LX can ...

  • Lincoln Electric RANGER SVM120-A - page 25

    T o Use the RANGER 10-LX for AC/DC TIG (Constant Current) Welding: 1. Connect the K930-1 TIG Module to the RANGER 10-LX. Follow the installation instructions provid- ed with the kit. Also be sure to follow the special machine grounding instructions given in the man- ual. 2. Refer to the instruction manual with the TIG mod- ule (IM 528) for operatio ...

  • Lincoln Electric RANGER SVM120-A - page 26

    T o Use the RANGER 10-LX for DC Wire Feed Welding (Constant V oltage): 1. Connect one of the following: the LN-25, LN-7 or LN-8 Wire Feeder . Follow the installation instruc- tions in the Accessories section of this manual. 2. Some recommended Innershield electrodes are: NR-211MP , NR-311, NR-203 series, as well as Lincore ® 33 and 55 har dfacing ...

  • Lincoln Electric RANGER SVM120-A - page 27

    SUMMAR Y OF WELDING PROCESSES AND MACHINE SETTINGS T able B.3 summarizes the requir ements for various welding processes you can perform with the RANGER 10-LX. OPERA TION B-13 B-13 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Retur ...

  • Lincoln Electric RANGER SVM120-A - page 28

    AUXILIAR Y POWER Be sure that any electrical equipment plugged into the generator AC power receptacles can withstand a ±10% voltage and a ±3% frequency variation. GENERAL INFORMA TION The RANGER 10-LX generator is rated at 10,000 con- tinuous watts. It provides both 115 volt and 230 volt power . Y ou can draw up to 87 amps total, but no more than ...

  • Lincoln Electric RANGER SVM120-A - page 29

    OPERA TION B-15 B-15 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE B.4 - SIMUL T ANEOUS WELDING AND AUXILIARY POWER Output Selector Welding Permissible Power in W atts Permissible Auxiliary Curr ent Setti ...

  • Lincoln Electric RANGER SVM120-A - page 30

    T ABLE B.5 TYPICAL GENERA TOR POWER APPLICA TIONS Suggested Power Applications Running W atts *Start-up Watts *Air Compressor - 3/4 HP 1,250 3,100 - 5,000 *Airless Sprayer - 1/3 HP 600 1,500 - 2,400 Chain Saw 1,200 Circular Saw 1,200 Coffee Maker 1,000 *Deep Freezer 500 750 - 2,000 *Electric Motor - 1 HP 1,000 2,500 - 4,000 Electric Range (1 elemen ...

  • Lincoln Electric RANGER SVM120-A - page 31

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE OF CONTENTS - ACCESSORIES - Accessories ........................................................................................................................... Section C Options/Accessories.................................................................. ...

  • Lincoln Electric RANGER SVM120-A - page 32

    OPTIONS/ACCESSORIES The following options/accessories are available for your RANGER 10-LX from your local Lincoln Distributor . T wo-Wheel T railer (K768) – For in-plant or yard tow- ing of the RANGER 10-LX. (Not intended for highway towing as equipped. For highway use of this trailer , consult applicable federal, state, and local laws about poss ...

  • Lincoln Electric RANGER SVM120-A - page 33

    TIG WELDING TIG Module (K930-1) - The TIG Module is an acces- sory that provides high fr equency and shielding gas control for AC and DC GT A W (TIG) welding applica- tions. It provides contactor contr ol of constant curr ent welding power sources having an internal contactor . The K930-1 TIG Module is supplied without accessories. Arc Start switch ...

  • Lincoln Electric RANGER SVM120-A - page 34

    ELECTRIC SHOCK can kill. • Do not operate with panels open. • Disconnect NEGA TIVE (-) BA TTER Y LEAD before servicing. • Do not touch electrically live parts. MOVING P ARTS can injure. • Keep guards in place. • Keep away from moving parts. • Only qualified personnel should install, use or service this equipment. CONNECTION OF THE RANGE ...

  • Lincoln Electric RANGER SVM120-A - page 35

    7. Place the WIRE FEEDER switch in the “WITH CON- TROL CABLE” position. 8. Adjust wire feed speed at the wir e feeder and set the welding voltage with the output “CONTROL” to a CV (constant voltage) position at the welder . NOTE: If optional remote contr ol is used, place the output control switch in the “CON- TROL REMOTE” position. CON ...

  • Lincoln Electric RANGER SVM120-A - page 36

    ACCESSORIES C-6 C-6 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-7 TO THE RANGER 10-LX USING K584 INPUT CABLE ASSEMBL Y (SEE FIGURE C.3.) NOTE: If your LN-7 comes equipped with a K291 or K4 ...

  • Lincoln Electric RANGER SVM120-A - page 37

    ACCESSORIES C-7 C-7 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-7 TO THE RANGER 10-LX USING K867 UNIVERSAL ADAPTER (SEE FIGURE C.4.) 1. Shut the welder off. 2. Connect the electrode cable ...

  • Lincoln Electric RANGER SVM120-A - page 38

    ACCESSORIES C-8 C-8 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-8 TO THE RANGER 10-LX (SEE FIGURE C.5.) 1. Shut the welder off. 2. Connect the electrode cable from the LN-8 to the “ELECT ...

  • Lincoln Electric RANGER SVM120-A - page 39

    ACCESSORIES C-9 C-9 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE K488 SG CON- TROL MODULE AND K487 MAGNUM SPOOL GUN TO THE RANGER 10-LX (SEE FIGURE C6.) 1. Shut the welder off. 2. Connect the ...

  • Lincoln Electric RANGER SVM120-A - page 40

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section D-1 Section D-1 RANGER 10-LX T ABLE OF CONTENTS -MAINTENANCE- Maintenance ......................................................................................................................... Section D Safety Precautions.................................. ...

  • Lincoln Electric RANGER SVM120-A - page 41

    SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • T urn the engine off before working inside the machine. • Remove covers or guards only when necessary to perform maintenance and replace them when the maintenance requiring their r emoval is complete. • If covers or guards ar e missing from the mach ...

  • Lincoln Electric RANGER SVM120-A - page 42

    CHANGE THE OIL FIL TER Change the oil filter the first time after 50 hours of operation. Then, under normal operating conditions, change the oil filter after every 200 hours of operation. If the engine is operated under heavy load or in high ambient temperatures, change the oil filter mor e fre- quently . See T able D.1 for recommended mainte- nanc ...

  • Lincoln Electric RANGER SVM120-A - page 43

    4. Carefully place the element back into the fuel pot. Be careful not to allow any dirt to stick to the ele- ment. 5. Reassemble the filter pot and tighten the ring scr ew at the top. 6. Open the fuel cock and loosen the two air vent plugs a few turns. When bubbles no longer appear around the plugs, scr ew them back in. 7. Bleed the fuel injection ...

  • Lincoln Electric RANGER SVM120-A - page 44

    AIR CLEANER: The Kubota diesel engine is equipped with a dry type air filter . Never apply oil to it. Service the air cleaner as follows: 1. Remove the dust cup from the bottom of the air cleaner housing. Clean out any accumulated dust. 2. If dust is sticking to the element, blow compressed air through the element fr om the inside out. T urn the el ...

  • Lincoln Electric RANGER SVM120-A - page 45

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAINTENANCE D-6 D-6 RANGER 10-LX FIGURE D.4 – COOLING SYSTEM CHECKING/ADDING/DRAINING RADIA TOR COOL- ANT : Check the level of coolant in the reserve tank. The level is suffici ...

  • Lincoln Electric RANGER SVM120-A - page 46

    MAINTENANCE D-7 D-7 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE D.1 KUBOT A ENGINE MAINTENANCE SCHEDULE FREQUENCY MAINTENANCE REQUIRED Daily or Before Starting Engine • Fill fuel tank. • Check oil l ...

  • Lincoln Electric RANGER SVM120-A - page 47

    CAUTION BA TTER Y MAINTENANCE GASES FROM BA TTER Y can explode. • Keep sparks, flame, and cigarettes away from battery . T o prevent EXPLOSION when: • INST ALLING A NEW BA TTERY - Disconnect the negative cable from the old battery first and connect to the new battery last. • CONNECTING A BA TTER Y CHARGER - Remove the battery from the welder ...

  • Lincoln Electric RANGER SVM120-A - page 48

    T o reinstall the brushes, pr ess them upward and slide a cable tie or wooden stick through the brush holder tabs. See Figure D.5. Install the brush holder into position and secure with the scr ews previously removed. Remove the cable tie or wooden stick and the brushes will seat onto the slip rings. RECEPT ACLES: Keep the electrical receptacles in ...

  • Lincoln Electric RANGER SVM120-A - page 49

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAINTENANCE D-10 D-10 RANGER 10-LX FIGURE D.6 - MAJOR COMPONENT LOCA TIONS 8 4 7 11 6 1 15 3 13 5 12 14 10 16 17 19 20 11. P .C. BOARD COVER 12. CAP ACITOR BANK 13. RADIA TOR ASS ...

  • Lincoln Electric RANGER SVM120-A - page 50

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section E-1 Section E-1 Theory of Operation ............................................................................................................. Section E Battery , Starter , Engine, Glow Plugs, Engine Protection, Rotor , Stator , and Idler Solenoid ....... ...

  • Lincoln Electric RANGER SVM120-A - page 51

    BA TTER Y , ST ARTER, ENGINE, GLOW PLUGS, ENGINE PROTECTION, ROTOR, ST A TOR AND IDLER SOLENOID The 12VDC battery powers the starter motor and glow plugs. The glow plugs are used to pr eheat the diesel engine to enhance starting., When the engine is started and running, the battery circuit voltage is fed through the printed cir cuit board to the r ...

  • Lincoln Electric RANGER SVM120-A - page 52

    ROTOR FIELD FEEDBACK, AUXILIAR Y , AND WIRE FEEDER POWER The AC voltage developed in the field winding is fed to the full wave field bridge. The DC output of the field bridge is filtered by the field capacitor and contr olled by the printed circuit boar d according to the output or remote contr ol setting. This filtered and controlled voltage is fe ...

  • Lincoln Electric RANGER SVM120-A - page 53

    WELD WINDING, REACTOR, AND RANGE SWITCH The stator weld winding is connected to the reactor and range switch. The inductance in the reactor of fers an impedance to current flow . The reactor coil is tapped at various points. As the range switch is ro- tated, differ ent amounts of reactor coil ar e brought into the current path. As mor e tur ns of r ...

  • Lincoln Electric RANGER SVM120-A - page 54

    OUTPUT BRIDGE, CHOKE, POLARITY SWITCH, CV CONT ACTOR AND OUTPUT TERMINALS The AC voltage developed in the stator weld winding is delivered, thr ough the reactor and range switch, to the output bridge and polarity switch. Depending upon the setting of the polarity switch, either AC volt- age or DC voltage is delivered to the output terminals. If AC ...

  • Lincoln Electric RANGER SVM120-A - page 55

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section F-1 Section F-1 RANGER 10-LX T roubleshooting & Repair Section ................................................................................. Section F How to Use T roubleshooting Guide ................................................................. ...

  • Lincoln Electric RANGER SVM120-A - page 56

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC HOW TO USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory T rained Personnel. Unauthorized repairs performed on this equipment may ...

  • Lincoln Electric RANGER SVM120-A - page 57

    ELECTRIC SHOCK can kill. Have an electrician install and service this equipment. T urn the machine OFF before working on equipment. Do not touch electrically hot parts. Sometimes machine failures appear to be due to PC board failur es. These problems can sometimes be traced to poor electrical connections. T o avoid prob- lems when troubleshooting a ...

  • Lincoln Electric RANGER SVM120-A - page 58

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-4 F-4 RANGER 10-LX Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not ...

  • Lincoln Electric RANGER SVM120-A - page 59

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-5 F-5 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not ...

  • Lincoln Electric RANGER SVM120-A - page 60

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-6 F-6 RANGER 10-LX Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not ...

  • Lincoln Electric RANGER SVM120-A - page 61

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-7 F-7 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not ...

  • Lincoln Electric RANGER SVM120-A - page 62

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-8 F-8 RANGER 10-LX Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not ...

  • Lincoln Electric RANGER SVM120-A - page 63

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-9 F-9 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not ...

  • Lincoln Electric RANGER SVM120-A - page 64

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-10 F-10 RANGER 10-LX Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do no ...

  • Lincoln Electric RANGER SVM120-A - page 65

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-11 F-11 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do no ...

  • Lincoln Electric RANGER SVM120-A - page 66

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-12 F-12 RANGER 10-LX TROUBLESHOOTING & REP AIR TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do no ...

  • Lincoln Electric RANGER SVM120-A - page 67

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-13 F-13 RANGER 10-LX Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS ...

  • Lincoln Electric RANGER SVM120-A - page 68

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-14 F-14 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS ...

  • Lincoln Electric RANGER SVM120-A - page 69

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-15 F-15 RANGER 10-LX TROUBLESHOO TING GUIDE Obser v e Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPT OMS) POSSIBLE AR ...

  • Lincoln Electric RANGER SVM120-A - page 70

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-16 F-16 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS ...

  • Lincoln Electric RANGER SVM120-A - page 71

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-17 F-17 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS ...

  • Lincoln Electric RANGER SVM120-A - page 72

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-18 F-18 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS ...

  • Lincoln Electric RANGER SVM120-A - page 73

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-19 F-19 RANGER 10-LX TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS ...

  • Lincoln Electric RANGER SVM120-A - page 74

    TROUBLESHOOTING & REP AIR F-20 F-20 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS ...

  • Lincoln Electric RANGER SVM120-A - page 75

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-21 F-21 RANGER 10-LX ROTOR VOL T AGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized ...

  • Lincoln Electric RANGER SVM120-A - page 76

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-22 F-22 RANGER 10-LX ROTOR VOL T AGE TEST (continued) FIGURE F .1 - LOCA TION OF LEAD 200A AND 219 FOR ROTOR VOL T AGE TEST TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. With ...

  • Lincoln Electric RANGER SVM120-A - page 77

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ROTOR RESIST ANCE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in ...

  • Lincoln Electric RANGER SVM120-A - page 78

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-24 F-24 RANGER 10-LX ROTOR RESIST ANCE TEST (continued) FIGURE F .2 – LEADS 200A AND 219 REMOVED TEST PROCEDURE 1. With the 5/16” and 3/8” n ...

  • Lincoln Electric RANGER SVM120-A - page 79

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-25 F-25 RANGER 10-LX W ARNING AUXILIAR Y AND FIELD WINDING TEST Service and repair should be performed by only Lincoln Electric factory trained pe ...

  • Lincoln Electric RANGER SVM120-A - page 80

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE T o test the 1 15 V AC winding: 1. With the 5/16” and 3/8” nut drivers, r emove the sheet metal screws fr om the left case side. 2. Carefully r emove the left ...

  • Lincoln Electric RANGER SVM120-A - page 81

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-27 F-27 RANGER 10-LX AUXILIAR Y AND FIELD WINDING TEST (continued) FIGURE F .4 – LOCA TION OF LEADS #7 AND #9 A T FIELD BRIDGE RECTIFIER T o tes ...

  • Lincoln Electric RANGER SVM120-A - page 82

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-28 F-28 RANGER 10-LX AUXILIAR Y AND FIELD WINDING TEST (continued) Z W Y X K B I H N L C D M G E F J A FIGURE F .4A – 14 PIN AMPHENOL PIN ASSIGN ...

  • Lincoln Electric RANGER SVM120-A - page 83

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-29 F-29 RANGER 10-LX W ARNING OUTPUT RECTIFIER BRIDGE TEST Service and repair should be performed by only Lincoln Electric factory trained personn ...

  • Lincoln Electric RANGER SVM120-A - page 84

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-30 F-30 RANGER 10-LX OUTPUT RECTIFIER BRIDGE TEST (continued) FIGURE F .5 – LOCA TION OF OUTPUT RECTIFIER DIODE LEADS TEST PROCEDURE 1. Using th ...

  • Lincoln Electric RANGER SVM120-A - page 85

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-31 F-31 RANGER 10-LX W ARNING CHARGING CIRCUIT TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Una ...

  • Lincoln Electric RANGER SVM120-A - page 86

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-32 F-32 RANGER 10-LX CHARGING CIRCUIT TEST (continued) FIGURE F .6 – LOCA TION OF VOL T AGE REGULA TOR TEST PROCEDURE 1. With the 5/16” and 3/ ...

  • Lincoln Electric RANGER SVM120-A - page 87

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-33 F-33 RANGER 10-LX W ARNING PROTECTION RELA Y (CR1) TEST Service and repair should be performed by only Lincoln Electric factory trained personn ...

  • Lincoln Electric RANGER SVM120-A - page 88

    TROUBLESHOOTING & REP AIR F-34 F-34 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROTECTION RELA Y (CR1) TEST (continued) FIGURE F .7 – CR1 LEAD CONNECTIONS TEST PROCEDURE 1. Using the 5/16” and 3/8” ...

  • Lincoln Electric RANGER SVM120-A - page 89

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-35 F-35 RANGER 10-LX W ARNING ENGINE THROTTLE ADJUSTMENT TEST Service and repair should be performed by only Lincoln Electric factory trained pers ...

  • Lincoln Electric RANGER SVM120-A - page 90

    TROUBLESHOOTING & REP AIR F-36 F-36 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE THROTTLE ADJUSTMENT TEST (continued) FIGURE F .8 – MARK LOCA TION, STROBE/T ACH METHOD TEST PROCEDURE This test can ...

  • Lincoln Electric RANGER SVM120-A - page 91

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-37 F-37 RANGER 10-LX ENGINE THROTTLE ADJUSTMENT TEST (continued) Adjust HIGH IDLE: First make sure ther e is NOT a load on the machine. Use the 10 ...

  • Lincoln Electric RANGER SVM120-A - page 92

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-38 F-38 RANGER 10-LX ENGINE THROTTLE ADJUSTMENT TEST (continued) Oscilloscope Method: 1. Connect the oscilloscope to the 115 VAC receptacle, accor ...

  • Lincoln Electric RANGER SVM120-A - page 93

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-39 F-39 RANGER 10-LX This is the typical auxiliary output voltage generated from a pr operly operating machine. Note that each vertical division r ...

  • Lincoln Electric RANGER SVM120-A - page 94

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-40 F-40 RANGER 10-LX This is the typical CV output voltage generated from a pr operly operating machine. Note that each vertical division repr ese ...

  • Lincoln Electric RANGER SVM120-A - page 95

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-41 F-41 RANGER 10-LX This is the typical DC output voltage generated from a pr operly operating machine. Note that each vertical division repr ese ...

  • Lincoln Electric RANGER SVM120-A - page 96

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-42 F-42 RANGER 10-LX This is the typical AC output voltage generated from a pr operly operating machine. Note that each vertical division repr ese ...

  • Lincoln Electric RANGER SVM120-A - page 97

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-43 F-43 RANGER 10-LX This is NOT the typical DC (+) output voltage waveform. One output diode is not functioning. Note the “gap” in the wavefo ...

  • Lincoln Electric RANGER SVM120-A - page 98

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-44 F-44 RANGER 10-LX This is NOT the typical CV output voltage waveform. The capacitor bank is not functioning. Note the “ripple” in the wavef ...

  • Lincoln Electric RANGER SVM120-A - page 99

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-45 F-45 RANGER 10-LX This is the typical CV output voltage generated from a pr operly operating machine. Note that each vertical division repr ese ...

  • Lincoln Electric RANGER SVM120-A - page 100

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-46 F-46 RANGER 10-LX SCOPE SETTINGS V olts/Div .....................50V/Div . Horizontal Sweep.....5 ms/Div . Coupling ........................... ...

  • Lincoln Electric RANGER SVM120-A - page 101

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-47 F-47 RANGER 10-LX CH1 0 volts 5 ms 50 volts SCOPE SETTINGS V olts/Div .....................50V/Div . Horizontal Sweep.....5 ms/Div . Coupling . ...

  • Lincoln Electric RANGER SVM120-A - page 102

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-48 F-48 RANGER 10-LX BRUSH REMOV AL AND REPLACEMENT W ARNING Service and repair should be performed by only Lincoln Electric factory trained perso ...

  • Lincoln Electric RANGER SVM120-A - page 103

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-49 F-49 RANGER 10-LX BRUSH REMOV AL AND REPLACEMENT (continued) PROCEDURE 1. Perform this procedure with the engine OFF . 2. With the 5/16” and ...

  • Lincoln Electric RANGER SVM120-A - page 104

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-50 F-50 RANGER 10-LX NOTE: A slight amount of darkening and wear of the slip rings and brushes is normal. Brushes should be inspected when a gener ...

  • Lincoln Electric RANGER SVM120-A - page 105

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-51 F-51 RANGER 10-LX W ARNING FIELD CAP ACITOR AND/OR RECTIFIER BRIDGE REMOV AL AND REPLACEMENT Service and repair should be performed by only Lin ...

  • Lincoln Electric RANGER SVM120-A - page 106

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-52 F-52 RANGER 10-LX FIELD CAP ACITOR AND/OR RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) FIGURE F .12 RECTIFIER BRIDGE LOCA TION AND DIS ...

  • Lincoln Electric RANGER SVM120-A - page 107

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-53 F-53 RANGER 10-LX FIELD CAP ACITOR AND/OR RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) PROCEDURE - RECTIFIER BRIDGE REMOV AL AND REPLA ...

  • Lincoln Electric RANGER SVM120-A - page 108

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-54 F-54 RANGER 10-LX W ARNING CONTROL BOARD REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory train ...

  • Lincoln Electric RANGER SVM120-A - page 109

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-55 F-55 RANGER 10-LX CONTROL BOARD REMOV AL AND REPLACEMENT (continued) FIGURE F .13 - CONTROL BOARD LOCA TION PROCEDURE Before starting the follo ...

  • Lincoln Electric RANGER SVM120-A - page 110

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-56 F-56 RANGER 10-LX 16. Connect curr ent sensing leads #254 and #254A. See the Wiring Diagram for the proper connections. 17. Connect the two mol ...

  • Lincoln Electric RANGER SVM120-A - page 111

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-57 F-57 RANGER 10-LX W ARNING OUTPUT RECTIFIER BRIDGE REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric fac ...

  • Lincoln Electric RANGER SVM120-A - page 112

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-58 F-58 RANGER 10-LX OUTPUT RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) FIGURE F .14 - OUTPUT RECTIFIER CONNECTIONS PROCEDURE 1. Perform ...

  • Lincoln Electric RANGER SVM120-A - page 113

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-59 F-59 RANGER 10-LX OUTPUT RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) 9. Clear the leads and carefully r emove the heat sink assembly ...

  • Lincoln Electric RANGER SVM120-A - page 114

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-60 F-60 RANGER 10-LX W ARNING OUTPUT CAP ACITOR BANK REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric fact ...

  • Lincoln Electric RANGER SVM120-A - page 115

    TROUBLESHOOTING & REP AIR F-61 F-61 RANGER 10-LX Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OUTPUT CAP ACITOR BANK EMOV AL AND REPLACEMENT (continued) FIGURE F .15 - OUTPUT CAP ACITOR BANK/PRINTED CIRCUIT BOARD LOCA T ...

  • Lincoln Electric RANGER SVM120-A - page 116

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-62 F-62 RANGER 10-LX W ARNING OUTPUT CONT ACTOR REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory t ...

  • Lincoln Electric RANGER SVM120-A - page 117

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-63 F-63 RANGER 10-LX OUTPUT CAP ACITOR REMOV AL AND REPLACEMENT (continued) FIGURE F .16 – OUTPUT CONT ACTOR LOCA TION PROCEDURE 1. Perform this ...

  • Lincoln Electric RANGER SVM120-A - page 118

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIRs F-64 F-64 RANGER 10-LX OUTPUT CAP ACITOR REMOV AL AND REPLACEMENT (continued) FIGURE F .17 – CONT ACTOR COIL LEAD PLACEMENT 224C 224F 2C 2D 14B 2 ...

  • Lincoln Electric RANGER SVM120-A - page 119

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-65 F-65 RANGER 10-LX W ARNING ST A TOR AND/OR ROTOR REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric facto ...

  • Lincoln Electric RANGER SVM120-A - page 120

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-66 F-66 RANGER 10-LX ST A TOR AND/OR REMOV AL AND REPLACEMENT (continued) FIGURE F .18 – COMPONENT LOCA TIONS, ST A TOR/ROT OR REMOV AL 7  9 ...

  • Lincoln Electric RANGER SVM120-A - page 121

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-67 F-67 RANGER 10-LX ST A TOR AND/OR ROTOR REMOV AL AND REPLACEMENT (continued) PROCEDURE (Stator Removal) 1. Perform this procedur e with the eng ...

  • Lincoln Electric RANGER SVM120-A - page 122

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-68 F-68 RANGER 10-LX 23. Using the 5/16” wrench, remove the thr ee sheet metal screws holding the fr ont vertical baffle to the base of the mach ...

  • Lincoln Electric RANGER SVM120-A - page 123

    REASSEMBL Y NOTES 1. Be sure to remove the r otor bearing from the stator frame before r einstalling the rotor/stator Also r emove the tolerance ring. 2. Install the rotor to the flex plate and install the flex plate to the engine. 3. Carefully install the stator . Tighten the eight bolts finger -tight only . 4. Install a new tolerance ring and pre ...

  • Lincoln Electric RANGER SVM120-A - page 124

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-70 F-70 RANGER 10-LX RETEST AFTER REP AIR Retest a machine: • If it is rejected under test for any r eason that requir es you to remove any mech ...

  • Lincoln Electric RANGER SVM120-A - page 125

    T ABLE OF CONTENTS - ELECTRICAL DIAGRAMS SECTION - RANGER 10LX Electrical Diagram Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section G Wiring Diagram Ranger 10 LX Code 9816 . . . . . . . . . . . . . . . . . . . . . . . G-2 Wiring Diagram Ranger 10 LX CSA Code 9821 . . . . . . . . . . . . . . . . . . . G-3 Control PC B ...

  • Lincoln Electric RANGER SVM120-A - page 126

    NOTES RANGER 10LX Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric RANGER SVM120-A - page 127

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-2 RANGER 10LX Wiring Diagram Ranger 10LX Code 9816 WORK GND R5 C6 C7 C8 C9 S2 S2 IDLER SWITCH BOARD D2 R R S6 S4 S3 SELECTOR SWITCH R1 R2 R3 R4 R5 R6 R7 C1 ...

  • Lincoln Electric RANGER SVM120-A - page 128

    G-3 ELECTRICAL DIAGRAMS RANGER 10LX Wiring Diagram Ranger 10LX CSA Code 9821 WORK GND R5 C6 C7 C8 C9 S2 S2 IDLER SWITCH BOARD D2 R R S6 S4 S3 SELECTOR SWITCH R1 R2 R3 R4 R5 R6 R7 C1 C2 C3 C4 S1 S2 REACTOR E 240 25W STATOR C1 ROTOR FIELD 800 MFD CAPACITOR (+) (-) FIELD RECTIFIER 219 200 201 (-) (+) 243 242 240 COMMON GROUND SCREW 243 HIGH AUTO " ...

  • Lincoln Electric RANGER SVM120-A - page 129

    G-4 ELECTRICAL DIAGRAMS RANGER 10LX Control PC Board (G2318) Schematic G-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level trouble ...

  • Lincoln Electric RANGER SVM120-A - page 130

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC G-5 ELECTRICAL DIAGRAMS RANGER 10LX Control PC Board (G2318) Layout G-5 NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troublesho ...

  • Lincoln Electric RANGER SVM120-A - page 131

    DIAGRAMS G-6 G-6 RANGER 10LX NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only . Lincoln Electric di ...

  • Lincoln Electric RANGER SVM120-A - page 132

    DIAGRAMS G-7 G-7 RANGER 10LX DIMENSION PRINT 18.00 17.50 12.02 5.25 3.94 18.00 18.50 24.03 24.75 N.A. N.B.  13.85 20.25 N.A. 60.18 N.B. CENTER OF GRAVITY 33.81 13.00 11.00 COOLANT CAP 5.25 31.03 34.62 46.00 60.50 31.57 M16706 3-24-95E Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Ret ...

  • Lincoln Electric RANGER SVM120-A - page 133

    SVM ERR OR REPORTING FORM W e need to know if there are errors in our manuals. W e also v alue any suggestions as to additional tests or procedures that would mak e this SVM a better tool f or you. If you disco ver ne w or diff erent “Problems or Symptoms” that are not co vered in the three col- umn troubleshooting chart, please share this info ...

メーカー Lincoln Electric カテゴリー Welder

Lincoln Electric RANGER SVM120-Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RANGER SVM120-Aの取扱説明書
- Lincoln Electricの製品カード
- パンフレット
- またはLincoln Electric RANGER SVM120-Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln Electric RANGER SVM120-Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln Electric RANGER SVM120-Aの取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln Electric RANGER SVM120-Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln Electric RANGER SVM120-Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lincoln Electric RANGER SVM120-Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln Electric RANGER SVM120-Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln Electric RANGER SVM120-Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincoln Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln Electric RANGER SVM120-Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln Electric RANGER SVM120-Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln Electric RANGER SVM120-Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln Electric RANGER SVM120-Aデバイスの基本機能を使うにあたってのヒント。 Lincoln Electric RANGER SVM120-Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln Electric RANGER SVM120-Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln Electric RANGER SVM120-Aのメーカー/サービスへの連絡先に関する情報。

Lincoln Electric RANGER SVM120-Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln Electric RANGER SVM120-Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln Electric RANGER SVM120-Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)