    M ANUAL 1186527 R EV 3 (12/06) $30.00 I NFRARED /R ADIANT C OMPACT B ROILER M ANUAL S ECTION SR Inst allation & Operations Manual Infrared/Radiant Comp act Broiler WARNING Improper installation, adjustment, alteration, service, or maintenance can cause p roperty damage, injury, or death. Read installation, operation, and maintena nce instructio ...

  • Southbend P48-NFR - page 2

    S AFETY P RECAUTIONS I NFRARED /R ADIANT C OMPACT B ROILE R P AGE 2 OF 24 I NSTALLATION & O PERATI ONS M ANUAL 118652 7 R EV 3 (12/06) SAFETY PRECAUTIONS Before installing and operating this equi pment, be sure ever yone involved in its operation is fully trained and aware of precautions. Accidents and problem s c an be caused by failure to fol ...

  • Southbend P48-NFR - page 3

    I NFRARED /R ADIANT C OMPACT B ROILE R I NTRODUCTION I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) P AGE 3 OF 24 I NTRODUCTION Congratulations! You have purcha sed one of the finest pieces of heavy-duty commercial cooking equipment on the market. You will find that your new equipment, like all Southbe nd equipme nt, has been design ...

  • Southbend P48-NFR - page 4

    C LEANING & M AINTENANCE I NFRARED / RADIANT C OMPA CT B ROILER P AGE 4 OF 24 I NSTALLATION & O PERATI ONS M ANUAL 118652 7 R EV 3 (12/06) S PECIFICATIONS NOTICE Local codes regarding in stallation vary greatly from one area to another. The National Fire Protection Association, Inc. states in its NFPA 96 latest edition that local code s are ...

  • Southbend P48-NFR - page 5

    I NFRARED /R ADIANT C OMPACT B ROILE R C LEANING & M AINTENANCE I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) P AGE 5 OF 24 D IMENSIONS Figure 2 ...

  • Southbend P48-NFR - page 6

    C LEANING & M AINTENANCE I NFRARED / RADIANT C OMPA CT B ROILER P AGE 6 OF 24 I NSTALLATION & O PERATI ONS M ANUAL 118652 7 R EV 3 (12/06) V ENTILATION WARNING Improper ventilation can result in perso nal injury or death. Ventilation, which fails to properly remove flue product s, can cause headach es, drowsiness, nausea, or could result in ...

  • Southbend P48-NFR - page 7

    I NFRARED /R ADIANT C OMPACT B ROILE R C LEANING & M AINTENANCE I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) P AGE 7 OF 24 If applicable, the vent line from the gas appliance pressure regulator must be in stalled to the outdo ors in accordance with local codes, or in the absence of local code s, with the National Fuel Gas Code ...

  • Southbend P48-NFR - page 8

    C LEANING & M AINTENANCE I NFRARED / RADIANT C OMPA CT B ROILER P AGE 8 OF 24 I NSTALLATION & O PERATI ONS M ANUAL 118652 7 R EV 3 (12/06) O PERATION DANGER EXPLOSION HAZARD In the event a gas odor is detected, shut down e qui pment at the main shutoff valve. Immediately call the emergency phone number of your ga s supplier. CAUTION If the ...

  • Southbend P48-NFR - page 9

    I NFRARED /R ADIANT C OMPACT B ROILE R C LEANING & M AINTENANCE I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) P AGE 9 OF 24 Figure 3 Broiler Operation Keep the bottom drip pan in place when broi ling. Without it in place, excessive air is pulled past the burners, redu cing te mperature and cookin g efficiency. L IGHTING A FTER ...

  • Southbend P48-NFR - page 10

    C LEANING & M AINTENANCE I NFRARED / RADIANT C OMPA CT B ROILER P AGE 10 OF 24 I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) ...

  • Southbend P48-NFR - page 11

    I NFRARED /R ADIANT C OMPACT B ROILE R C LEANING & M AINTENANCE I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) P AGE 11 OF 24 C LEANING & M AINTENANCE WARNING Shut off the gas supply to the appliance before cle aning or performi ng maintenance on any gas appliance. The appliance may be equipped with a restraint device to lim ...

  • Southbend P48-NFR - page 12

    C LEANING & M AINTENANCE I NFRARED / RADIANT C OMPA CT B ROILER P AGE 12 OF 24 I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) S TAINLESS -S TEEL S URFACES To remove normal dirt, grease and pro duct residue from stai nless steel surfaces that operate at LOW temperature, use ordinary soap and water (with or without deterge nt) ap ...

  • Southbend P48-NFR - page 13

    I NFRARED /R ADIANT C OMPACT B ROILE R I NSTALLATION I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) P AGE 13 OF 24 I NSTALLATION NOTICE These installation procedures mu st be followed by qualified personnel or warranty will be void. Local codes regarding in stallation vary greatly from one area to another. The National Fire Protecti ...

  • Southbend P48-NFR - page 14

    I NSTALLATION I NFRARED /R ADIANT C OMPA CT B ROILER P AGE 14 OF 24 I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) S TEP 2 A : M OUNT ON F LUE R ISER OF R ANGE The Infrared/Radiant Compact Broiler mount s over a range. A special flue riser is shipped with the broiler a nd range. Depending on the shipping requireme nts, the broiler, ...

  • Southbend P48-NFR - page 15

    I NFRARED /R ADIANT C OMPACT B ROILE R I NSTALLATION I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) P AGE 15 OF 24 S TEP 2 B : M OUNT ON W ALL The Infrared/Radiant Compact Broiler is installed by first attaching a mounting bracket to the wall, then attachi ng the broiler to the bracket. 1. Attach the wall-mount assembly to the wall ...

  • Southbend P48-NFR - page 16

    I NSTALLATION I NFRARED /R ADIANT C OMPA CT B ROILER P AGE 16 OF 24 I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) S TEP 2 C : A TTACH C OUNTERTOP L EGS 1. Install each leg by screwing them into the threaded holes in the bottom of the base. 2. Stand the broiler on its legs and position to minim um clearances specified on serial tag. ...

  • Southbend P48-NFR - page 17

    I NFRARED /R ADIANT C OMPACT B ROILE R I NSTALLATION I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) P AGE 17 OF 24 CAUTION ALL PIPE JOINTS AND CONNECTIONS MUST BE T ESTED THOROUGHLY FOR GAS LEAKS. USE ONLY SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHE CK FOR GAS LEAKS. ALL CONNECTIONS MUST BE CHECKED FOR L EAK ...

  • Southbend P48-NFR - page 18

    I NSTALLATION I NFRARED /R ADIANT C OMPA CT B ROILER P AGE 18 OF 24 I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) S TEP 5: C HECK THE I NSTALLATION 1. Check that all screws and bolt s are tightened. 2. Check that gas conne ction has been made correctly. 3. Move the broiler into the final position at which it will be operated. 4. Ch ...

  • Southbend P48-NFR - page 19

    I NFRARED /R ADIANT C OMPACT B ROILE R ...

  • Southbend P48-NFR - page 20

    I NFRARED /R ADIANT C OMPACT B ROILE R P AGE 20 OF ...

  • Southbend P48-NFR - page 21

    I NFRARED /R ADIANT C OMPACT B ROILE R ...

  • Southbend P48-NFR - page 22

    I NFRARED /R ADIANT C OMPACT B ROILE R P AGE 22 OF 24 I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) PARTS LIST PARTS LIST Part Number DESCRIPTION P32-NFR P32-RAD Part Number DESCRIPTION P32-NFR P32-RAD 1164085 Valve ASM, Pilot 1 1 1008752 Orifice Hood, Drill #52 - 4 1188253 Nameplate, Southbend 1 1 1172715 Nameplate, Southbend 1 1 ...

  • Southbend P48-NFR - page 23

    I NFRARED /R ADIANT C OMPACT B ROILE R ...

  • Southbend P48-NFR - page 24

    I NFRARED /R ADIANT C OMPACT B ROILE R P AGE 24 OF 24 I NSTALLATION & O PERATIONS M ANUAL 1186527 R EV 3 (12/06) INFRARED COMPACT BROILER Flue-Riser Mount, Wall Mount, or Countertop A product with the Southb end name incorporates the be st in durability and low maintenance. We all recogni ze, however, that replacement parts and o cca sional pro ...

メーカー Southbend カテゴリー Charcoal Grill

Southbend P48-NFRのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- P48-NFRの取扱説明書
- Southbendの製品カード
- パンフレット
- またはSouthbend P48-NFRの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Southbend P48-NFRの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Southbend P48-NFRの取り付け説明書、サービスマニュアル、簡易説明書、またはSouthbend P48-NFRのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Southbend P48-NFRの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Southbend P48-NFRデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSouthbend P48-NFRを使用するのを助ける技術的文書のことです。説明書は通常、全てのSouthbend P48-NFRユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Southbendの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Southbend P48-NFRの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSouthbend P48-NFRの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Southbend P48-NFRに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Southbend P48-NFRデバイスの基本機能を使うにあたってのヒント。 Southbend P48-NFRのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Southbend P48-NFRに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSouthbend P48-NFRのメーカー/サービスへの連絡先に関する情報。

Southbend P48-NFRについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSouthbend P48-NFRの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSouthbend P48-NFRで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)