    INFRARED VENT -FREE PROP ANE/LP GAS SP ACE H E AT E R ML060HP A ML100HP A ML100TP A TOLL-FREE NUMBER: 1-877-886-5989 W ARNING: Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional info rmatio ...

  • Procom ML100TPA - page 2

    2 IMPORT ANT SAFETY INFORMA TION Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible f or use with other gases. 2. Do not place propane/LP supply tank(s) inside any ...

  • Procom ML100TPA - page 3

    3 PRODUCT IDENTIFICA TION SAFETY DEVICE A standard requirement for all vent-free room heaters. T his heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor. This system requires no matches, ...

  • Procom ML100TPA - page 4

    4 FRESH AIR FOR COMBUSTION AND VENTILA TION PROVIDING ADEQUA TE VENTILA TION The following are excerpts from National Fuel Gas Code. NFP A 54/ANS Z223.1, Section 5.3. Air for Combustion and V entilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T ight Construction 2. Unconfined Space 3. Conf ...

  • Procom ML100TPA - page 5

    5 W ARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. AIR FOR COMBUSTION AND VENTILA TION Continued VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating ...

  • Procom ML100TPA - page 6

    6 VENTILA TION AIR V entilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: Y ou must provide two permanent openings: one within 12 " of the ceiling and one within 12 " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces ...

  • Procom ML100TPA - page 7

    7 INST ALLA TION Figure 4 -Mounting clearances As V iewed From Front of Heater W ARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall. Figure 7 - Mounting Bracket Clearances Figure 6 - Removing Lower Front Panel Of Heater F ASTENING HEA TER TO W ALL Mounting Bracket ...

  • Procom ML100TPA - page 8

    8 INST ALLA TION Figure 10 - Mounting Heater Onto Mounting Bracket Figure 8 - Folding Anchor Figure 9 - Popping Open Anchor Wing For Thin Walls Attaching Mounting Bracket T o W all Note: W all anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to W all Stud Method For attaching mou ...

  • Procom ML100TPA - page 9

    9 INST ALLA TION CONNECTING TO GAS SUPPL Y W ARNING: A qualified service person must connect heater to gas supply. Follow all local codes. W ARNING: This appliance requires a 3/8 " NPT (National Pipe Thread) inlet connection to the pressure regulator. CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an exte ...

  • Procom ML100TPA - page 10

    10 Figure 14 -Equipment Shutoff Valve INST ALLA TION CHECKING GAS CONNECTIONS W ARNING: T est all gas piping and connections for leaks after installing or servicing. Cor- rect all leaks at once. W ARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all lea ...

  • Procom ML100TPA - page 11

    11 Figure 17 - Control Knob In The OFF Position Figure 18 - Pilot OPERA TING YOUR HEA TER Manual Control Models: ML060HP A,ML100HP A  LIGHTING  INSTRUCTIONS 1. STOP! Read the safety information on the side of heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob slightly and turn clockwise to the OFF position. ( see Fi ...

  • Procom ML100TPA - page 12

    12 OPERA TING YOUR HEA TER THERMOST A T MODEL ML100TP A  FOR YOUR SAFETY  READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier t ...

  • Procom ML100TPA - page 13

    13 INSPECTING BURNER Figure 24 - Correct Pilot Flame Pattern Figure 25 - Incorrect Pilot Flame Pattern Figure 27 - Incorrect Burner Flame Pattern Figure 26 - Correct Burner Flame Pattern ODS/PILOT AND BURNER  Use a vacuum cleaner, pres - surized air, or a small, sof t bristled brush to clean. CLEANING BURNER PILOT AIR INLET HOLE We recommend tha ...

  • Procom ML100TPA - page 14

    14 TROUBLESHOOTING Note : All troubleshooting items are listed in order of operation. W ARNING: Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM When ignitor button is pressed and control knob is pressed in and ...

  • Procom ML100TPA - page 15

    15 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s)does not light after ODS/pilot is lit. Delayed ignition of burner(s). Burner backfiring during combustion. Burner plaque(s) does not glow. Slight smoke or odor during initial operation. Heater produces a clicking/ticking noise just after burner is lit or shut off. White powder residue forming w ...

  • Procom ML100TPA - page 16

    16 TROUBLESHOOTING Continued W ARNING: If you smell gas  Shut off gas supply .  Do not try to light any appliance.  Do not touch any electrical switch; do not use any phone in your building.  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.  If you cannot reach your gas supplier, ...

  • Procom ML100TPA - page 17

    17 SPECIFICA TIONS Btu(available) Gas T ype Ignition Pressure Regulator setting Inlet Gas Pressure* (inches of water) Maximum Minimum Dimensions, Inches (HxWxD) Heater Carton Weight (pounds) Heater Shipping ML060HP A 6,000 propane/LP Only Piezo 10 " W.C. 14 " 11 " 19-1/8 × 14-1/8 × 6-3/8 22 × 16-3/4 × 8-1/8 12 15 Note: Dimensions ...

  • Procom ML100TPA - page 18

    18 ILLUSTRA TED P ARTS BREAKDOWN ML060HP A ...

  • Procom ML100TPA - page 19

    19 P ARTS LIST ML060HP A This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual. KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 PA R T NUMBER MB10008 MB09003 ML006-02 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026 ...

  • Procom ML100TPA - page 20

    20 ILLUSTRA TED P ARTS BREAKDOWN ML100HP A ...

  • Procom ML100TPA - page 21

    21 P ARTS LIST ML100HP A This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual. KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PA R T NUMBER MB10008 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML ...

  • Procom ML100TPA - page 22

    22 ILLUSTRA TED P ARTS BREAKDOWN ML100TP A ...

  • Procom ML100TPA - page 23

    23 P ART LIST ML100TP A KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PA R T NUMBER MB10007 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 845-4.8x60Z SIT544-000 ML1 1 1-02 ML056-03 MB40037 MB40039 MB40038 MB40040 ML090-04 MB40041 NRV81FI-10 ML129-02 ML079-01 MB29003 ML060-02 ML083-03 MB2800 ...

メーカー Procom カテゴリー Electric Heater

Procom ML100TPAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ML100TPAの取扱説明書
- Procomの製品カード
- パンフレット
- またはProcom ML100TPAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Procom ML100TPAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Procom ML100TPAの取り付け説明書、サービスマニュアル、簡易説明書、またはProcom ML100TPAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Procom ML100TPAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Procom ML100TPAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがProcom ML100TPAを使用するのを助ける技術的文書のことです。説明書は通常、全てのProcom ML100TPAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Procomの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Procom ML100TPAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははProcom ML100TPAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Procom ML100TPAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Procom ML100TPAデバイスの基本機能を使うにあたってのヒント。 Procom ML100TPAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Procom ML100TPAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるProcom ML100TPAのメーカー/サービスへの連絡先に関する情報。

Procom ML100TPAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもProcom ML100TPAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがProcom ML100TPAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください