Sanyo SPW-FTR124EH56の取扱説明書

32ページ 7.18 mb
ダウンロード

ページに移動 of 32

Summary
  • Sanyo SPW-FTR124EH56 - page 1

    – DC INVERTER Air Conditioner – INST ALLA TION AND OPERA TION MANUAL ■ R410A Models Indoor Units Outdoor Units SPW-FTR124EH56 SPW-FTR164EH56 SPW-FTR184EH56 * Refrigerant R410A is used in the outdoor units. C DC Inverter Main Unit SPW-CR254GVH56-C, SPW -CR364GVH56-C, SPW-CR484GVH56-C Constant Speed (Sub) Unit SPW-CR254GV56-C, SPW -CR364GV56-C, ...

  • Sanyo SPW-FTR124EH56 - page 2

    2 IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operat- ing standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently . For safe installation and trouble-free operation, you must: ● Carefully read this ins ...

  • Sanyo SPW-FTR124EH56 - page 3

    3 2. The standards for minimum room volume are as follows. (1) No partition (shaded portion) (2) When there is an ef fective opening with the adja- cent room for ventilation of leaking refrigerant gas (opening without a door , or an opening 0.15% or larger than the respective floor spaces at the top or bottom of the door). (3) If an indoor unit is ...

  • Sanyo SPW-FTR124EH56 - page 4

    BOL T M8 4 1. GENERAL This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor unit and make sure all accessory parts listed are with the system before beginning. 1-3. T ype of Copper T ube and Insulation Material If you wish to purchase these materials separa ...

  • Sanyo SPW-FTR124EH56 - page 5

    5 2. DIMENSIONS (mm) 86 74 74 74 74 900 86 41 41 190 680 Uni t : m m Center of tubing hole ø 75 (4 places) Wide tube Narrow tube Drain hose ø 26 ...

  • Sanyo SPW-FTR124EH56 - page 6

    6 3. HOW TO INST ALL THE UNIT Fig. 3-1 Minimum operation and maintenance area. (fig. 4-1) Find the place for the installation. The unit can be connec- ted in four different positions: at the right-back side, at the left-back side, at the botton on the right or on the left. (fig. 3- 2) Floor installation. Bend the fullscall diagram, level it and mar ...

  • Sanyo SPW-FTR124EH56 - page 7

    7 20 - 40 mm Drill a 80 mm hole, insert a PVC pipe. (fig. 3-6) Remove the return air grille releasing it from the side guides and the central elastic stop. (fig. 3-7) Open a pre-punched hole for the pipe passage (work from outside).(fig. 3-8) Floor installation. Predispose the fixing of the bracket. Check if the quantity and the rawl plugs type sup ...

  • Sanyo SPW-FTR124EH56 - page 8

    8 Control wiring (C) Inter-unit (between outdoor and indoor units) control wiring (D) Remote control wiring (E) Control wiring for group control 0.75 mm 2 (AWG #18) 0.75 mm 2 (AWG #18) 0.75 mm 2 (AWG #18) Use shielded wiring* Use shielded wiring Use shielded wiring Max. 1,000 m Max. 500 m Max. 500 m (Total) 4. ELECTRICAL WIRING 4-1. General Precaut ...

  • Sanyo SPW-FTR124EH56 - page 9

    9 4-3. Wiring System Diagrams U2 U1 1 2 U2 U1 U2 U1 U2 U1 Group control: 2 1 WHT Remote controller D A E Indoor unit (No. n) Indoor unit (No. 1) Indoor unit (No. 2) Indoor unit (No. 3) C B L N Ground L N L N L N L N BLK 2 1 Power supply 220-240V 50Hz B B B Ground Ground Ground Power supply 200-240V 50Hz Power supply 220-240V 50Hz Power supply 220-2 ...

  • Sanyo SPW-FTR124EH56 - page 10

    10 Outdoor unit Outdoor unit Outdoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit more than 1 m more than 1 m Branch point 16 or fewer Indoor unit Indoor unit Indoor unit Indoor unit less than 1 m Indoor unit Outdoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Outdoor unit Indoor unit NO NO Branc ...

  • Sanyo SPW-FTR124EH56 - page 11

    11 Fig. 4-4 Shielded wire Ground Ground Fig. 4-5 Stranded wire Ring pressure terminal Strip 10 mm Fig. 4-6 Wire Special washer Screw Ring pressure terminal Terminal plate Screw and Special washer Ring pressure terminal Wire (5) Use shielded wires for inter-unit control wiring (c) and ground the shield on both sides, other- wise misoperation from no ...

  • Sanyo SPW-FTR124EH56 - page 12

    12 5. HOW TO PROCESS TUBING The narrow tubing side is connected by a flare nut, and the wide tubing side is connected by brazing. 5-1. Connecting the Refrigerant T ubing Use of the Flaring Method Many of conventional split system air conditioners employ the flaring method to connect refrigerant tubes which run between indoor and outdoor units. In t ...

  • Sanyo SPW-FTR124EH56 - page 13

    13 Caution Before Connecting T ubes Tightly (1) Apply a sealing cap or water-proof tape to prevent dust or water from entering the tubes before they are used. (2) Be sure to apply refrigerant lubricant to the match- ing surfaces of the flare and union before connect- ing them together . This is effective for reducing gas leaks. (Fig. 5-4) (3) For p ...

  • Sanyo SPW-FTR124EH56 - page 14

    14 Fig. 5-10 Fig. 5-1 1 5-3. Insulating the Refrigerant T ubing T ubing Insulation ● Thermal insulation must be applied to all unit tub- ing, including distribution joint (purchased sepa- rately). * For gas tubing, the insulation material must be heat resistant to 120 ° C or above. For other tubing, it must be heat resistant to 80 ° C or above. ...

  • Sanyo SPW-FTR124EH56 - page 15

    15 Fig. 5-10 Fig. 5-1 1 5-4. T aping the T ubes (1) At this time, the refrigerant tubes (and electrical wiring if local codes permit) should be taped together with armoring tape in 1 bundle. T o pre- vent the condensation from overflowing the drain pan, keep the drain hose separate from the refrigerant tubing. (2) Wrap the armoring tape from the bo ...

  • Sanyo SPW-FTR124EH56 - page 16

    16 No. 1 2 3 4 5 Control unit Receiver unit (do not utilize) Parts Remote control unit Remote control holder AAA alkaline battery Spacer T apping screw 4 × 10 T apping screw 4 × 16 T russ-head Phillips Vinyl clamp No. Q'ty P arts Q'ty 6 7 8 9 2 1 1 1 1 2 4 2 3 L 150 Control unit 6PWHT 6PWHT 2PWHT WHT BLK 1 2 BLU YEL PNK RED GR Y BLK Rem ...

  • Sanyo SPW-FTR124EH56 - page 17

    Care and Cleaning 1. For safety , be sure to turn the air conditioner off and also to disconnect the po wer bef ore c leanin g. 2. Do not pour water on the indoor unit to c lean it. This will damage the internal compon ents and cause an ele ctric shoc k hazar d. Air intake and outlet side (Indoor unit) Clean the air intak e and out let side of the ...

  • Sanyo SPW-FTR124EH56 - page 18

    T roub leshooting If your air conditioner does not w ork properly , first check t he f ollo wing points bef ore reques ting service. If it still does not work properly , contact y our dealer o r a ser vice center . Tips f or Energ y Sa ving T rouble P ossible Cause Remed y Air conditioner does not run at all. 1. P o wer f ailure . 1. After a po wer ...

  • Sanyo SPW-FTR124EH56 - page 19

    Entretien et netto y age 1. P our toute sécur ité, éteignez le c limati seur et débranc hez-le de la prise secteur . 2. Ne verse z pas d’eau sur l’unit é intérieure pour l a netto yer . Cela pourrait abîmer les composants interne s et pro v oquer des déchar ges électriques. L ’arrivée d’ air et la sortie d’air (unité intérieur ...

  • Sanyo SPW-FTR124EH56 - page 20

    Guide de dépannage Si le climatiseur ne f onctionne pas correctemen t, effectuez les véri fications suivantes av ant de fa ire appel à un réparate ur . Si le prob lème persiste, prenez contact a v ec v otre concessionn aire ou av ec un ser vice après-vente . Conseils pour économiser l’énergie P anne Cause possible Remède Le climatiseur n ...

  • Sanyo SPW-FTR124EH56 - page 21

    Pflege und Reinigung 1. Au s Sicherheitsgr ünden darauf ac hten, das Gerät v or dem Reinigen auszuschalten und es auß erdem v om Netz zu trennen . 2. Kein W asser auf di e Inneneinheit schütten, um di ese zu reinigen. Dadur ch wer den die inneren Bauteile besc hädigt, und es besteh t Stromschlaggefahr . Lufteinlass - und -auslassseite (Innenei ...

  • Sanyo SPW-FTR124EH56 - page 22

    F ehlersuch e W enn Ih r Klim agerät ni cht r icht ig funkti onier t, zuerst d ie folgenden P unkte übe r prüfen, bev or ein K unden diensttec hniker angeforder t wi rd. Läß t sich d ie Stör ung nicht beh eben, s o wenden Sie sich bi tte an I hren F achhändler od er an eine Kundendiens tstelle. Nützliche Hinw eise für Energieeinsparung St? ...

  • Sanyo SPW-FTR124EH56 - page 23

    Cur a e man utenzione 1. Pe r motivi di sicurezza, accertare che il condizi onatore d’aria sia spento e che la spin a del cav o di alimenta zione sia stac cata dalla presa di corrente prima di pr oceder e con le operazioni di pulizi a. 2. Non versare acqua s ull’unità interna per pulirla. Ciò pu ò danneggiare i componenti interni e c ausare ...

  • Sanyo SPW-FTR124EH56 - page 24

    Pr ima di chiamare il tecnico Se il condizionatore d’aria non funziona corretta mente, prima di chiamare il tecnico per la ripar azione controllare quanto segue . Se ciò non consente di eliminare il prob lema, riv olgersi al proprio rivendit ore o centro di assistenza. Sugger imenti per r ispar miare energia Prob lema Causa probabile Rimedio Il ...

  • Sanyo SPW-FTR124EH56 - page 25

    Cuidados e limpeza 1. P or motiv os de segurança desligue o a parelho de ar condicion ado e desligue-o também da rede antes de procede r à sua limpeza. 2. Não verta água sobre a unidade interior para a limpar . Poder á danificar os componentes inte rnos e causar descar gas eléctricas . Lado de entrada e saída de ar (unidade interior) Limpe ...

  • Sanyo SPW-FTR124EH56 - page 26

    Resolução de prob lemas Se o seu aparelho de ar condicionad o não funciona co rrecta me nte, v erifique primeiro os se guintes pontos ante s de solicitar assistência . Se não conseguir solucionar o p r ob lema, contact e o seu concessionário ou o ser viço de assistência. Sugestões para poupar energia A v aria Causa possível Solução O ap ...

  • Sanyo SPW-FTR124EH56 - page 27

    Φροντίδα κα ι κα θ ά ρι σ µ α 1. Γι α λόγ ου ς ασφαλείας , πριν από το κα θ ά ρ ι σ µ α , πρέπει να σβήνετε τη συσκευή κλι µ ατισ µ ού κα ι βγάζετε το ηλεκτρικ ό κα λώ δ ι ο από την πρίζ α . 2. Μη ρίχνετε νερ ...

  • Sanyo SPW-FTR124EH56 - page 28

    Αν τ ι µ ετώ πιση προβλη µ άτ ων Αν το κλι µ ατιστικό σας δεν λειτουργεί σωστ ά , ελέγξτε πρώτ α τα ακό λ ουθα ση µ εία πριν ζ ητήσετε κάποια εργασία επισκευής . Αν η συσκευή συνεχίζε ι να µ η λειτου ...

  • Sanyo SPW-FTR124EH56 - page 29

    Cuidados y limpieza 1. P or motiv os de segu ridad, asegúrese de apagar el aco ndicionador de aire, y desconectar lo también de la red el éctrica antes de re alizar su limpieza. 2. No vierta agua sobre la unid ad inte rior para limpiarla. El a gua podría estro pear los componentes interno s y produc ir una descar ga eléctrica. Lados de entrad ...

  • Sanyo SPW-FTR124EH56 - page 30

    Localización de a v erías Si su acondicionador de aire no funciona correctamente , compruebe primero la lista de abajo antes de llama r al ser vicio de repar aciones. Si no puede solucionar el prob lema, póngase en contacto con su concesionario o centro de reparacion es. Sugerencias para ahorr a r energía A vería Causa posible Remedio El acond ...

  • Sanyo SPW-FTR124EH56 - page 31

    07_SPW-XDR94GXH56_ES.fm Page 267 T hursday, January 22, 2004 8:30 PM ...

  • Sanyo SPW-FTR124EH56 - page 32

    07_SPW-XDR94GXH56_ES.fm Page 267 T hursday, January 22, 2004 8:30 PM ...

メーカー Sanyo カテゴリー Air Conditioner

Sanyo SPW-FTR124EH56のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SPW-FTR124EH56の取扱説明書
- Sanyoの製品カード
- パンフレット
- またはSanyo SPW-FTR124EH56の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sanyo SPW-FTR124EH56の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sanyo SPW-FTR124EH56の取り付け説明書、サービスマニュアル、簡易説明書、またはSanyo SPW-FTR124EH56のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sanyo SPW-FTR124EH56の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sanyo SPW-FTR124EH56デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSanyo SPW-FTR124EH56を使用するのを助ける技術的文書のことです。説明書は通常、全てのSanyo SPW-FTR124EH56ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sanyoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sanyo SPW-FTR124EH56の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSanyo SPW-FTR124EH56の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sanyo SPW-FTR124EH56に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sanyo SPW-FTR124EH56デバイスの基本機能を使うにあたってのヒント。 Sanyo SPW-FTR124EH56のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sanyo SPW-FTR124EH56に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSanyo SPW-FTR124EH56のメーカー/サービスへの連絡先に関する情報。

Sanyo SPW-FTR124EH56についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSanyo SPW-FTR124EH56の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSanyo SPW-FTR124EH56で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)