Summary
  • Carrier 38EYA - page 1

    38EYA 12 SEER Split-System Heat Pump with Puron® Installation and Start-Up Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, elec ...

  • Carrier 38EYA - page 2

    INSTALLATION IMPORTANT: Specifications for this unit in residential new construction market require using the outdoor unit, indoor unit, refrigerant tubing sets, metering device, and filter drier listed in presale literature. There can be no deviation. Consult the Appli- cation Guideline and Service Manual for Residential Split-System Air Condition ...

  • Carrier 38EYA - page 3

    Step 5 — Elevate Unit Accumulation of water and ice in base pan may cause equipment damage. Elevate unit per local climate and code requirements to provide clearance above estimated snowfall level and ensure adequate drainage of unit. Step 6 — Check Indoor Expansion Device For proper unit operation and reliability, units must be installed with ...

  • Carrier 38EYA - page 4

    Do not leave system open to atmosphere any longer than minimum required for installation. POE oil in compressor is extremely susceptible to moisture absorption. Always keep ends of tubing sealed during installation. If ANY refrigerant tubing is buried, provide a 6 in. vertical rise at service valve. Refrigerant tubing lengths up to 36 in. may be bu ...

  • Carrier 38EYA - page 5

    wrench an additional 1/12 turn (15 ft-lb). DO NOT OVER- TIGHTEN. REFRIGERANT TUBING AND FILTER DRIER Installation of filter drier in liquid line is required. Connect vapor tubing to fittings on outdoor unit vapor service valves. Connect liquid tube to filter drier. (See Table 1 and Fig. 8.) Use refrigerant grade tubing. Connect other end of filter ...

  • Carrier 38EYA - page 6

    1. Pump system down to 28 in. of mercury and allow pump to continue operating for an additional 15 minutes. 2. Close service valves and shut off vacuum pump. 3. Connect a nitrogen cylinder and regulator to system and open until system pressure is 2 psig. 4. Close service valve and allow system to stand for 1 hr. During this time, dry nitrogen will ...

  • Carrier 38EYA - page 7

    24 VAC HOT R G W/W1 Y/Y2 O/W2 R W2 W3 E RVS COOLING C B S1 S2 W2 CARRIER PROGRAMMABLE THERMOSTAT MODEL HP FA, FB, FX FAN COIL HEAT PUMP G Y1/W2 L R O INDOOR FAN HEAT STAGE 2 COOL/HEAT STAGE 1 NOT USED 24 VAC COM NOT USED TROUBLE OPTIONAL OUTDOOR SENSOR CONNECTION Y C C * * * IF AVAILABLE * A97561 A97563 24 VAC HOT R G W/W1 Y/Y2 O/W2 R W3 W2 RVS COO ...

  • Carrier 38EYA - page 8

    24 VAC HOT R C W2 Y G R C RVS COOLING C W2 OTHER BRAND HP THERMOSTAT FA, FB, FX FAN COIL HEAT PUMP G O E W2 E W3 R Y 24 VAC COM HEAT STAGE 2 COOL/HEAT STAGE 1 INDOOR FAN EMERGENCY HEAT O * * * IF AVAILABLE * A97577 A97579 24 VAC HOT R C W2 Y G R W3 W2 G RVS COOLING E W2 OTHER BRAND HP THERMOSTAT TWO OUTDOOR THERMOSTATS FA, FB, FX FAN COIL HEAT PUMP ...

  • Carrier 38EYA - page 9

    G R Y/Y2 O/W2 CARRIER DUAL FUEL THERMOSTAT MODEL DF SINGLE-STAGE FURNACE HEAT PUMP G Y W C Y R O W2 Y1/W2 C B L S1 S2 R C FURNACE COMPRESSOR FAN 24 VAC HOT 24 VAC COM N/A RVS HEATING RVS SENSING OUTDOOR SENSOR CONNECTION OUTDOOR TEMPERATURE SENSOR W/W1 See note 7 RVS COOLING A97538 G R Y/Y2 O/W2 CARRIER DUAL FUEL THERMOSTAT MODEL DF TWO-STAGE OR VA ...

  • Carrier 38EYA - page 10

    24 VAC HOT R G W/W1 Y/Y2 O/W2 RVS COOLING C B S1 S2 CARRIER PROGRAMMABLE THERMOSTAT MODEL HP FA, FB, FX FAN COIL WITH SMART HEAT HEAT PUMP Y1/W2 L R C Y G O W2T W3 W2D Y 0 R C O W2 Y INDOOR FAN HEAT STAGE 2 COOL/HEAT STAGE 1 NOT USED 24 VAC COM NOT USED TROUBLE OPTIONAL OUTDOOR SENSOR CONNECTION JW1 A97566 24 VAC HOT R G W/W1 Y/Y2 O/W2 RVS COOLING ...

  • Carrier 38EYA - page 11

    24 VAC HOT R C Y G O RVS COOLING W2 OTHER BRAND HP THERMOSTAT FA, FB, FX FAN COIL WITH SMART HEAT HEAT PUMP E R C Y G O W2T W3 W2D Y 0 R C O W2 Y INDOOR FAN EMERGENCY HEAT COOL/HEAT STAGE 1 24 VAC COM HEAT STAGE 2 JW1 A97581 24 VAC HOT R C Y G O RVS COOLING W2 OTHER BRAND HP THERMOSTAT FA, FB, FX FAN COIL WITH SMART HEAT HEAT PUMP E R C Y G O W2T W ...

  • Carrier 38EYA - page 12

    Back seating service valves are not equipped with Schrader valves. Fully back seat (counter clockwise) valve stem before removing gage port cap. Do not vent refrigerant to atmosphere. Recover during system repair or final unit disposal. Follow these steps to properly start up the system. 1. Fully back seat (open) liquid and vapor service valves. 2. ...

  • Carrier 38EYA - page 13

    • 3 – phase scroll compressors are rotation sensitive. • A flashing LED on phase monitor indicates reverse rotation. (See Fig. 18 and Table 3.) • This will not allow contactor to be energized. • Disconnect power to unit and interchange 2 field wiring leads on unit contactor. SEQUENCE OF OPERATION NOTE: Defrost control board is equipped wi ...

  • Carrier 38EYA - page 14

    Step 14 — Check Charge UNIT CHARGE Factory charge is shown on unit rating plate. To check charge in cooling mode, refer to Cooling Only Procedure. To check charge in heating mode, refer to Heating Check Chart Procedure. COOLING ONLY PROCEDURE NOTE: If superheat or subcooling charging conditions are not favorable, charge must be weighed in accorda ...

  • Carrier 38EYA - page 15

    Step 15 — Final Checks IMPORTANT: Before leaving job, be sure to do the following: 1. Securely fasten all panels and covers. 2. Tighten service valve stem caps to 1/12-turn past finger tight. 3. Leave User ’ s Manual with owner. Explain system operation and periodic maintenance requirements outlined in manual. 4. Fill out Dealer Installation Ch ...

  • Carrier 38EYA - page 16

    PURON ® (R-410A) QUICK REFERENCE GUIDE • Puron ® refrigerant operates at 50-70 percent higher pressures than R-22. Be sure that servicing equipment and replacement components are designed to operate with Puron ® . • Puron ® refrigerant cylinders are rose colored. • Recovery cylinder service pressure rating must be 400 psig. DOT 4BA400 or ...

メーカー Carrier カテゴリー Heat Pump

Carrier 38EYAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 38EYAの取扱説明書
- Carrierの製品カード
- パンフレット
- またはCarrier 38EYAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Carrier 38EYAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Carrier 38EYAの取り付け説明書、サービスマニュアル、簡易説明書、またはCarrier 38EYAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Carrier 38EYAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Carrier 38EYAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCarrier 38EYAを使用するのを助ける技術的文書のことです。説明書は通常、全てのCarrier 38EYAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Carrierの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Carrier 38EYAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCarrier 38EYAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Carrier 38EYAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Carrier 38EYAデバイスの基本機能を使うにあたってのヒント。 Carrier 38EYAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Carrier 38EYAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCarrier 38EYAのメーカー/サービスへの連絡先に関する情報。

Carrier 38EYAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCarrier 38EYAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCarrier 38EYAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)