  • Pelco C1662M-A - page 1

    INST ALLA TION TW3000P Series Passive Multichannel V ideo T ransceivers C1662M-A (1/06) ...

  • Pelco C1662M-A - page 2

    2 C1662M-A (1/06) Important Safety Instructions 1. Read these instruction s. 2. Keep these instruction s. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this ap paratus near water . 6. Clean only with dry cloth. 7. Do not bl ock any venti lation opening s. Install in accordance with the manufactur er’ s instructions. 8. Do not in ...

  • Pelco C1662M-A - page 3

    C1662M-A (1/06) 3 Description The TW3000 Serie s multichannel video tra nsceivers can transmit mu ltiple video signals o ver unshielded twisted pair (UTP ) cable. The rec eivers are passiv e and require no power . The transceivers are a vailable with 8, 16, or 32 chan nels and can be mo unted into an industry standard 19-inch (48.2 6 cm) wide equip ...

  • Pelco C1662M-A - page 4

    4 C1662M-A (1/06) BACK VIEW Figure 1. Back V iew of TW3008P , TW30 16P , TW3032P  Rack Ears: Allow mounting into an industry standard 19-inch wide equipment rack.  Thumbscrews: Allow back panels to be removed.  Panel with Connectors: The TW3008P and TW3016P have one blank panel.  BNC Connectors: The TW3008P , TW3016P , and TW3032P have ...

  • Pelco C1662M-A - page 5

    C1662M-A (1/06) 5 Installation Make sure all parts ar e present for the units. TW3008P 4 Rack mount screws, 10-32 x 0. 750-inch, Phillip s, pan head (U.S.) 4 Rack mount screws, M6 x 1, 20 mm 4 Washers 2 Screw terminal connectors TW3016P 4 Rack mount screws, 10-32 x 0. 750-inch, Phillip s, pan head (U.S.) 4 Rack mount screws, M6 x 1, 20 mm 4 Washers ...

  • Pelco C1662M-A - page 6

    6 C1662M-A (1/06) APPLICATIONS Figures 3 through 6 show how to use the transceiver s in various applications. Always connect + to + and - to - . The TW3032P is used as an example in Figures 3 through 6. T able A shows the distance in feet with Coaxitron or video only when using a particular type of Cat cable. T able B shows the ma ximum allowable w ...

  • Pelco C1662M-A - page 7

    C1662M-A (1/06) 7 Figure 4. Connecting a UTP Camera to a UTP Receiver NOTE: UTP cameras have a 10-pin RJ-45 connec tor . Standard RJ-45 connectors have 8 pins. Figure 5. UTP Camclosure ® to UTP Receiv er 12 3 4 5 6 7 8 91 01 1 1 21 31 4 1 5 16 17 1 8 19 20 21 22 23 24 25 26 27 2 8 29 30 31 32 TW3032P UTP VIDEO MONITOR + - + - 10 PINS (5-/6+) PIN 5 ...

  • Pelco C1662M-A - page 8

    8 C1662M-A (1/06) Figure 6. Coaxitron PTZ Control 12 3 4 5 6 78 9 1 0 1 1 1 2 1 3 1 4 1 5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 TW3032P UTP VIDEO MONITOR S PE C TRA ® C OAXITRON + - + - V C -UTP BOARD ...

  • Pelco C1662M-A - page 9

    C1662M-A (1/06) 9 Service REPLACING A BACK PANEL Y ou can easily replace a blank back panel or a back panel with connectors. Figure 7 shows the removal of a blank panel after the two thumbscrews are loosened. The panels with connectors can be removed the same way . Figure 7. Ba ck Panel Replacement ...

  • Pelco C1662M-A - page 10

    10 C1662M-A (1/06) Specifications ELECTRICAL Power Source No power required Wire T ype Unshielded twist ed pair (24 A WG maximum) Wire Category Cat3 or better Wire Impedance 100 ohms ± 20% Wire Distance 750 feet maximum DC Loop Resistance 52 ohms per 1,000 feet Differential Capac itance 19pF/ft max T ransient Immunity 300 W peak pulse power (8/20 ...

  • Pelco C1662M-A - page 11

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without char ge, any merc ha ndise proved defect ive in material or wo rkmanship for a period of one year a fter the date of shipment. Exception s to this warranty are as noted belo w: • Five years on FR/F T/FS Series fiber opti c products and TW300 0 Series unshielded ...

  • Pelco C1662M-A - page 12

    Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Arab E ...

メーカー Pelco カテゴリー Stereo Receiver

Pelco C1662M-Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- C1662M-Aの取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco C1662M-Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco C1662M-Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco C1662M-Aの取り付け説明書、サービスマニュアル、簡易説明書、またはPelco C1662M-Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco C1662M-Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco C1662M-Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco C1662M-Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco C1662M-Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco C1662M-Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco C1662M-Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco C1662M-Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco C1662M-Aデバイスの基本機能を使うにあたってのヒント。 Pelco C1662M-Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco C1662M-Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco C1662M-Aのメーカー/サービスへの連絡先に関する情報。

Pelco C1662M-Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco C1662M-Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco C1662M-Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)