1 Owner ’ s Assembly And Operating Manual Ultr a Light Plus, Semi Electric Bed Competitor Item # 15560 ...
-
Drive Medical Design 15560 - page 2
2 REV3.1.23.14 1. Remove contents from carton. Assembl y Instr uctions 2. Placebothendsofthesleepsurfaceontheirsideandaligntheangewiththereceptacleasshown. 3. T oattachtheheadandfootspring,pulltheblackknobawayfortheframeandslidethe? ...
-
Drive Medical Design 15560 - page 3
3 Assembl y Instr uctions Cont. 4. Securethesleepsurfacewiththecotterpinasshown. 5. Lockthecotterpinwiththeattachedclasp.Repeatontheoppositeside. ...
-
Drive Medical Design 15560 - page 4
4 REV3.1.23.14 Assembl y Instr uctions Cont. 6. NOTE:Beforeinstallingmotor ,plughandpendantcableintomotorasshown 7. T o install motor , remove locking caps on top of the motor . HAND CONTROL TheCompetitorbedcomeswithahandcontrolthatwill illuminatewhenthebedisplugged ...
-
Drive Medical Design 15560 - page 5
5 Assembl y Instr uctions Cont. T her e ar e tw o methods for the installa tion of the motor Method A The motorisinstalledonthebedframewhentheframeisstanding on its side. Installation instructions can be found on pages 7-8. Method B The motor is installed from underneath the bed frame (horizontaltothe ...
-
Drive Medical Design 15560 - page 6
6 REV3.1.23.14 Assembl y Instr uctions Cont. A2. Align the opening on the head end of the motorwiththeangeontheheadsectionof thebedandinserttheangeintothemotor compartment. Actuator Bar Flange A3. Withthepalmofyourhand,snapthemotor ushtoth ...
-
Drive Medical Design 15560 - page 7
7 A6. Once in place, replace the motor covers to secure the motor . A6. Oncethemotorisattached,laybedatandinstallheadandfootboards.Thereare2height adjustments on the head and foot board. Select the desired positions and hook the frame onto the foot board.Slidelocktowardslego ...
-
Drive Medical Design 15560 - page 8
8 REV3.1.23.14 Assembl y Instr uctions Cont. End Method A Thechartbelowindicatestheheightadjustmentsastheyrelatetothetwoadjustmentoptions. *Rails cannot be used at this height. Deck Height Pins Leg Holes Upper Lower 1- High 1- Medium 1-Low Deck Height (inches) Deck Height Pins Leg Hole Wheels 1 1* ...
-
Drive Medical Design 15560 - page 9
9 End Method A Method B Installation of the motor from underneath the frame B2. Repeat for the other side. Assembl y Instr uctions Cont. Deck Height Pins Leg Holes Upper Lower 1- High 1- Medium 1-Low B1. Attached head a foot board to frame. ...
-
Drive Medical Design 15560 - page 10
10 REV3.1.23.14 Assembl y Instr uctions Cont. B4. Removethecoversfromthemotorandplaceunderthebedandalignedwiththeactuatorunderthehead section. There are labels on the motor that provide direction and placement in relation to the head section. B5. Withbothhands,liftthemoto ...
-
Drive Medical Design 15560 - page 11
11 Assembl y Instr uctions Cont. B6. Once in place, replace the motor covers to secure the motor . End Method B ...
-
Drive Medical Design 15560 - page 12
12 REV3.1.23.14 Assembl y Instr uctions Cont. Oncethedesiredpositionisfound,turnthethumbscrewuntiltight. Adjustotherlegstothesameposition. 12. Adjustmenttwoisonthelegoftheheadandfootboard.T oadjust,loosenthethumbscrewontheleg ...
-
Drive Medical Design 15560 - page 13
13 Assembl y Instr uctions Cont. Thechartbelowindicatestheheightadjustmentsastheyrelatetothetwoadjustmentoptions. *Rails cannot be used at this height. Deck Height (inches) Deck Height Pins Leg Hole Wheels 1 1* Lower Low No 13.125 Upper Low No 14 Lower Low Y es 14. ...
-
Drive Medical Design 15560 - page 14
14 REV3.1.23.14 Assembl y Instr uctions Cont. 14. TheCompetitorbedcomeswithacasteraccessory(soldseparately ,model#15044SET).T oinstallthe casters,insertthestemofthecasterintothelegreceptacleasshown.Itisrecommendedtoinstall1 non-loc ...
-
Drive Medical Design 15560 - page 15
15 15. T oinstallbedrails,lifttheheadsectionandndtherailreceptaclelocatedontheframeofthebedasshown. Assembl y Instr uctions Cont. 16. Pullreceptacleoutwardandreturnheadsectiontotheatposition. 17. Turn the receptacle in order to receive the rail. ...
-
Drive Medical Design 15560 - page 16
16 REV3.1.23.14 Assembl y Instr uctions Cont. 18. Insert the bed rail into the receptacle. Repeat for the other rail. NOTE: The competitor bed can be used with a free standing trapeze or a Drive Medical frame mounted trapeze (Item # 15560TRAPEZE). A trapeze cannot be mounted on the Competitor head board. ...
-
Drive Medical Design 15560 - page 17
17 Driverecommendsthefollowingmaintenanceandcleaningproceduresbeconductedbetweenusers. ELECTRONICS • Checkallcontrolstomakesureallfunctionsworkproperly . • Foot control • Head control • Checkallcablesfordamagedorfrayedwires. • Powercord • Pe ...
-
Drive Medical Design 15560 - page 18
18 REV3.1.23.14 99 Seaview Boule v ar d P ort W ashington, NY 11050 Phone: 516-998-4 600 T oll F ree: 8 77 .224 . 09 46 F ax: 516. 998.460 1 ww w .driv emedical. com ...