    SINGLE-PACKAGE ELECTRIC HEATING COOLING UNITS HRVBBLHU HRVBBSVC HRVBBLVU Heat Recovery Ventilators Form No. PDS HRV.71.1 The Heat Recov er y V entilation (HR V) system off ered by Bryant is the finest unit on the market toda y . The HR VB provides efficient and cost-eff ective heat recov er y during the heating season when needed most. As tempera ...

  • Bryant HRVBBSVC - page 2

    —2— Model number nomenc lature HRV BB LHU 1 150 Maximum Capacity (CFM) 150 CFM 200 CFM 250 CFM 330 CFM Electrical Supply: 1 — 115 volts Descriptor: LHU — Large Horizontal Unit SVU — Small Vertical Unit LVU — Large Vertical Unit Brand: Bryant Equipment Type: Heat Recovery Ventilator Climate Map f or Ener gy and Heat Reco ver y V entilato ...

  • Bryant HRVBBSVC - page 3

    —3— Contr ols and accessories par t no. nomenc lature ACCESSORIES K V B CN 01 01 BAU CONTROL DESCRIPTION BAU — Bryant Automatic Control BBS — Bryant Basic Control BST — Bryant Standard Control ACCESSORY DESCRIPTION 6FM — 6 in. Flowmeters (2) 7FM — 7 in. Flowmeters (2) 8FM — 8 in. Flowmeters (2) EXH — Exhaust Hood HOD — Intake Ho ...

  • Bryant HRVBBSVC - page 4

    —4— CONTROL F EATURES Basic Control: Allows the user to man ually set f an speed to low or high as required to maximiz e comf or t. Standard Contr ol: Off ers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Setting the w all control to low will activ ate the continuous mode. A utomatic Control: ...

  • Bryant HRVBBSVC - page 5

    —5— DIMENSIONS MODEL NO . ABCDE FG in. mm in. mm in. mm in. mm in. mm in. mm in. mm HR VBBLHU1150 15-1/8 384.2 4-1/16 104 5/58 143.3 14-1/2 368.9 10-3/8 288.9 4-3/8 111.3 7-3/4 196.9 HR VBBLHU1250 19 483 5-13/16 147.7 5-1/16 128.1 14-1/2 368.9 11-3/16 283.9 4-3/8 111.3 10-1/16 255.6 A98002 ...

  • Bryant HRVBBSVC - page 6

    —6— 5 3 ⁄ 4 ″ [146.0] D 2 27 ″ [685.8] 22 1 / 16 ″ [560.4] 1 ″ [25.4] 2 PLCS 15 11 ⁄ 16 ″ [398.5] E 3 1 4 1 15 ⁄ 16 ″ [23.8] 3 3 ⁄ 16 ″ [81.0] 4 9 ⁄ 16 ″ [115.9)] F DIA 2 PLCS 19 3 ⁄ 4 ″ [501.7] 5 7 ⁄ 8 ″ DIA [149.2] 2 PLCS WALL CONTROL WIRING 3 ⁄ 8 ″ DIA [9.5] A G DRAINS 11 ⁄ 16 ″ DIA. [17.5] 2 PLCS B ...

  • Bryant HRVBBSVC - page 7

    —7— HR VBBL VU1200 or HR VBBL VU1330 A98001 17 9 ⁄ 16 ″ [446.9] 4 3 ⁄ 4 ″ [120.6] 8 1 ⁄ 8 ″ DIA [206.4] 2 PLCS 5 13 ⁄ 16 ″ [147.6] 5 7 ⁄ 8 ″ DIA [148.2] 2 PLCS 6 15 ⁄ 16 ″ [176.2] 7 1 ⁄ 8 ″ [181.0] 18 5 ⁄ 16 ″ [465.1] 2 3 ⁄ 16 ″ [55.6] 2 PLCS 12 3 ⁄ 4 ″ [323.9] 23 15 ⁄ 16 ″ [608.0] 43 ″ (1092.2) 19 ...

  • Bryant HRVBBSVC - page 8

    —8— PHYSICAL DATA P ERFORMANCE DATA ELECTRICAL DATA MODEL DESCRIPTION CONVENTIONAL COMP A CT HIGH EFFICIENCY Model No. HR VBBVHU1150 HR VBBVHU1260 HR VBBSVC1150 HRVBBSVC1200 HR UBBL VU1150 HR UBBL VU1200 HR UBBL VU1330 P ort Locations Sides Sides T op T op T op T op T op Core T ype P olypropylene Cross Flow P olypropylene Cross Flow P olypropyl ...

  • Bryant HRVBBSVC - page 9

    —9— METHODS TO SIZE HR V’ S METHOD 1 1. Calculate cu ft of occupied space. 2. Multiply by recommended air changes per hr (A C/h). 3. Divide by 60 min utes per hr to conv er t to CFM. EXAMPLE: 2000 sq ft with 8 ft ceiling 0.35 air changes per hr (A C/h) (2000 sq ft x 8 ft ceiling x 0.35 A C/h) / 60 min/h = 93.3 CFM METHOD 2 1. Multiply number ...

  • Bryant HRVBBSVC - page 10

    —1 0— COOLING LOAD BTU The cooling load char t shows loads in Btuh as well. T o use the cooling load char t, first find the design enthalp y from a psychrometric char t using the design dr y bulb and wet b ulb temperatures. (See psychrometric char t on p. 11.) The cooling load can then be f ound f or a range of enthalpies f or each ventilator ...

  • Bryant HRVBBSVC - page 11

    —1 1— .025 .024 .023 .022 .021 .020 .019 .018 .017 .016 .015 .014 .013 .012 .95 .90 .85 .80 .75 .70 .65 .60 .55 .50 .45 .40 .35 .011 .010 .009 .008 .007 .006 .005 .004 .003 .002 .001 0 Sensible heat factor P ounds of moisture per pound of dry air 7 8 9 10 11 12 32 33 34 35 36 37 38 39 40 41 42 43 44 45 47 48 49 46 27 28 29 30 31 19 20 21 22 23 ...

  • Bryant HRVBBSVC - page 12

    —1 2— SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: New FORM PDS HRV.71.1 © 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 12HR-VBO 3-00 HR V INSTALLED WITH FOR CED AIR SYSTEM HR V INSTALLED WITH INDEPE ...

メーカー Bryant カテゴリー Heating System

Bryant HRVBBSVCのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HRVBBSVCの取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant HRVBBSVCの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant HRVBBSVCの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant HRVBBSVCの取り付け説明書、サービスマニュアル、簡易説明書、またはBryant HRVBBSVCのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant HRVBBSVCの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant HRVBBSVCデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant HRVBBSVCを使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant HRVBBSVCユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant HRVBBSVCの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant HRVBBSVCの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant HRVBBSVCに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant HRVBBSVCデバイスの基本機能を使うにあたってのヒント。 Bryant HRVBBSVCのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant HRVBBSVCに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant HRVBBSVCのメーカー/サービスへの連絡先に関する情報。

Bryant HRVBBSVCについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant HRVBBSVCの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant HRVBBSVCで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)