Fujitsu Siemens Computers RX600 S3の取扱説明書

17ページ 0.12 mb
ダウンロード

ページに移動 of 17

Summary
  • Fujitsu Siemens Computers RX600 S3 - page 1

    PRIMERGY RX6 00 S3 incl. SAS version System configurator and order-information guide Contents Instructions Configuration diagram Configurator 0 0 System software 1 I Basic unit 2 II Processor 3 III Memory 4 IV onboard SCSI / SAS Contr 5 V USB devices / optical devices 6 VI Hard disk drives 7 VII Tape Devices 8 VIII optional SCSI / RAID controller 9 ...

  • Fujitsu Siemens Computers RX600 S3 - page 2

    System configurator and order-information guide PRIMERGY RX600 S3 Status 2007-01-24 Instructions This document contains basic product and configuration information that will enable you to configure your system via PC-/System-Architect Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Rack ...

  • Fujitsu Siemens Computers RX600 S3 - page 3

    System configurator and order-information guide PRIMERGY RX600 S3 Status 2007-01-24 Configuration diagram PRIMERGY RX600 S3 TOP View System unit ( I ) Extension slots Memory ( III ) SCSI / RAID controller ( VIII ) Fiber Channel ( IX ) Communication/Network ( X ) 7 6 5 4 Processors must be plugged in order according the picture. 3 Processor ( II ) 2 ...

  • Fujitsu Siemens Computers RX600 S3 - page 4

    PRIMERGY-Software Configurators and Release Lists Start "PRIMERGY RX600 S3" PRIMERGY RX600 S3 Status 2007-01-24 SW - Configurator 32 bit with OEM-Software without OEM-Software for PRIMERGY Server Usage of OEM SW from MS is for PRIMERGY Server not possible under VMware OEM-SW is bound to HW and VMware-Software is not allowed to be ordered ...

  • Fujitsu Siemens Computers RX600 S3 - page 5

    PRIMERGY-Software Configurators and Release Lists Start "PRIMERGY RX600 S3" PRIMERGY RX600 S3 Status 2007-01-24 SW Configurator EM64T with OEM-Software without OEM-Software for PRIMERGY Server Usage of OEM SW from MS is for PRIMERGY Server not possible under VMware OEM-SW is bound to HW and VMware-Software is not allowed to be ordered - V ...

  • Fujitsu Siemens Computers RX600 S3 - page 6

    System configurator and order-information guide Start PRIMERGY RX600 S3 PRIMERGY RX600 S3 Status 2007-01-24 Section I Basic unit PRIMERGY RX600 S3 SCSI PRIMERGY RX600 S3 SAS Rack unit 4U Rack unit 4U SCSI basic unit with: SAS basic unit with: Basic Unit including: - 2 hot-plug power supply (redundant) - 3 + 2 bays for 1" HDD`s (two channels) - ...

  • Fujitsu Siemens Computers RX600 S3 - page 7

    System configurator and order-information guide A PRIMERGY RX600 S3 Status 2007-01-24 Section II Processor A 4-way processor system requires a multi-processor operating system Later upgrading to a four-way-processor system is also possible VRM´s for 1st/2nd CPU are on the Motherboard, for the 3nd / 4th CPU addition VRM Modules are required. Extens ...

  • Fujitsu Siemens Computers RX600 S3 - page 8

    System configurator and order-information guide B PRIMERGY RX600 S3 Status 2007-01-24 Section III Memory The system can be equipped with up 4 memory boards with 2 memory banks each. One Memory Board is allready supplied in the base unit. Each memory board can be equipped with up to 2x 8GB = 16GB memory. The maximal extension is 64GB with 4GB module ...

  • Fujitsu Siemens Computers RX600 S3 - page 9

    System configurator and order-information guide C PRIMERGY RX600 S3 SAS Status 2006-12-31 Section IV on-board SCSI / SAS Controller SCSI Base Units The system is equipped with a two channel Utra 320 onboard SCSI controller including a full featured RAID controller with 256MB Cache (suporting the RAID level 0, 1, 5, 10, 50). As option the on-board R ...

  • Fujitsu Siemens Computers RX600 S3 - page 10

    System configurator and order-information guide D PRIMERGY RX600 S3 Status 2007-01-24 SAS Base Units AB. on-board SCSI-/ SAS RAID-Controller for accessible drives and SAS HDD´s -> SAS Version The system will be delivered with a 8-port SAS RAID controller for the connection of SAS HDD´s This SAS RAID Controller is equipped with 256MB Cache and ...

  • Fujitsu Siemens Computers RX600 S3 - page 11

    System configurator and order-information guide E PRIMERGY RX600 S3 Status 2007-01-24 Section V USB devices / optical devices One of the following USB devices must be used for integrating the drivers during installation process if no automized (e.g. Serverstart / Altiris / RIS / ADS / …) installation is done: 1) USB DVD+-RW: S26391-F3152-L300 Tra ...

  • Fujitsu Siemens Computers RX600 S3 - page 12

    System configurator and order-information guide F PRIMERGY RX600 S3 Status 2007-01-24 Section VII Tapes devices S26361-F3128-E101 internal SCSI-Cable for connetion of internal Tape devices max. 1x per system S26361-F2848-E3 S26361-F2849-E3 S26361-F3224-E3 Tape drive DDS Gen5 Tape drive VXA-2 Tape drive VXA-320 S26361-F2848-E31 (only for OBDR) 80GB, ...

  • Fujitsu Siemens Computers RX600 S3 - page 13

    System configurator and order-information guide G PRIMERGY RX600 S3 Status 2007-01-24 Section VIII optional SCSI / RAID controller B. SCSI - controller for internal and external devices. S26361-F2399-E1 1-channel SCSI U160 Controller Adaptec 29160 plug: internal: HD 50-pin & HD68 max. 2x external: HD68 without cable 64/66 PCI 3.3V and 5V tolera ...

  • Fujitsu Siemens Computers RX600 S3 - page 14

    System configurator and order-information guide H PRIMERGY RX600 S3 Status 2007-01-24 Section IX Fibre channel controller Qlogic controller Emulex Controller No mix and match for Qlogic and S26361-F3097-E1 Emulex Fibre channel controllers 2GBit/s FC Controller possible Qlogic QLA2340, full height bracket 1 channel 2GBit/sec FC Controller LC Interfa ...

  • Fujitsu Siemens Computers RX600 S3 - page 15

    System configurator and order-information guide I PRIMERGY RX600 S3 Status 2007-01-24 Section X Communication / Network on-board LAN Controller Teaming: Failover, Load Balancing Dual Gbit Ethernet Contr. on-board The Intel LAN Controllers Pro 1000MT, 1000MF, 1000PT, 1000PF BroadCom BCM5704 can be used with the on-board controller in Teaming Mode Wi ...

  • Fujitsu Siemens Computers RX600 S3 - page 16

    System configurator and order-information guide J PRIMERGY RX600 S3 Status 2007-01-24 Section XI System Management Products (RemoteView) S26361-F1790-E221 S26361-F2425-E103 RemoteView Software V5.0 RSB S2 LP 3HU Installation and configuration of RemoteView Service Board S2 RemoteView Web and LAN FrontEnd Low Profile Version with 3 U bracket RSB, BM ...

  • Fujitsu Siemens Computers RX600 S3 - page 17

    System configurator and order-information guide PRIMERGY RX600 S3 Status 2007-01-24 Change Report Date Order number Changes 2007-01-24 S26361-F3124-E200 VRM module for 3rd/4th CPU - no longer available 2007-01-24 S26361-F3124-E361 Processor Xeon MP 3.66GHz 1MB - no longer available 2007-01-24 S26361-K988-V122 Rack mountable server 19" (4U) wit ...

メーカー Fujitsu Siemens Computers カテゴリー Switch

Fujitsu Siemens Computers RX600 S3のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RX600 S3の取扱説明書
- Fujitsu Siemens Computersの製品カード
- パンフレット
- またはFujitsu Siemens Computers RX600 S3の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Fujitsu Siemens Computers RX600 S3の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Fujitsu Siemens Computers RX600 S3の取り付け説明書、サービスマニュアル、簡易説明書、またはFujitsu Siemens Computers RX600 S3のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Fujitsu Siemens Computers RX600 S3の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Fujitsu Siemens Computers RX600 S3デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFujitsu Siemens Computers RX600 S3を使用するのを助ける技術的文書のことです。説明書は通常、全てのFujitsu Siemens Computers RX600 S3ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Fujitsu Siemens Computersの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Fujitsu Siemens Computers RX600 S3の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFujitsu Siemens Computers RX600 S3の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Fujitsu Siemens Computers RX600 S3に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Fujitsu Siemens Computers RX600 S3デバイスの基本機能を使うにあたってのヒント。 Fujitsu Siemens Computers RX600 S3のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Fujitsu Siemens Computers RX600 S3に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFujitsu Siemens Computers RX600 S3のメーカー/サービスへの連絡先に関する情報。

Fujitsu Siemens Computers RX600 S3についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFujitsu Siemens Computers RX600 S3の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFujitsu Siemens Computers RX600 S3で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)