PYLE Audio C6110の取扱説明書

22ページ 1.4 mb
ダウンロード

ページに移動 of 22

Summary
  • PYLE Audio C6110 - page 1

    Single-Stage Oilfr ee Compr essor Instruction manual The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for future reference. Model No. ______________________________________ T ype ___________________________________________ Serial No. ______________________________________ ...

  • PYLE Audio C6110 - page 2

    2- ENG A10244 SAFETY GUIDELINES - DEFINITIONS Indicates an imminent- ly hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor ...

  • PYLE Audio C6110 - page 3

    3- ENG A10244 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this pr oduct could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire How T o Prevent It What Could Happen It is norm ...

  • PYLE Audio C6110 - page 4

    4- ENG A10244 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin an ...

  • PYLE Audio C6110 - page 5

    5- ENG A10244 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr ...

  • PYLE Audio C6110 - page 6

    6- ENG A10244 WARNING: Risk of Burns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance ...

  • PYLE Audio C6110 - page 7

    7- ENG A10244 Review and underst and all instruction s and warnings in this manual. Become famil iar with the operation and contr ols of the air compr essor . Keep operati ng area clear of all persons, pets, and obstacle s. Keep childr en away from the air compr essor at all times . Do not operate the produc t when fatigue d or under the influence ...

  • PYLE Audio C6110 - page 8

    8- ENG A10244 GLOSSAR Y DUTY CYCLE This air compressor pump is capable of running continuously . However , to prolong the life of your air compressor , it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour . Become familiar with these terms before ...

  • PYLE Audio C6110 - page 9

    9- ENG A10244 GROUNDING INSTRUCTIONS Risk of Electrical Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see f ...

  • PYLE Audio C6110 - page 10

    10- ENG A10244 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as neede ...

  • PYLE Audio C6110 - page 11

    11- ENG A10244 Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : T ur n this switch "On/Auto" to provide automatic power to the pressur e switch and "Off" to remove power at the end of each use. Pressur e Switch: The pressure switch automatically starts the motor when th ...

  • PYLE Audio C6110 - page 12

    12- ENG A10244 Air Compressor Pump (not shown): Compresses air into the air tank. W orking air is not available until the compressor has raised the air tank pressur e above that requir ed at the air outlet. Check V alve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When th ...

  • PYLE Audio C6110 - page 13

    13- ENG A10244 How to Start: 1. T urn the On/Auto/Off lever to "On/Auto" and allow tank pressur e to build. Motor will stop when tank pressur e reaches "cut-out" pressure. 2. Pull the regulator knob out and tur n clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ...

  • PYLE Audio C6110 - page 14

    14- ENG A10244 NOTE: See "Operation" section for the location of controls. T o Drain T ank 1. Set the On/Auto/Off lever to "Off" and unplug unit. 2. Pull the regulator knob out and tur n counterclockwise to set the outlet pressur e to zero. 3. Remove the air tool or accessory . 4. Pull ring on safety valve allowing air to bleed ...

  • PYLE Audio C6110 - page 15

    15- ENG A10244 SERVICE AND ADJUSTMENTS T o Replace or Clean Check V alve 1. Release all air pressur e from air tank. See "T o Drain T ank" in the "Maintenance" section. 2. Set the On/Auto/Off lever to "Off" and unplug unit. 3. Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet ...

  • PYLE Audio C6110 - page 16

    16- ENG A10244 T o Replace Regulator 1. Release all air pressur e from air tank. See "T o Drain T ank" in the "Maintenance" section. 2. Set the On/Auto/Off lever to "Off" and unplug unit. 3. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator . 4. Using an adjustable wrench ...

  • PYLE Audio C6110 - page 17

    17- ENG A10244 STORAGE Before you store the air compressor , make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to "Off" and unplug unit. 3. T ur n the regulator counterclockwise and set the outlet pressure to ze ...

  • PYLE Audio C6110 - page 18

    18- ENG A10244 TROUBLESHOOTING Risk of Unsafe Operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air , or moving parts. Personal injuries can occur . Before performing any maintenance or repair , disconnect power source from the compressor and bleed off all air press ...

  • PYLE Audio C6110 - page 19

    19- ENG A10244 PROBLEM CAUSE CORRECTION It is normal for "some" pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation" section. NOTE: Adjust the regulated press ...

  • PYLE Audio C6110 - page 20

    20- ENG A10244 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit breaker tripped. 1. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular bran ...

  • PYLE Audio C6110 - page 21

    21- ENG A10244 NOTES ...

  • PYLE Audio C6110 - page 22

    22- ENG A10244 LIMITED W ARRANTY PORTER-CABLE CORPORA TION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty per ...

メーカー PYLE Audio カテゴリー Air Compressor

PYLE Audio C6110のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- C6110の取扱説明書
- PYLE Audioの製品カード
- パンフレット
- またはPYLE Audio C6110の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、PYLE Audio C6110の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、PYLE Audio C6110の取り付け説明書、サービスマニュアル、簡易説明書、またはPYLE Audio C6110のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、PYLE Audio C6110の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

PYLE Audio C6110デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPYLE Audio C6110を使用するのを助ける技術的文書のことです。説明書は通常、全てのPYLE Audio C6110ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

PYLE Audioの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. PYLE Audio C6110の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPYLE Audio C6110の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。PYLE Audio C6110に関してこのドキュメントで見つけることができる全てのヒントの目次
3. PYLE Audio C6110デバイスの基本機能を使うにあたってのヒント。 PYLE Audio C6110のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。PYLE Audio C6110に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPYLE Audio C6110のメーカー/サービスへの連絡先に関する情報。

PYLE Audio C6110についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPYLE Audio C6110の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPYLE Audio C6110で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)