  • Linear AE-100 - page 1

    USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free FAX (800) 468-1340 www .linearcorp.com AE-100 Commercial T elephone Entr y System PRINTER’S INSTRUCTIONS: INSTR,INSTL,AE-100 - LINEAR P/N: 225787 C - INK: BLACK - MA TERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: S ...

  • Linear AE-100 - page 2

    2 Contents Introduction The Model AE-100 Commercial T elephone Entry System is designed for use as an access control de vice for small apar tments or gated communities with up to 125 residents. The system can be used in a lobby or outside . Surf ace, recessed, and pedestal mounting options are suppor ted. The system utilizes hands-free, full duple ...

  • Linear AE-100 - page 3

    3 F eatur e Over view Installer Friendly Programming T o make it easy f or installers familiar with Linear’ s and other manuf acturer’ s access control systems, two methods of progr amming are av ailable. Step numbers or function codes that match other equipment help the installer to make quic k programming changes with ke ystrokes they ha ve u ...

  • Linear AE-100 - page 4

    4 Component Locations LCD DI S PLAY CA B INET LOCK PO S TAL LOCK (OPTIONAL) S PEAKE R KEYPAD LI G HTIN G MIC R OPHONE EA R TH GR OUND S TUD POWE R TE R MINAL S ACCE SS R ELAY TE R MINAL S TELEPHONE TE R MINAL S TELEPHONE JACK PO S TAL S WITCH CONNECTO R DIA G NO S TIC INDICATO RS MAIN POWE R S WITCH MIC R OPHONE PO S TAL LOCK (OPTIONAL) S PEAKE R M ...

  • Linear AE-100 - page 5

    5 Wiring Diagram EA R TH GR OUND B ACKUP B ATTE R Y TTY JACK S PEAKE R VIDEO OUT PO S TAL LOCK ACCE SS R ELAY 16 VAC INPUT N.O. COM N.C. DI G ITAL S PEECH VOLUME S PEAKE R PHONE VOLUME MAIN POWE R S WITCH S Y S TE M R E S TA R T B UTTON DI S PLAY CONT R A S T CAME R A CONNECTO R TELEPHONE JACK TELEPHONE TE R MINAL S POWE R PHONE S TATU SR ELAY B AT ...

  • Linear AE-100 - page 6

    6 Impor tant Mounting Requir ements The AE-100 T elephone Entr y System can be installed f or public or priv ate use. The mounting requirements will vary depending on the installation. Revie w the follo wing information before beginning the installation. Mounting Environment Consider the environmental f actors at the desired mounting location. The ...

  • Linear AE-100 - page 7

    7 Entr y Sys tem Mounting The AE-100 cabinet is designed to be mounted three wa ys: The unit can be mounted directly to a wall or fl at surf ace. • The unit can be mounted recessed into a wall. • The unit can be mounted on a standard goose-neck pedestal. • Choose a well lit location near the controlled opening. Wiring access f or power , tel ...

  • Linear AE-100 - page 8

    8 Entr y Sys tem Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessory tr im-ring Model TR-100 (P/N A CP00941). The trim-r ing mounts in the w all and the cabinet attaches to the trim-ring. 1. Identify the location of any studs in the wall. ✦ CA UTION!: W atch out for wiring inside the wall. 2. Determine a ...

  • Linear AE-100 - page 9

    9 Access Rela y Wiring The access relay controls access de vices, such as a door strike, magnetic lock, automatic door , barr ier gates , or automatic sliding gate. The RELA Y indicator displays the status of the rela y . Door or Pedestrian Gate Control 1. Install a low v oltage electric door str ik e or magnetic lock as a locking de vice for the d ...

  • Linear AE-100 - page 10

    10 Multiple Unit T elephone Wiring Up to four AE-100 units ma y be connected to the same dedicated telephone line to form a simple network. Connecting multiple units allo ws transf erring programming data (either the director y entries only or the entire memory’s contents) from the “master” unit to the other sub-units. ✦ NO TE: F or a multi ...

  • Linear AE-100 - page 11

    11 P ower, Bat ter y, & Gr ound Wiring Power Wiring ✦ NO TE: DO NO T APPL Y PO WE R UNTIL THE IN S T ALLA TION I S COMPLETE. TU R N MAIN PO WE R S WITCH OFF BEFO R E WI R IN G . 1. Route two wires between the AE-100 and the po wer transformer . For po wer wire runs up to 100 feet, use 18 A WG, THHN 600-v olt • insulated wire. For po wer wir ...

  • Linear AE-100 - page 12

    12 Optional P os tal Lock A postal lock can be installed in the AE-100 Entry System to provide ke yed access f or the postal ser vice . The AE-100 case is designed to accept a U .S. Postal Service postal lock. When the postal loc k is engaged the access relay will activ ate. Postal Lock Installation 1. Remov e the four loc knuts that retain the pos ...

  • Linear AE-100 - page 13

    13 P r ogramming Refer ence & F actor y Defaults ST AND ARD PRO G RAMMIN G POSITION NUM B ER AL TERNA TE FUNCTION CODE NUM B ER FUNCTION OF PRO G RAMMIN G STEP F A CTOR Y DEF A UL T V ALUE 99 91 EXIT PROGRAM MODE SYSTEM OPTIONS 01 00 CHANGE MASTER P ASSWORD 12 3 456 02 06 DIRECT OR Y CODE LENGTH 3 07 07 SET SUB-UNIT NUMBERS NO T SET 3 8 3 8 SYS ...

  • Linear AE-100 - page 14

    14 Access to P r ogramming T o make it easy f or installers familiar with Linear’ s and other manufacturer’ s access control systems, two methods of progr amming are av ailable. Programming P osition Numbers (or Function Codes) that match other equipment help the installer to make quic k programming changes with ke ystrokes they’v e used bef ...

  • Linear AE-100 - page 15

    15 P r ogramming Over the T elephone Most system commands can be programmed using a T ouchT one™ telephone. The telephone’ s keypad will act similar to the AE-100’ s keypad. Both programming methods can be used ov er the telephone. Connecting with a T elephone 1. Place a call to the telephone number of the line that the AE-100 is connected to ...

  • Linear AE-100 - page 16

    16 Multi-unit Ins tallations Up to four AE-100 units ma y be connected to the same dedicated telephone line to form a simple network. Connecting multiple units allo ws transf erring programming data (either the director y entries only or the entire memory’s contents) from the “master” unit to the other sub-units using the system utility comma ...

  • Linear AE-100 - page 17

    17 Resident Data P r ogramming Up to 125 resident Names and T elephone Numbers can be set. Each resident entry is assigned a Director y Code . The Director y Code is the number visitors enter to hav e the system call the resident. Visitors can also contact a resident display ed by pressing the key . Use the programming w orksheet supplied to organi ...

  • Linear AE-100 - page 18

    18 PPN 33 33#CODE#CODE# CODE = THE STAND-ALONE ENTRY CODE TO DELETE CODE = THE STAND-ALONE ENTRY CODE AGAIN FOR VERIFICATION DELETING A STAND-ALONE ENTRY CODE PPN 31 31#CODE#CODE# CODE = NEW STAND-ALONE ENTRY CODE CODE = NEW STAND-ALONE ENTRY CODE AGAIN FOR VERIFICATION ADDING A STAND-ALONE ENTRY CODE PPN 38 38#LANG# LANG = SYSTEM DISPLAY LANGUAGE ...

  • Linear AE-100 - page 19

    19 PPN 51 51#COUNT# COUNT = NUMBER (1-9) OF INCORRECT ENTRIES THAT WILL CAUSE A 90 SECOND LOCKOUT KEYPAD LOCKOUT COUNT FACTORY SETTING: 3 TRIES PPN 57 57#LINE 1#LINE 2# LINE 1 = UP TO 16 CHARACTERS TEXT LINE 2 = UP TO 16 CHARACTERS TEXT WELCOME DISPLAY TEXT FACTORY SETTING: LINEAR ACCESS TELEPHONE ENTRY PPN 61 61#ANSWER# ANSWER = 0 FOR AUTO ANSWER ...

  • Linear AE-100 - page 20

    20 PPN 64 64#TIME# TIME = TIME UNTIL AUTO-DISCONNECT (010-180 SECONDS) MAXIMUM VISITOR TALK TIME FACTORY SETTING: 60 SECONDS PPN 63 63#TONE# TONE = 0 FOR ACCESS RELAY TONE OFF TONE = 1 FOR ACCESS RELAY TONE ON SPEAKER TONE ON ACCESS RELAY ACTIVATION FACTORY SETTING: RELAY TONE ON PPN 77 77#CONTROL# CONTROL = 0 TO DISABLE RESIDENT CONTROL CONTROL = ...

  • Linear AE-100 - page 21

    21 PPN 30 30#SUB-UNITS#5# SUB-UNITS = EACH SUB-UNIT NUMBER (2-4) TO COPY ACCESS DATA TO IN A MULTI-UNIT INSTALLATION COPY ACCESS DATA ONLY FROM MASTER TO SUB-UNITS PPN 34 34#SUB-UNITS#5# SUB-UNITS = EACH SUB-UNIT NUMBER (2-4) TO COPY ALL DATA TO IN A MULTI-UNIT INSTALLATION COPY ALL DATA FROM MASTER TO SUB-UNITS PPN 35 35#MESSAGE#CLEAR# MESSAGE = E ...

  • Linear AE-100 - page 22

    22 PPN 92 92#92# DELETE ALL DIRECTORY ENTRIES PPN 200 200#000000#000000# TOTAL MEMORY RESET PPN 37 37#POLL RESULT POLL RESULT = DISPLAY OF SUB-UNIT NUMBERS THAT RESPONDED WITH NO ERRORS ON THE FIRST TRY POLL SUB-UNITS PPN 83 83# RELEASE ACCESS RELAY PPN 73 73#INFO INFO = DISPLAY OF SYSTEM FIRMWARE VERSION DISPLAY SYSTEM INFORMATION PPN 80 80#HOURS# ...

  • Linear AE-100 - page 23

    23 A UDIO PROMPTS FOR EA CH PRO G RAMMIN G METHOD CONDITION AL TERNA TE METHOD SOUND ST AND ARD METHOD SOUND AFTER AN INCORRECT ENTR Y TWO LONG BEEPS ONE LONG BEEP AFTER A CORRECT ENTR Y OF AN INTERIM STEP ONE SHORT BEEP TWO SHORT BEEPS AFTER A COMPLETE COMMAND HAS BEEN ENTERED CORRECTL Y TWO SHORT BEEPS THREE SHORT BEEPS EXITING PROGRAMMING MODE T ...

  • Linear AE-100 - page 24

    24 MASTER CODE: ENTER DIR: ENTER NAME: Dir # is used! ERROR DATA TELEPHONE #: ACCESS CODE: ALTERNATE PROGRAMMING METHOD Alternate P r ogramming Refer ence Refer to the follo wing pages when programming using the Alternate Programming method. For each of the f ollowing steps, enter the Master P assword and enter Programming Mode (if the unit is not ...

  • Linear AE-100 - page 25

    25 MODIFY DIR: ENTER THE NAME: (CURRENT NAME) ACCESS CODE: (current CODE) Phone number (current PH#) DELETE DIR: (DIR CODE) IS DELETEd ! ERROR ON DELETE DELETE ALL? 1 3 ARE YOU SURe? 5 ALTERNATE PROGRAMMING METHOD FUNCTION CODE LOCAL PRO G RAMMIN G TELEPHONE PR O G RAMMIN G 02 MODIFY AN EXISTING TENANT DIRECT OR Y ENTR Y Choose a tenant’ s Direct ...

  • Linear AE-100 - page 26

    26 OPEN:00 HOURS DIR DIGITS: 3 # SUB-UNITS(2-4) SYSTEM # (1 -4) 1 ALTERNATE PROGRAMMING METHOD NO TE: AFTER SETTIN G UP A MUL TI-UNIT INST ALLA TION WITH FUNCTIONS 07 & 08, WRITE IN THE UNIT LOCA TIONS B ELOW AND ON P A G E 6 IN THE F A CILITY MANA G ER’S G UIDE TO INDICA TE TO THE F A CILITY MANA G ER THE UNIT NUM B ERS ASSI G NED AND THEIR ...

  • Linear AE-100 - page 27

    27 (BLANK DISPLAY) UNITS: ARE YOU SURE ? 5 ACCESS CODE: ACCESS CODE: ACCESS CODE: ACCESS CODE: ALTERNATE PROGRAMMING METHOD FUNCTION CODE LOCAL PRO G RAMMIN G TELEPHONE PR O G RAMMIN G 10 WELCOME DISPLA Y TEXT The AE-100 display will sho w a visitor a welcome message alternating with instr uctions on how to fi nd and call a resident. The welcome m ...

  • Linear AE-100 - page 28

    28 UNITS: ARE YOU SURE ? 5 (ERROR MESSAGE) Low Battery NO AC COMMUNICATION ERROR UNIT # CLEAR ERROR LOG? YES ENTER 5 UNITS RESPONDING LANGUAGE: 1 -4 ALTERNATE PROGRAMMING METHOD FUNCTION CODE LOCAL PRO G RAMMIN G TELEPHONE PR O G RAMMIN G 34 COPY ALL MASTER MEMOR Y TO SUB-UNITS T o synchronize programming in multi-unit installations , all system da ...

  • Linear AE-100 - page 29

    29 MODEL AE-1 00 VER X.X 1 TO CONFIRM: TALK TIME: 060 ALTERNATE PROGRAMMING METHOD OPEN TIME: 4 LOCK-OUT COUNT:3 FUNCTION CODE LOCAL PRO G RAMMIN G TELEPHONE PR O G RAMMIN G 46 DISPLA Y SYSTEM INFORMA TION The Model number and fi rmware version installed in the AE-100 can be display ed. Step 1 Enter Function Code 46, then press #. Step 2 The displ ...

  • Linear AE-100 - page 30

    30 AUTO-ANSWER=1 : ENA=1 DISA=0: BEEP ON=1 OFF=0 UNLOCK BEEP(1 ,0) ALTERNATE PROGRAMMING METHOD FUNCTION CODE LOCAL PRO G RAMMIN G TELEPHONE PR O G RAMMIN G 74 A UTOMA TIC TELEPHONE ANSWER The factory setting will allow the system to detect a ring signal on the telephone line and answer the call. NO TE: The automatic ans wer feature can be turned o ...

  • Linear AE-100 - page 31

    31 ENTER FUNCTION: T E N A N T C A L L B K = 0 ALTERNATE PROGRAMMING METHOD FUNCTION CODE LOCAL PRO G RAMMIN G TELEPHONE PR O G RAMMIN G 91 EXIT PROGRAMMING MODE Entering this command number will cause the unit to exit programming mode and return to normal operation. Step 1 T o exit prog ramming mode, enter Function Code 91, then press #. NO TE: Th ...

  • Linear AE-100 - page 32

    32 DI G ITAL S PEECH VOLUME ADJU S TMENT S PEAKE R PHONE VOLUME ADJU S TMENT DI S PLAY CONT R A S T ADJU S TMENT AE-100 CI R CUIT BOA R D MO R E LE SS AE-100 CI R CUIT BOA R D POWE R PHONE S TATU S R ELAY B ATTE R Y R E S ET B UTTON Sys tem A d jus tments The factory settings are suffi cient for most installations . The system can be adjusted to c ...

  • Linear AE-100 - page 33

    33 P R E SS S TA R FI RS T TO CLEA R THE KEYPAD (OPTIONAL), THEN KEY IN A DI R ECTO R Y ENT R Y CODE O R S TAND-ALONE ENT R Y CODE UP TO 8 S ECOND S A R E ALLOWED B ETWEEN EACH KEY S T R OKE UP TO 40 S ECOND S A R E ALLOWED TO KEY IN THE ENTI R E ENT R Y CODE ALL FOU R DI G IT S MU S T B E ENTE R ED, INCLUDIN G LEADIN G ZE R O S IF A MI S TAKE I S ...

  • Linear AE-100 - page 34

    34 9-3/4" 11-3/4" 3-1/2" Model CCM-1 Color CCTV Camera (P/N A CP00904) Model TR-100 T rim Ring (P/N ACP00941) Model GNC-1 Curb-mount Gooseneck (P/N A CP00906) Model GNB-1 Burial-mount Gooseneck (P/N A CP00907) Specifi cations MECHANICAL Case dimensions: 9- 3 /4” W x 11- 3 /4” H x 3 -1/2” D ELECTRICAL Input P ower: 16 V AC from ...

  • Linear AE-100 - page 35

    35 T r oubleshooting System completely dead 1. No power from transf or mer . Check voltage at AE-100 transf or mer terminals. 2. V erify that ter minal bloc ks are fi rmly plugged into circuit board. Buzz on speaker 1. Check f or 16 volt A C power shorted to wiring conduit. 2. Check f or telephone line shor ted to ground. 3 . V erify that telephon ...

  • Linear AE-100 - page 36

    Copyright © 2008 Linear LLC 225787 C ...

メーカー Linear カテゴリー Automobile Electronics

Linear AE-100のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AE-100の取扱説明書
- Linearの製品カード
- パンフレット
- またはLinear AE-100の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Linear AE-100の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Linear AE-100の取り付け説明書、サービスマニュアル、簡易説明書、またはLinear AE-100のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Linear AE-100の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Linear AE-100デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLinear AE-100を使用するのを助ける技術的文書のことです。説明書は通常、全てのLinear AE-100ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Linearの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Linear AE-100の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLinear AE-100の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Linear AE-100に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Linear AE-100デバイスの基本機能を使うにあたってのヒント。 Linear AE-100のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Linear AE-100に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLinear AE-100のメーカー/サービスへの連絡先に関する情報。

Linear AE-100についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLinear AE-100の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLinear AE-100で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (1)

Richard

Button spring broken