United States Stove 1500の取扱説明書

24ページ 0.78 mb
ダウンロード

ページに移動 of 24

Summary
  • United States Stove 1500 - page 1

    1 C O M P A N Y U N I T E D S T A T E S S T O V E C S S U H T B L S T A O Models 1500 & 1537G OWNERS MANUAL SOLID FUEL WARM AIR FURNACE *FOR PARALLEL INSTALLATION WITH EXISTING FORCED AIR-GAS OR OIL FIRED FURNACE (U.S. ONLY) *FOR INSTALLATION AS A CENTRAL FURNACE *THE 1500 & 1537G HOTBLAST FUR- NACES HAS BEEN APPROVED FOR U.S. INSTALLATIONS ...

  • United States Stove 1500 - page 2

    2 NOTE: YOUR UNIT MUST BE INSTALLED BY A QUALIFIED FURNACE INSTALLER. You've purchased one of America's Finest Wood and Coal Burning Furnaces. By heating with wood and coal you're helping CONSERVE AMERICA'S ENERGY! Wood is our Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one tree eac ...

  • United States Stove 1500 - page 3

    3 CAUTION! CLEANOUT OF THE HEAT EXCHANGER, FLUE PIPE, CHIMNEY, AND DRAFT INDUCER (IF USED), IS ESPECIALLY IMPORTANT AT THE END OF THE HEATING SEASON TO MINIMIZE CORROSION DURING THE SUMMER MONTHS, CAUSED BY ACCUMULATED ASH. Caution Labels Caution Labels Caution Labels Caution Labels Caution Labels Your Furnace has the following labels. Read and Obe ...

  • United States Stove 1500 - page 4

    4 1. Check your local codes. The installation must comply with their rulings. 2. Do not install this furnace in a mobile home or trailer. 3. Always connect this furnace to a chimney and vent to the outside. Never vent to another room or inside a building. 4. Do not connect this furnace to an aluminum Type B gas vent. This is not safe and is prohibi ...

  • United States Stove 1500 - page 5

    5 Y our HOTBLAST Furnace is designed to be a supplemental or central heating source for your home. This Solid Fuel Furnace may be installed in conjunction with a properly operating central furnace that is listed or cer- tified in accordance with nationally recog- nized safety standards and equipped with the required controls and other safety featur ...

  • United States Stove 1500 - page 6

    6 DIMENSIONS OF FURNACE 32-1/8" 1-3/4" 9" 33-7/8" 49-1/8" 24-1/16" 40-11/16" Figure 1B 1400/1500 Figure 1 Models 1500/ 1537G CAUTION GASES THAT ARE DRIVEN FROM FRESH COAL MUST BE BURNED OR THEY WILL ACCUMULATE AND EXPLODE. NEVER SMOTHER A FIRE WHEN ADDING FRESH COAL. CAUTION DO NOT OPERATE WITH THE FEED AND/OR ASH ...

  • United States Stove 1500 - page 7

    7 Locating the Furnace 1. The furnace should be located in the same room as the central system and as close as possible, but not closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace. (See Fig. 2) The unit will require installatio ...

  • United States Stove 1500 - page 8

    8 10' 2' MIN. 3' MIN. 6" CHIMNEY CONNECTOR 6" ELBOW 6" SOLID DAMPER 6" BAROMETRIC DRAFT REGULATOR (OPTIONAL) REFER TO CHIMNEY MANUFACTURER'S INSTRUCTIONS AND PARTS. Chimney Connection Fig. 4 MASONRY CHIMNEY Before using an existing masonry chimney, clean the chimney and inspect the flue liner to be sure it is ...

  • United States Stove 1500 - page 9

    9 Rules for Connector Pipe Installation 1. The crimped end of the chimney connector fits inside the furnace flue collar. Install additional chim- ney connectors and elbow with the CRIMPED END TOWARD THE FURNACE. This will allow any condensation in the flue to run back into the furnace. Use 6" dia. steel pipe and elbows for connection to chimne ...

  • United States Stove 1500 - page 10

    10 Assembly of Furnace Your furnace requires the following items to be assembled or installed by the service person: Feed Door Pull Handle Feed Door Locking Handle Blowers and Blower Controls Electrical Connections Remove all parts from inside the furnace and inspect for damage, including the firebrick as some breakage could occur during shipment. ...

  • United States Stove 1500 - page 11

    11 Fig. 11 NOTE: Wire leads from the distribution blower are usually BOTH BLACK. Makes no difference which leads from the motors connects to the corre- sponding leads coming out of the conduit. ...

  • United States Stove 1500 - page 12

    12 Power Failure Instructions Operation after loss of power: 1. Remove filter if provided 2. Do not expect to keep home at normal tem- peratures. 3. Do not load fuel above bottom of feed door. Installation Please see all methods of Installation in Appendix at the rear of this booklet. Pipe to combustible: Sides: 21" Back: 18" The installa ...

  • United States Stove 1500 - page 13

    13 2" MIN. AIR SPACE REQUIRED BY CODE 18" MIN. CENTRAL FURNACE PLENUM TO CEILING 6" MIN. Figure 12 Operating Instructions FUEL, Models 1500 & 1537G Egg size (1-3/16" or larger) bituminous coal for residential furnaces, or any of the specially packed fireplace coals can be used. Coal with a low ash content (2% to 6%) is recom ...

  • United States Stove 1500 - page 14

    14 Service Hints Do not expect a furnace to draw. It is the chimney that creates the draft. Smoke spillage into the house or excessive build-up of water or creosote in the chimney are warnings that the chimney is not functioning properly. Correct the problem before using furnace. Possible causes are: 1. The connector pipe may be pushed into the chi ...

  • United States Stove 1500 - page 15

    15 26 27 28 29 30 31 32 33 34 35 36 37 Model 1500 & 1537G Repair parts ...

  • United States Stove 1500 - page 16

    16 KEY PART # DESCRIPTION QTY. 1 69509 Firebox Weldment 1 2 25467R Cabinet Side (Left & Right) (Color - Red) 2 * * 25467G Cabinet Side (Left & Right) (Color - Green) 2 3 88032 Flue Collar Gasket 1 4 40246 Flue Collar 1 5 23459 Cabinet Back (Color - Red) 1 * * 23459G Cabinet Back (Color - Green) 1 6 25466R Cabinet Top (Color - Red) 1 * * 254 ...

  • United States Stove 1500 - page 17

    17 1 2 10 11 9 7 12 5 4 6 8 3 7 13 KEY PART # DESCRIPTION QTY. - 68733 Thermostat Box Assembly (Color - Red) - * * 68733G Thermostat Box Assembly (Color - Green - 1 68722 Thermostat Panel Weldment 1 2 68732 Thermostat Cover Weldment (Color - Red) 1 * * 68732G Thermostat Cover Weldment (Color - Green) 1 3 23429 Thermostat Step Plate 1 4 23431 Fricti ...

  • United States Stove 1500 - page 18

    18 ...

  • United States Stove 1500 - page 19

    19 COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX APPENDIX INSTALLATION A ...

  • United States Stove 1500 - page 20

    20 INSTALLATION B INSTALLATION C COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX PLENUM COLLECTOR BOX COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX PLENUM ELBOW PLENUM TOP (OPTIONAL) ...

  • United States Stove 1500 - page 21

    21 ...

  • United States Stove 1500 - page 22

    22 2" MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION F 2" MINIMUM CLEARANCE DUCT WORK SOLID FUEL FURNACE INSTALLATION G COLD AIR RETURN TO FILTER BOX CENTRAL FURNACE INSTALLATION ...

  • United States Stove 1500 - page 23

    23 2" MINIMUM CLEARANCE EXISTING OIL, ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE INSTALLATION H EXISTING OIL, ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE (TOP VIEW) (FRONT VIEW) ...

  • United States Stove 1500 - page 24

    24 1. Smoking when feed door a ) Insufficient Draft. a ) Set Thermostat higher. is open. b ) Clogged chimney or chimney b ) Clean Chimney. connector. c) Down draft in chimney. c) Add raincap to chimney. 2. Furnace does not heat. a ) Wood not seasoned and dry. a ) Allow wood to season in a dry area for six months. b ) Insufficient flue draft. b ) Se ...

メーカー United States Stove カテゴリー Furnace

United States Stove 1500のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1500の取扱説明書
- United States Stoveの製品カード
- パンフレット
- またはUnited States Stove 1500の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、United States Stove 1500の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、United States Stove 1500の取り付け説明書、サービスマニュアル、簡易説明書、またはUnited States Stove 1500のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、United States Stove 1500の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

United States Stove 1500デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUnited States Stove 1500を使用するのを助ける技術的文書のことです。説明書は通常、全てのUnited States Stove 1500ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

United States Stoveの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. United States Stove 1500の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUnited States Stove 1500の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。United States Stove 1500に関してこのドキュメントで見つけることができる全てのヒントの目次
3. United States Stove 1500デバイスの基本機能を使うにあたってのヒント。 United States Stove 1500のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。United States Stove 1500に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUnited States Stove 1500のメーカー/サービスへの連絡先に関する情報。

United States Stove 1500についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUnited States Stove 1500の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUnited States Stove 1500で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)