Graham Field 750000の取扱説明書

20ページ 0.46 mb
ダウンロード

ページに移動 of 20

Summary
  • Graham Field 750000 - page 1

    750000 AL TERNA TING PRESSURE / L OW AIR L OSS MA TTRESS SYSTEM USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. Info: The most current version of this manual can be found online at www.grahameld.com. 750000-INS-LAB-RevC11 ...

  • Graham Field 750000 - page 2

    2 750000-INS-LAB-RevC11 CONTENTS INTRODUCTION..................................................................................... 3 INTENDEDUSEOFTHISDEVICE ........................................................ 3 CONTRAINDICA TION ...................................................................... 3 IMPORT ANTSAFETY ...

  • Graham Field 750000 - page 3

    750000-INS-LAB-RevC11 3 INTR ODUCTION Use this manual for set-up and operation of the Lumex AltaDyne 750000 Alternating Pr essure / Low Air Loss Mattr ess System. Read all instructions before using the mattr ess system. Save this manual for future r eference. INTENDED USE OF THIS DEVICE The intended use of the Lumex AltaDyne 750000 Alternating P ...

  • Graham Field 750000 - page 4

    4 750000-INS-LAB-RevC11 IMPORT ANT SAFETY PRECA UTIONS The safety statements pr esented in this chapter refer to the basic safety information that should be obser ved by those using the Alternating Pr essure / Low Air Loss Mattr ess System. There ar e additional safety statements in other chapters or sections, which may be the same as or similar ...

  • Graham Field 750000 - page 5

    750000-INS-LAB-RevC11 5 WARNING To reducetheriskofburns,electrocution,r e,or personalinjury:  W ARNING:Donotleavethisproductunattended whenpluggedin.  W ARNING: Alwaysuseclosesupervisionwhenthis productisused b y, on,ornearchildrenor ...

  • Graham Field 750000 - page 6

    6 750000-INS-LAB-RevC11  W ARNING:Patiententrapmentwithbedsiderails maycauseinjuryordeath.Thebedframeandits components,includingthemattress,bedsiderails, headandfootboard,bedding,andanyaccessories addedtothebed,canallaffectthe? ...

  • Graham Field 750000 - page 7

    750000-INS-LAB-RevC11 7 EQUIPMENT SYMBOLS Attention! Consult accompanying documents (this manual) “BF”symbol: Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment Functional earth (for UL only) Class II (for UL only) Disposal of Electrical & Electronic Equipment (WEEE): D ...

  • Graham Field 750000 - page 8

    8 750000-INS-LAB-RevC11 PR ODUCT DESCRIPTION PUMP AND MA TTRESS SY STEM pumpandmattresssystem CPRvalves mattress-pump connectors mattress footend symbol pump Pump: front quick connector ...

  • Graham Field 750000 - page 9

    750000-INS-LAB-RevC11 9 Pump: rear Pump: top panel pressur eadjustmentknob normalpressur eindicator lowpressur eindicator mainpowerswitch staticfunctionswitch Pr essur e adjust knob : The pressur e adjust knob controls the air pr essure output. T urn it clockwise to increase output pr essure (rmer); turn it count ...

  • Graham Field 750000 - page 10

    10 750000-INS-LAB-RevC11 Static function switch : Pr ess the static function switch to suspend alternating function, if needed; the pr essure inside the air tubes will then be adjusted to identical pr essure. Pr ess the static function switch again to change back to alternating mode. The static function switch toggles between static and alternat ...

  • Graham Field 750000 - page 11

    750000-INS-LAB-RevC11 11 INST ALLA TION UNP ACKING 1. Befor e unpacking, check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field equipment pr ovider . 2. Remove all loose packing fr om the car ton. 3. Car efully remove all components fr om the car ton. 4. Inspect all component ...

  • Graham Field 750000 - page 12

    12 750000-INS-LAB-RevC11 PUMP AND MA TTRESS INST ALLA TION 1. Place the mattr ess on top of the bed frame; ensur e that the foot end symbol faces up at foot end as shown at right. 2. Fold open the wir e hangers on the back of the pump as shown at right. 3. Either hang the pump on the bed's foot end as shown at right, or place the pump on a ...

  • Graham Field 750000 - page 13

    750000-INS-LAB-RevC11 13  W ARNING:Locateallcordssothattheywillnotbe steppedon,trippedover ,orotherwisesubjectedto damageorstress.  W ARNING:Donotuseahouseholdextensioncordif theelectricalcorddoesnotreachthepoweroutlet. Useo ...

  • Graham Field 750000 - page 14

    14 750000-INS-LAB-RevC11 OPERA TION 1. T urn the power switch to the ON position. 2. Adjust the pr essure adjust knob to the maximum position. Info: Set the pressure adjust knob to the maximum position for the quickest inflation at set-up; the mattress can then be adjusted to the desired pressure. 3. The pump will begin delivering air into the ...

  • Graham Field 750000 - page 15

    750000-INS-LAB-RevC11 15 under the patient's buttock ar ea; your ngers should just t. If the t is too loose, decr ease the setting. If your ngers do not t well, incr ease the setting two notches rmer . W ait ten minutes and then check again. Y ou should only have to adjust this setting one time per patient. Please consult ...

  • Graham Field 750000 - page 16

    16 750000-INS-LAB-RevC11 MAINTENANCE CLEANING Perform the following cleaning pr ocedures befor e use. Pump : W ipe the pump with a clean, damp cloth and mild deter gent, and keep it away fr om dust. Air dr y . s  NOTICE:Donotusephenolicproductsorcorrosive orpowderedcleanserstocleanthepump. s  NOTIC ...

  • Graham Field 750000 - page 17

    750000-INS-LAB-RevC11 17 Fuse replacement tool needed: small screwdriver 1. If you suspect a blown fuse, disconnect the plug fr om the wall outlet immediately . 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse locations ar e shown in pictur e at right). 3. Insert a new fuse of the correct rating (T1A/250V , VDE appr oved ...

  • Graham Field 750000 - page 18

    18 750000-INS-LAB-RevC11 SPECIFICA TIONS Pump Specication Power Supply 120V System: AC 120V 60 Hz Info: see rating label on product Fuse Rating T1A, 250V Cycle time 8 minutes Air input >4 LPM Dimensions (L x W x H) 9.8" x 5.3" x 3.7" (25 x 13.5 x 9.5 cm) Weight 4 lb (1.8 kg) Environment T emperature Operation: 50°F to 104° ...

  • Graham Field 750000 - page 19

    750000-INS-LAB-RevC11 19 WARRANTY GF Health Pr oducts, Inc. warrants the Lumex AltaDyne 750000 Alternating Pr essure / Low Air Loss Mattr ess System for a period of twelve months for defects in workmanship and materials. If a pr oduct is deemed to be under warranty , GF Health Products, Inc. shall pr ovide, at its option, (1) r eplacement of any ...

  • Graham Field 750000 - page 20

    USA Corporate Headquar ters: GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 770-368-4700 fax: 770-368-2386 www .grahamfield.com © 2011, GF Health Products, Inc. ...

メーカー Graham Field カテゴリー Camping Equipment

Graham Field 750000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 750000の取扱説明書
- Graham Fieldの製品カード
- パンフレット
- またはGraham Field 750000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graham Field 750000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graham Field 750000の取り付け説明書、サービスマニュアル、簡易説明書、またはGraham Field 750000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graham Field 750000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graham Field 750000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraham Field 750000を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraham Field 750000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Graham Fieldの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graham Field 750000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraham Field 750000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graham Field 750000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graham Field 750000デバイスの基本機能を使うにあたってのヒント。 Graham Field 750000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graham Field 750000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraham Field 750000のメーカー/サービスへの連絡先に関する情報。

Graham Field 750000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraham Field 750000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraham Field 750000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。