Carrier 90MUの取扱説明書

22ページ 0.4 mb
ダウンロード

ページに移動 of 22

Summary
  • Carrier 90MU - page 1

    90MA/MU Single-Package Marine Cooling Units Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 1 Installation, Operation and Service Instructions SAFETY CONSIDERATIONS The 90MA/MU Units ar ...

  • Carrier 90MU - page 2

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 2 TABLE 1A - 90MA /MU PHYSICAL DA TA – R-134A , ENGLISH UNITS (See Table 2A for SI units) LEGEND FPT = Female Pipe T hread MPT = Male P ...

  • Carrier 90MU - page 3

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 3 TABLE 1B - 90MA /MU PHYSICA L DATA – R-407C , ENGLISH UNITS (See Table 2B for SI units) LEGEND FPT = Female Pipe T hread MPT = Male P ...

  • Carrier 90MU - page 4

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 4 TABLE 1C - 90MA /MU PHYSICA L DATA – R-404A , ENGLISH UNITS (See Table 2C for SI units) LEGEND FPT = Female Pipe T hread MPT = Male P ...

  • Carrier 90MU - page 5

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 5 TABLE 2A - 90MA /MU PHYSICAL DA TA – R-134A , SI UNITS LEGEND FPT = Female Pipe T hread MPT = Male Pi pe Thread ODF = Outside Diamete ...

  • Carrier 90MU - page 6

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 6 TABLE 2B - 90MA /MU PHYSICA L DATA – R-407C , SI UNITS LEGEND FPT = Female Pipe T hread MPT = Male Pi pe Thread ODF = Outside Diamete ...

  • Carrier 90MU - page 7

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 7 TABLE 2C - 90MA /MU PHYSICA L DATA – R-404A , SI UNITS LEGEND FPT = Female Pipe T hread MPT = Male Pi pe Thread ODF = Outside Diamete ...

  • Carrier 90MU - page 8

    FIGURE 1 - BA SE UNIT INTERIOR DETAILS (TYPICA L UNIT SHOWN) Step 4 - Rig and Place Unit - NOTE: Install accessories before placing unit. a. Provide space around unit for service, filter access, and overhead clearance as indicated in Figure 2. b. Move and store unit in upright position. c. Use slings with spacer under base skid to prevent panel dam ...

  • Carrier 90MU - page 9

    DIMENSION “D” MUST BE EQUAL ALL AROUND FIGURE 3 - HORIZONTA L WHEEL CENTERING FIGURE 4 - CONCENTRIC WHEEL A LIGNMENT Step 6 – Check Fan Shaft and W heel Alignme nt - HORIZONTAL WHEEL CENT ERING - All wheels must be horizontally centered betw een the inside edges of their fan scroll ventures (Figure. 3). Adjust as follows: a. Loosen set screws ...

  • Carrier 90MU - page 10

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 10 a. Route regulating valve capilla ry w ith its flare nut to the fitting on refrigerant discharge line (Figure. 1), using any convenien ...

  • Carrier 90MU - page 11

    TA BLE 3 - RECOMMENDED LINE SIZ ES (INCHES) REMOTE CONDENSERS DISCH LIQ UID DISCH LIQUID DISCH LIQUID DISCH LIQ UID 404 R-407C 1/2 3/8 5/8 3/8 5/8 3/ 8 5/8 3/8 406 R-407C 5/8 3/8 3/4 3/8 3/4 3/ 8 3/4 3/8 408 R-407C 3/4 1/2 3/4 1/2 7/8 1/ 2 7/8 1/2 412 R-407C 7/8 1/2 7/8 1/2 7/8 1/2 1-1/8 5/8 504 R-404A 5/8 3/8 5/8 3/8 3 /4 3/8 3/4 3/8 506 R-404A 3/ ...

  • Carrier 90MU - page 12

    Step 12 - Make Electrical Connections GENERAL - Provide an adequate fused disconnect switch within sight of the unit. Provision for locking sw itch open (OFF) is advisable to prevent power from being turned on when unit is being serviced. POWER WIRING - Conduit opening for all units is on left side of unit near control box. Connect field power w ir ...

  • Carrier 90MU - page 13

    SERVICE WARNING NEVER reach into unit while fan is running. LOCK OPEN AND TAG unit disconnect before working on fan. Remove fuses and take them with you after noting this on tag . CAUTION 1. Sharp edges of coil fins are exposed. To prevent injury, cover top of evaporator with cardboard or a few layers of heavy tape. 2. To avoid coil damage, cover e ...

  • Carrier 90MU - page 14

    Eva porator Coil - Observe fan compartment Caution note at the beginning of the Service section. Remove dirt and debris from evaporator coil as required by condition. Clean coil w ith a stiff brush, vacuum cleaner or compressed air. Use a fin comb of the correct tooth spacing (Refer to Tables 1A/B/C/2A/B/C for coil fins/inch) when straightening mas ...

  • Carrier 90MU - page 15

    Charging the System (90MA) - These units are shipped with a full operating charge. If recharging is necessary (complete charge lost), wei gh in amount of refrigerant indicated on unit nameplate and in Table 1. If unit has partial charge, it must be recharged by removing existing charge and recharging by w eighing in the required amount of refr iger ...

  • Carrier 90MU - page 16

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 16 compressor equipped units and on the suction line on all other units. Oil Charge - All units are factory charged w ith oil. On 06D com ...

  • Carrier 90MU - page 17

    FOR NOTES AND LEGEND, SEE FIGURE 13 FIGURE 12 WIRING SCHE MATIC - 90MA/MU*04/*06 Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 17 ...

  • Carrier 90MU - page 18

    FIGURE 13 COMPONENT ARRA NGEMENT - 90MA/MU*04/*06 Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 18 ...

  • Carrier 90MU - page 19

    FOR NOTES AND LEGEND, SEE FIGURE 15 FIGURE 14 - ELECTRICAL SCHEMATIC - 90MA/MU*08/*12 Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 19 ...

  • Carrier 90MU - page 20

    FIGURE 15 - COMPONENT ARRANGEMENT - 90MA/MU008/012 Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 20 ...

  • Carrier 90MU - page 21

    FIGURE 16 – MOUNTING BASE ASSEMBLY – 90MA/MU*04/*06 Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 21 ...

  • Carrier 90MU - page 22

    Manufacturer reserves the right to discont inue, or change at any time, specifications or designs without notice and without incurring obligations Printed in U.S.A. 90MA-3SI SUPERCEDES FORM 62-02971-00 09-2009 Pg 22 FIGURE 17 – MOUNTING BASE ASSEMBLY – 90MA/MU*08/*12 ...

メーカー Carrier カテゴリー Air Conditioner

Carrier 90MUのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 90MUの取扱説明書
- Carrierの製品カード
- パンフレット
- またはCarrier 90MUの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Carrier 90MUの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Carrier 90MUの取り付け説明書、サービスマニュアル、簡易説明書、またはCarrier 90MUのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Carrier 90MUの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Carrier 90MUデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCarrier 90MUを使用するのを助ける技術的文書のことです。説明書は通常、全てのCarrier 90MUユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Carrierの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Carrier 90MUの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCarrier 90MUの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Carrier 90MUに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Carrier 90MUデバイスの基本機能を使うにあたってのヒント。 Carrier 90MUのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Carrier 90MUに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCarrier 90MUのメーカー/サービスへの連絡先に関する情報。

Carrier 90MUについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCarrier 90MUの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCarrier 90MUで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)