    1 Using Y our XP-600 Security System NAPCO © NAPCO 2005 OI301 1/05 ...

  • Napco Security Technologies XP-600 - page 2

    2 Introduction Congratulations on your purc hase of an adv anced N APCO EXPRESS XP-6 00 Security Sy stem. Me tic ulously developed by a leading manufacture r of state-of-the-art security products, th is system will provide you with unprecedented peace-of-mind and incorporates some of the most sophisticated features available to day. Above all, it h ...

  • Napco Security Technologies XP-600 - page 3

    3 Introduction SYSTEM INFORMATION Central Station Phone Number: ____________ ________ Central Station Account Number: ____________ ________ For Service Call: ____________ ________ Entry Delay: ____ ____________ ____ Exit Delay: ______________ ______ Alarm Time-out: ________ ____________ TABLE OF CONTENTS Keypad Controls and Indicators ............ ...

  • Napco Security Technologies XP-600 - page 4

    4 Keypad Controls and Indicators * Key Used to enable special functions and options. Press * and then the correspondin g Special Function num- ber Option (See Special Functions, Page 11) Bypass Key Used to bypass zones. Press Bypass and the corre - sponding zone numb er, and then Arm system. Numerical Keys 1-9, 0. Used to enter User Codes , Zone nu ...

  • Napco Security Technologies XP-600 - page 5

    5 Arming Your System When Leaving 1 Before arming your syste m, make sure the Green X Ready light is ON. Th is indicates that all of your protective zones are secure. If any zones are op en , the corresponding Zone light will be ON. Secure these zones before proceeding. If any zones cannot be secured, see Bypassing Zones below. 2 Enter your user co ...

  • Napco Security Technologies XP-600 - page 6

    6 Protecting Yourself While at Home 1 Before arming your system, make su re the Gree n X Ready light is ON. This indi cates that all of your protective zones are secure . If any zones are open, the correspond ing Zone light will be ON. S ecure those zones before proceeding. 2 Enter your user cod e. The Gr een X Ready light will go out, and the Red ...

  • Napco Security Technologies XP-600 - page 7

    7 Emergency Buttons The three sets of emerg ency buttons, if programmed , are always active whether the system is armed or disarmed. Discuss these Buttons with your installer. The emerge ncy signal will only be activated when the two respective buttons are pressed at the same time. Fire Alarm: Simultaneo usly press E + E to sound a fire alarm, and ...

  • Napco Security Technologies XP-600 - page 8

    8 Disarming Your System when Return ing 1 Enter your premises through the Entry/Exit door. The ke ypad will sound a steady tone to remind yo u to dis- arm the system before your Entr y Delay time expir es. 2 Enter your user code. The Red W Armed light w ill go out, indicating that the system has been disa rmed. Note: If you make a mistak e entering ...

  • Napco Security Technologies XP-600 - page 9

    9 Preparing a Fire Escape Plan Even with the most advanced fire alarm system, adequate protection requires an e scape plan. To prepare your plan, draw floor plans of your building (space is provided on the next page). Show two exits - a front or back door and a win- dow from each room. (Ma ke sure each windo w opens. You may need a sp ecial fire-es ...

  • Napco Security Technologies XP-600 - page 10

    10 Fire Protection Floor Plan Draw a plan of your premises below. ...

  • Napco Security Technologies XP-600 - page 11

    11 Special Functions A By pressing A fo llow ed by the appropriate ke y, (do not press simultaneously ) these special functions and features can be enabled: A 0 Easy Arm (when system is disarmed) The Easy Arm feature allows the system to b e armed by pressing A followed by 0 . This will allow the easy arm- ing of the system by someone who is no t a ...

  • Napco Security Technologies XP-600 - page 12

    12 The XP-600 is constantly monito ring its own component s, as well as all critical services, such as AC Power and the Telephone line, to insure that it is always ready to pro vide the protection for which it was designed. When a system troubl e does occur, it will cautio n you by lighting the yellow H SYSTEM light and beeping the keypad buzzer. I ...

  • Napco Security Technologies XP-600 - page 13

    13 H System Troubles Keypad Beeps or H SYSTEM Fla she s Zone ligh t ON System Trouble Condition Action 2 Beep s 2 Fire T roubl e A problem has been dete cted in the Fire Circuit. Call insta lling c ompa ny for se rvice. 2 Bee ps 3 Wir eles s Rec eiver T roub le A problem has been detected with the wireless re ceiver. Call insta lling c ompa ny for ...

  • Napco Security Technologies XP-600 - page 14

    14 Your Installer has assigne d a User 1 Code which may be used to not only Arm and Disarm the system, but also to enter the User Program Mode, whe re you can program other user c odes. The following expl ains how you will use this code to program or erase additional user codes. Entering the User Program Mode Press A followed by 8 and then enter th ...

  • Napco Security Technologies XP-600 - page 15

    15 Ambush Code - In the ev ent that y ou are forced by an intruder to disarm your system, this special code ca n be used to disarm the system, and simultaneously send a silent alarm to Central Sta tion. If your system ha s the Am bush featur e en- abled, the code assign ed as th e User 6 code will function as your Ambush Code. Arming / Disarming - ...

  • Napco Security Technologies XP-600 - page 16

    16 NAPCO LIMITED WARRANTY THE FOLLOWING STATEMENT IS RE QUIRED BY THE FCC . This equipmen t generates and uses radio-freque ncy ene rgy and , if not installed an d used prop erly, that is, in strict accordance w ith the manufacturer 's instructio ns, may cause in terference to radio and televi sion reception. It ha s been type teste d and foun ...

メーカー Napco Security Technologies カテゴリー Home Security System

Napco Security Technologies XP-600のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- XP-600の取扱説明書
- Napco Security Technologiesの製品カード
- パンフレット
- またはNapco Security Technologies XP-600の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Napco Security Technologies XP-600の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Napco Security Technologies XP-600の取り付け説明書、サービスマニュアル、簡易説明書、またはNapco Security Technologies XP-600のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Napco Security Technologies XP-600の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Napco Security Technologies XP-600デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNapco Security Technologies XP-600を使用するのを助ける技術的文書のことです。説明書は通常、全てのNapco Security Technologies XP-600ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Napco Security Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Napco Security Technologies XP-600の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNapco Security Technologies XP-600の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Napco Security Technologies XP-600に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Napco Security Technologies XP-600デバイスの基本機能を使うにあたってのヒント。 Napco Security Technologies XP-600のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Napco Security Technologies XP-600に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNapco Security Technologies XP-600のメーカー/サービスへの連絡先に関する情報。

Napco Security Technologies XP-600についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNapco Security Technologies XP-600の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNapco Security Technologies XP-600で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (1)

Noel

Bonjour Comment avoir la doc en Francais merci