    350 SIDE PV 026 Heater Sizes: 350,000 and 600,000 Btu/Hr Models: B350D and B600D ARL LOGO G 004 ® OWNER’S MANUAL HIGH PRESSURE POR T ABLE FORCED AIR HEA TERS 600 SIDE PV 027 IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future r ...

  • Desa B350D - page 2

    2 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some peop ...

  • Desa B350D - page 3

    3 099507 OWNER’S MANUAL PRODUCT IDENTIFICA TION Upper Shell Power Cord Thermostat Fuel Cap Fuel Tank Hot Air Outlet Lower Shell Power Cord Fuel Tank Hot Air Outlet Upper Shell Motor and Pump Assembly Fuel Cap Thermostat Figure 1 - 350,000 Btu/Hr Model Figure 2 - 600,000 Btu/Hr Model Motor and Pump Assembly Lower Shell Flame-Out Control Reset Butt ...

  • Desa B350D - page 4

    4 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR FUELS Do not use heavy fuels such as No. 2 fuel oil or No. 2 diesel. Using heavy fuels will result in: • clogged fuel filter and nozzle • carbon build-up on spark plug • the need of non-toxic anti-icer in fuel during very cold weather IMPORTANT: Use a KEROSENE ON ...

  • Desa B350D - page 5

    5 099507 OWNER’S MANUAL TO STOP HEATER OPERA TION TO START HEATER 1. Follo w all ventilation and safety infor - mation. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. Set thermostat dial to desired tempera- ture. Note: Thermostat setting must be higher than surrounding air temperature. 5. Plug power cord of heater into ...

  • Desa B350D - page 6

    6 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR PREVENT A TIVE MAINTENANCE SCHEDULE Item Fuel tank Filler neck screen Fuel filter assembly (Fuel tank) Fuel filter lines Fuel filter (Pump) Spark plug Fan blades and air deflectors Air passages around burner head Motor WARNING: Never service heater while it is plugg ...

  • Desa B350D - page 7

    7 099507 OWNER’S MANUAL OBSERVED PROBLEM WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Only a qualified service person should service and repair heater. TROUBLESHOOTING Motor does not start when heater is plugged in and thermostat setting is higher than surrounding air tempe ...

  • Desa B350D - page 8

    8 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR OBSERVED PROBLEM Heater will not ignite, but motor runs for a short period of time 1. A) Add fuel to tank. B) Check fuel tank for bubbles of w ater in bottom. If found, remov e fuel (see Storing, T ransporting, or Shipping , page 5). Clean tank and fuel filters (see Fu ...

  • Desa B350D - page 9

    9 099507 OWNER’S MANUAL OBSERVED PROBLEM Heater ignites, but flame-out control shuts off heater after a short period of time Heater burns, but puffs of smoke can be seen Heater does not burn steady Heater burns with odor Heater smokes continuously 1. Wrong pump pressure 2. Dirty fuel filters 3. Dirt in nozzle 4. Dirty photocell lens 5. Open or d ...

  • Desa B350D - page 10

    10 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR Figure 7 - Spark Plug Removal Spark Plug Wire Spark Plug Burner Head SPARK PLUG 1. Remove upper shell (see column 1). 2. Remove spark plug wire from spark plug (see Figure 7). 3. Remov e spark plug from burner head using 13/16" open-end wrench (see Figure 7). 4 . ...

  • Desa B350D - page 11

    11 099507 OWNER’S MANUAL Figure 9 - Replacing Nozzle PUMP (Procedure if Pump is Binding) 1. Remove upper shell (see page 10). 2. Loosen hex screw on flange clamp at rear of motor with 5/16" nut-driv er (see Figure 11). 3. T urn fan with hand (see Figure 12). 4. If fan turns freely , tighten screw on flange clamp. 5. If fan does not turn fre ...

  • Desa B350D - page 12

    12 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR Fuel Filter Fuel Lines FUEL FILTERS A. Tank Fuel Filter 1. Disconnect fuel lines from pump and pump fuel filter assembly with 7/16" wrench (see Figure 15). 2. Carefully pry fuel filter loose from fuel tank with flat end of screwdr iver . 3. Inspect fuel filter ...

  • Desa B350D - page 13

    13 099507 OWNER’S MANUAL SPECIFICA TIONS 350,000 Btu/Hr 600,000 Btu/Hr Output Rating (Btu/Hr) 350,000 600,000 Fuel Use Only Kerosene or No. 1 Fuel Oil Fuel Tank Capacity (U.S. Gallons) 30 36 Fuel Consumption (Gallons Per Hr) 2.5 4 Electric Requirements 120V/60 Hz 120V/60 Hz Amperage (Normal Run) 7.1 11 Motor RPM 1725 1725 Fuel Pump Pressure (PSI) ...

  • Desa B350D - page 14

    14 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR ILLUSTRA TED PA R T S BREAKDOWN 350,000 BTU/HR 1 2 2 4 5 21 2 7 8 9 10 13 11 12 14 15 16 19 20 21 4 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 37 38 34 2 39 2 40 4 6 20 13 3 17 18 41 ...

  • Desa B350D - page 15

    15 099507 OWNER’S MANUAL REF. NO. PART NO. DESCRIPTION QTY. 1 099329-02 Upper shell model B350D (Yellow) 1 2 M11084-27 Screw, #10-16 x 1/2" 15 3 M50542-01 Combustion chamber & shield 1 4 M30865-02 Bushing 7 5 M50086 Air deflector 5 6 † Burner head assembly 1 7 M16656-18 Photocell assembly 1 8 M50121 Fan 1 9 M50097-01AA Fan guard 1 10 ...

  • Desa B350D - page 16

    16 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR ILLUSTRA TED PA R T S BREAKDOWN 600,000 BTU/HR 1 2 2 3 4 5 13 6 7 45 46 8 9 10 11 13 14 21 18 17 15 16 23 22 24 25 33 2 4 28 30 26 27 34 25 16 2 35 36 41 42 15 43 43 44 39 38 37 15 29 12 40 2 19 20 2 4 31 32 47 ...

  • Desa B350D - page 17

    17 099507 OWNER’S MANUAL P ARTS LIST 600,000 BTU/HR REF. NO. PART NO. DESCRIPTION QTY. 1 099329-04 Upper shell model B600D (Yellow) 1 2 M11084-27 Screw, #10-16 x 1/2" 28 3 M50543-01 Combustion chamber & shield 1 4 M30865-02 Bushing 5 5 M50157 Air deflector 5 6 † Burner head assembly 1 7 104679-01 Photocell assembly 1 8 M50194 Fan 1 9 ...

  • Desa B350D - page 18

    18 099507 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR 4 9 8 7 6 5 3 1 2 REF NO. PART NO. DESCRIPTION QTY. 1 M10908-2 Screw, #6-32 x 3/8" (350,000 Btu/Hr Only) 2 2 099229-01 Photocell bracket (350,000 Btu/Hr Only) 1 3 HA3012 Spark plug 1 4 M50112 Nozzle (350,000 Btu/Hr) 1 M30765 Nozzle (600,000 Btu/Hr) 1 5 M51170-01 P ...

  • Desa B350D - page 19

    19 099507 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Desa B350D - page 20

    For information, write: DESA International, P.O. Box 90004 Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department When writing, always include Model number and Serial number. W ARRANTY AND REP AIR SERVICE PARTS AND SERVICE UNDER WARRANTY Should your heater require service, return it to your nearest authorized service center. Proof of ...

メーカー Desa カテゴリー Electric Heater

Desa B350Dのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- B350Dの取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa B350Dの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa B350Dの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa B350Dの取り付け説明書、サービスマニュアル、簡易説明書、またはDesa B350Dのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa B350Dの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Desa B350Dデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa B350Dを使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa B350Dユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa B350Dの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa B350Dの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa B350Dに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa B350Dデバイスの基本機能を使うにあたってのヒント。 Desa B350Dのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa B350Dに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa B350Dのメーカー/サービスへの連絡先に関する情報。

Desa B350Dについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa B350Dの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa B350Dで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)