Vanguard Heating FB32CAの取扱説明書

24ページ 1.93 mb
ダウンロード

ページに移動 of 24

Summary
  • Vanguard Heating FB32CA - page 1

    Sav e this manual for future reference. For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury , or loss of life. W ARNING: For use only with a listed gas-fired unvented decorative room heater . Not to exceed 40,0 ...

  • Vanguard Heating FB32CA - page 2

    www .desatech.com 105604-01H 2 W ARNING: Improper installation, adjustment, altera- tion, service, or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency , or the gas supplier . This app ...

  • Vanguard Heating FB32CA - page 3

    www .desatech.com 105604-01H 3 SAFETY INFORMA TION WA RNI NG: Th is pro duc t co n- ta ins a nd /or g en era tes c he mic als kn own t o t he St ate o f C al ifo rni a to ca use c an cer o r bir th de fe cts , or ot her re pro duc tiv e h arm . IMP ORT ANT : Rea d thi s own er’ s man ual caref ull y and compl ete ly be fo re tr y in g t o a sse m ...

  • Vanguard Heating FB32CA - page 4

    www .desatech.com 105604-01H 4 5. V ent-free gas log heaters installed in these fireboxes require fresh air ventilation to run properly . See Air for Combustion and V entila- tion, page 6. 6. Do not run firebox • wher e flammab le liqui ds or vap ors are used or stored • under dusty conditions 7. Do not use this firebox to cook food or burn ...

  • Vanguard Heating FB32CA - page 5

    www .desatech.com 105604-01H 5 12 1 / 2 " 2 3 / 4 " 1 1 / 2 " 9 3 / 4 " 4 5 / 8 " 2 1 / 2 " 6" 32 3 / 16 " 33 11 / 16 " Figure 2 - Firebox Side V iew Gas Line Access Standoffs (Models FB32NCA and NLFB32NC only) Electrical Access Hole Electrical Access Hole with Bushing 22 1 / 2 " 16 11 / 16 " 1 ...

  • Vanguard Heating FB32CA - page 6

    www .desatech.com 105604-01H 6 AIR FOR COMB USTION AND VENTILA TION W ARNING: This firebox shall no t b e i nst all ed in a co nfin ed spac e or unusu ally tight con stru c - tion unless provisions are provid- ed for adequate combustion and ventilation air . Read the following ins truc tio ns to in sure prop er fres h air for this and other fuel- ...

  • Vanguard Heating FB32CA - page 7

    www .desatech.com 105604-01H 7 DETERMINING FRESH-AIR FLOW FOR HEA TER LOCA TION Determining if Y ou Have a Confined or Unconfined Space Use this work sheet to determine if you have a confi ned or unco nfine d s pace . Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation gril ...

  • Vanguard Heating FB32CA - page 8

    www .desatech.com 105604-01H 8 AIR FOR COMB USTION AND VENTILA TION Continued VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining un - confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12&quo ...

  • Vanguard Heating FB32CA - page 9

    www .desatech.com 105604-01H 9 IMPORT ANT : V ent-free gas log heaters add moisture to the air . Although this is beneficial, installing firebox in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and V entilation , page 6. IMP ORT AN T : Make sure the firebox is level. If firebox is not ...

  • Vanguard Heating FB32CA - page 10

    www .desatech.com 105604-01H 10 INST ALLING BLOWER ACCESSOR Y (Model FB32CA only) Y ou may install blower accessory GA3700 with conventional installation (below) or with built-in installation (page 11) with models FB32CA and NLFB32C only . Conventional Installation of Blower Accessory NOTICE: If a log set is currently installed in the firebox, dis ...

  • Vanguard Heating FB32CA - page 11

    www .desatech.com 105604-01H 1 1 7. Plug in blower power cord. a. If your firebox is installed as a freesta nding unit, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1 1 / 2 " hole in the floor support on the exit side. Install the second plastic bushin ...

  • Vanguard Heating FB32CA - page 12

    www .desatech.com 105604-01H 12 INST ALLING LOG HEA TER IN FIREBOX CAUTI ON: Do not rem ove the da ta p lat es att ache d to the hea te r base assembly . The data plates contain important warranty and safety information. CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates. 1. Remove four screw ...

  • Vanguard Heating FB32CA - page 13

    www .desatech.com 105604-01H 13 Electrical Outlet INST ALLING FIREPLACE SCREEN 1. Insert each rod through nine rings located at top of screen. 2. Insert first rod into rear hole in left side of firebox. Fasten rod to rear hole near center of firebox using black shoulder screw . 3. Insert other rod into front hole on right side of firebox and fa ...

  • Vanguard Heating FB32CA - page 14

    www .desatech.com 105604-01H 14 7. Brea k off nail ing flang es (s ee Fi gure 19) w ith hamm er or p lier s. IMPORT ANT : When installing Brass T rim Kit , s ee i nstr uct ion s in clu ded wit h ma nte l accessory . 8. Place cardboard or other protective material on top of hearth base. Carefully set firebox on protective material, with back of ? ...

  • Vanguard Heating FB32CA - page 15

    www .desatech.com 105604-01H 15 2. Inst all ga s pip ing to firebo x loca tion. T his installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas pip - ing. See Connecting to Gas Supply in log set owner ʼ s manual. 3. Carefully se ...

  • Vanguard Heating FB32CA - page 16

    www .desatech.com 105604-01H 16 ACCESSORIES Purchase these firebox accessories from your local dealer . If they can not supply these accessories, call DESA Heating Productsʼ Sales Department at 1-866-672-6040 for information. Y ou can also write to the address listed on the back page of this manual. EQUIPMENT SHUTOFF V AL VE GA5010 All models. Eq ...

  • Vanguard Heating FB32CA - page 17

    www .desatech.com 105604-01H 17 ACCESSORIES Continued HARDWOOD CABINET HEARTH BASE GC3333F Series - W alnut Finished GC3334U Series - Unfinished GC3335F Series - Oak V eneer Finished GM3004W Series - Off White The cabinet hearth base creates a handsome riser for the firebox (cannot be used with corner mantel or face mantel). Dimensions (WxHxD): 5 ...

  • Vanguard Heating FB32CA - page 18

    www .desatech.com 105604-01H 18 ILL USTRA TED P ARTS BREAKDOWN MODELS FB32NCA AND NLFB32NC 5 14 16 16 16 13 15 17 17 17 16 6 1 7 16 18 10 8 20 12 19 9 4* 2* 3* 2* 16 1 1 18 ...

  • Vanguard Heating FB32CA - page 19

    www .desatech.com 105604-01H 19 KEY P ART NUMBER NO. FB32NCA NLFB32NC DESCRIPTION QTY . 1 101872-03 101872-03 Firebox T op 1 2 101889-01 * Firebrick Retainer 3 3 101929-04 * Rear Firebrick 1 4 101932-04 * Side Firebrick 2 5 103207-01 103207-01 Outer Casing 1 6 103208-01 103208-01 Outer Shell Base 1 7 ** ** Firebox Wrapper 1 8 103297-01 103297-01 As ...

  • Vanguard Heating FB32CA - page 20

    www .desatech.com 105604-01H 20 ILL USTRA TED P ARTS BREAKDOWN MODELS FB32CA AND NLFB32C 5 16 16 15 16 17 22 6 1 16 7 16 14 21 13 18 10 8 20 12 19 9 4* 2* 3* 2* 16 1 1 18 18 ...

  • Vanguard Heating FB32CA - page 21

    www .desatech.com 105604-01H 21 P ARTS LIST This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. KEY P ART NUMBER NO. FB32CA NLFB32C DESCRIPTION QTY . 1 101872-03 101872-03 Firebox T op 1 2 101889-01 * Firebrick Retainer 3 3 101929-04 * Rea ...

  • Vanguard Heating FB32CA - page 22

    www .desatech.com 105604-01H 22 NO TES __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ ________________ ...

  • Vanguard Heating FB32CA - page 23

    www .desatech.com 105604-01H 23 NO TES __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ ________________ ...

  • Vanguard Heating FB32CA - page 24

    2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com 105604-01 Rev . H 07/04 NOT A UPC WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory . W e reserve the right to amend these specifications at any time without notice. ...

メーカー Vanguard Heating カテゴリー Indoor Fireplace

Vanguard Heating FB32CAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FB32CAの取扱説明書
- Vanguard Heatingの製品カード
- パンフレット
- またはVanguard Heating FB32CAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vanguard Heating FB32CAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vanguard Heating FB32CAの取り付け説明書、サービスマニュアル、簡易説明書、またはVanguard Heating FB32CAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vanguard Heating FB32CAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vanguard Heating FB32CAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVanguard Heating FB32CAを使用するのを助ける技術的文書のことです。説明書は通常、全てのVanguard Heating FB32CAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vanguard Heatingの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vanguard Heating FB32CAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVanguard Heating FB32CAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vanguard Heating FB32CAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vanguard Heating FB32CAデバイスの基本機能を使うにあたってのヒント。 Vanguard Heating FB32CAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vanguard Heating FB32CAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVanguard Heating FB32CAのメーカー/サービスへの連絡先に関する情報。

Vanguard Heating FB32CAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVanguard Heating FB32CAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVanguard Heating FB32CAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)