    Dir ect Drive Oil Lube Portable Air Compr essor Instruction manual IMPORT ANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. Part No. A10055 -051-0 ESP AÑOL: PÁGINA 25 FRANÇAIS: P AGE 49 T o learn mor e about Porter -Cable visit our website at: http: ...

  • Porter-Cable CLFRP350 - page 2

    2- ENG A10055 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor o ...

  • Porter-Cable CLFRP350 - page 3

    3- ENG A10055 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions befor e using this equipment. HAZARD WARNING: Risk of explosion or fire How T o Prevent It What Could Happen It is nor ...

  • Porter-Cable CLFRP350 - page 4

    4- ENG A10055 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause pr operty damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk fr om Flying Objects The compressed air stream can cause soft tissue damage to exposed skin ...

  • Porter-Cable CLFRP350 - page 5

    5- ENG A10055 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr ...

  • Porter-Cable CLFRP350 - page 6

    6- ENG A10055 WARNING: Risk of Bur ns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will r emain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenanc ...

  • Porter-Cable CLFRP350 - page 7

    7- ENG A10055 Review and underst and all instruction s and warnings in this manual. Become famil iar with the operation and contr ols of the air c ompr essor . Keep operati ng area clear of all persons, pets, and obstacle s. Keep childr en away from the air compr essor at all times . Do not operate the produc t when fatigue d or un der the influenc ...

  • Porter-Cable CLFRP350 - page 8

    8- ENG A10055 GLOSSAR Y Become familiar with these terms befor e operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery . PSIG: Pounds per square inch gauge; a unit of measure of pr essure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, ...

  • Porter-Cable CLFRP350 - page 9

    9- ENG A10055 T o Add Oil T o Pump Risk of Unsafe Operation. DO NOT A TTEMPT TO OPERA TE THIS AIR COMPRESSOR WITHOUT FIRST ADDING OIL TO THE CRANKCASE. Serious damage can r esult from even limited operation unless filled with oil and br oken in correctly . Make sure to closely follow initial start-up procedur es. Risk of Unsafe Operation. COMPRESSO ...

  • Porter-Cable CLFRP350 - page 10

    10- ENG A10055 INST ALLA TION GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compr essor is equipped with a cor d having a grounding wir e with an appropriate gr ...

  • Porter-Cable CLFRP350 - page 11

    11- ENG A10055 Extension Cor ds Using extension cords is not recommended. The use of extension cor ds will cause voltage to dr op resulting in power loss to the motor and overheating. Instead of using an extension cor d, increase the working r each of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as ...

  • Porter-Cable CLFRP350 - page 12

    12- ENG A10055 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future refer ence. Description of Operation Become familiar with these controls bef ...

  • Porter-Cable CLFRP350 - page 13

    13- ENG A10055 Dipstick : Indicates the amount of oil in the pump, the + mark indicates full and the - mark indicates oil needs to be added. See Oil paragraphs in the Maintenance section for instructions. Motor Thermal Overload Pr otector (not shown): The motor has an automatic reset thermal overload protector . If the motor overheats for any reaso ...

  • Porter-Cable CLFRP350 - page 14

    14- ENG A10055 How to Start: 1. T urn the On/Auto/Off lever to "ON/AUTO" and allow tank pressure to build. Motor will stop when tank pr essure reaches "cut-out" pressur e. 2. Pull the regulator knob out and turn clockwise to incr ease pr essure. When the desired pressure is r eached push knob in to lock in place. The compressor ...

  • Porter-Cable CLFRP350 - page 15

    15- ENG A10055 MAINTENANCE Customer Responsibilities Daily or after each use Before each use ● ● ● ● Every 8 hours Every 40 hours Every 100 hours ● ● 1 1- mor e frequent in dusty or humid conditions Check Safety V alve Drain T ank Oil Leaks Check Oil Change Oil Air Filter NOTE: See "Operation" section for the location of contr ...

  • Porter-Cable CLFRP350 - page 16

    16- ENG A10055 5. Drain water from air tank by opening drain valve (counter -clockwise) on bottom of tank. Risk of Bursting. W ater will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. 6. After the water has been drained, close the drain valve (clockwise). The air compressor c ...

  • Porter-Cable CLFRP350 - page 17

    17- ENG A10055 Air Filter - Inspection and Replacement Risk of Burns. Compressor head and cylinder sleeve are very hot. Do not touch. Allow compressor to cool prior to servicing. A dirty air filter will not allow the compressor to operate at full capacity . Keep the air filter clean at all times. 1. Set the On/Auto/Off lever to "OFF" and ...

  • Porter-Cable CLFRP350 - page 18

    18- ENG A10055 T o Replace or Clean Check V alve 1. Releas e all a ir pressu re fr om air tank. See "T o Drain T ank" in the Mainte nance sectio n. 2. Unplug unit. 3. Using an adjustab le wrench loosen outlet tube n ut at ai r tank and pu mp. Car efully m ove outlet tube away from check valve. 4. Using an adjustab le wrench loosen pr essu ...

  • Porter-Cable CLFRP350 - page 19

    19- ENG A10055 STORAGE Before you stor e the air compr essor , make sur e you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to "OFF" and unplug unit. 3. Risk of Flying Objects. Pull the regulator knob out and turn counter ...

  • Porter-Cable CLFRP350 - page 20

    20- ENG A10055 TROUBLESHOOTING PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when compressor reaches "cut- out" pr essure. Pressur e switch "cut-out" too high. Move On/Auto/Of f lever to the "OFF" position, if the unit does not shut of f contact a T rained Service T echnician. Contact a T rained Ser ...

  • Porter-Cable CLFRP350 - page 21

    21- ENG A10055 PROBLEM CAUSE CORRECTION Compressor is not supplying enough air to operate accessories. Pressur e reading on the regulated pressur e gauge (if equipped) drops when an accessory is used. It is normal for "some" pressur e drop to occur . If ther e is an excessive amount of pr essure drop when the accessory is used, adjust the ...

  • Porter-Cable CLFRP350 - page 22

    22- ENG A10055 PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit breaker tripped. 1. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. 2. Check for proper fuse. Y ou should use a time delay fu ...

  • Porter-Cable CLFRP350 - page 23

    23- ENG A10055 PROBLEM CAUSE CORRECTION Knocking Noise. Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Compressor mounting screws loose. Tighten mounting screws,s ee Parts manual for tor que specifications. Carbon build-up in pump. Have checked by a T rained Service T ...

  • Porter-Cable CLFRP350 - page 24

    24- ENG A10055 LIMITED W ARRANTY PORTER-CABLE CORPORA TION warrants to the original pur chaser that all products covered under this warranty are free fr om defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pr essure washers, and generators, which have the following warranty ...

メーカー Porter-Cable カテゴリー Air Compressor

Porter-Cable CLFRP350のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CLFRP350の取扱説明書
- Porter-Cableの製品カード
- パンフレット
- またはPorter-Cable CLFRP350の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Porter-Cable CLFRP350の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Porter-Cable CLFRP350の取り付け説明書、サービスマニュアル、簡易説明書、またはPorter-Cable CLFRP350のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Porter-Cable CLFRP350の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Porter-Cable CLFRP350デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPorter-Cable CLFRP350を使用するのを助ける技術的文書のことです。説明書は通常、全てのPorter-Cable CLFRP350ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Porter-Cableの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Porter-Cable CLFRP350の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPorter-Cable CLFRP350の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Porter-Cable CLFRP350に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Porter-Cable CLFRP350デバイスの基本機能を使うにあたってのヒント。 Porter-Cable CLFRP350のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Porter-Cable CLFRP350に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPorter-Cable CLFRP350のメーカー/サービスへの連絡先に関する情報。

Porter-Cable CLFRP350についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPorter-Cable CLFRP350の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPorter-Cable CLFRP350で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)