    Installation and operating instructions Combi HP Thermostatic mixer shower T00219 2180206H March 2007 I nstallers please note these InstructIons are t o b e left wIth the user ...

  • HP COI 2180206H - page 2

    Combi HP ther mostatic mixer shower Introduction 1 Safety warnings 1 Main components 2 Siting requirements 3 T ypical suitable installations 4 Preparing the mixer valve 6 Siting of the shower 6 Fitting the shower to the wall - Exposed 7 Rising and falling supplies 7 Rear entry supplies 1 0 Fitting the shower to the wall - Built-in 1 3 Solid wall 1 ...

  • HP COI 2180206H - page 3

    1 Combi HP ther mostatic mixer shower INTRODUCTION SAFETY W ARNINGS C-006-A INTRODUCTION T his book contains all the necessary fitting and operating instructions for your T riton high pressure thermostatic mixer shower . Please read them carefully . Please read through the whole of this book before beginning your installation. T he installation MU ...

  • HP COI 2180206H - page 4

    2 Combi HP ther mostatic mixer shower 1. Inlet nuts and olives 2. Inlet elbows 3. V alve housing 4. Outlet adaptor 5. Outlet nut and olive 6. Outlet blanking plug 7. Cartridge assembly 8. Flow knob 9. T emperature knob 10. Knob trim 11. Max. temperature override button 12. Cover 13. Inlet trims 14. Outlet trim 15. Outlet blanking trim 16. Flush mou ...

  • HP COI 2180206H - page 5

    3 Combi HP ther mostatic mixer shower SITING REQUIREMENTS D-003-A SITE REQUIREMENTS The installation must be in accordance with W ater Regulations/Bylaws. Minimum running water pressure: 1 bar . Maximum running water pressure: 5 bar . Maximum static water pressure: 10 bar . For the best performance within the specified pressure range both hot and ...

  • HP COI 2180206H - page 6

    4 Combi HP ther mostatic mixer shower a) Instantaneous gas-heated showers, e.g. combination boilers (fig.2) The shower control MUST be installed with a multipoint gas water heater or combination boiler of a fully modulating design (i.e. where the water draw-off rate indirectly controls the gas flow to the burner). A drop tight pressure reducing val ...

  • HP COI 2180206H - page 7

    5 Combi HP ther mostatic mixer shower packages with a cold take off after the pressure reducing valve to the cylinder . The layout and sizing of pipework must be such that nominally equal inlet supply pressures are achieved and the effects of other draw-offs are minimised. d) Mains pressurised thermal store (fig.5) Packages of this type, fitted wit ...

  • HP COI 2180206H - page 8

    6 Combi HP ther mostatic mixer shower Height of showerhead and shower to suit user ’s requirement. Shower can be mounted either side of the riser rail T00225 Before starting the installation, make sure all the openings on the valve are carefully covered to prevent ingress of any debris etc. Note: It is not necessary to remove the control knobs at ...

  • HP COI 2180206H - page 9

    7 Combi HP ther mostatic mixer shower Exposed Note: The outlet of the shower must not be connected to anything other than the hose and showerhead supplied. DO NOT use jointing compounds on any pipe fittings for the installation. DO NOT solder fittings near of the shower unit, as heat transfer can damage components. Note: Suitable isolating valves ( ...

  • HP COI 2180206H - page 10

    8 Combi HP ther mostatic mixer shower T00022 Hose end (flat) Pipe end (chamfered) screws are slack allowing the inlet elbows to rotate to the correct position and move freely in and out of the valve housing (fig.8) . Place the valve housing centrally between the two pipes, and mark the two diagonal fixing holes (figs.9 and 1 0) . Remove the valve. ...

  • HP COI 2180206H - page 11

    9 Combi HP ther mostatic mixer shower If installing a riser rail, fit the outlet adaptor into the bottom outlet hole in the valve housing. The adaptor is sealed with an ‘O’ ring. Make sure the adapter is fitted with the pipe end in the valve housing (fig.17) Fit the blanking plug into the top outlet hole using an ‘O’ ring to seal it (fig.18 ...

  • HP COI 2180206H - page 12

    10 Combi HP ther mostatic mixer shower Rear entr y supplies Note: The final separation between pipe centres needs to be about 153 mm but absolute accuracy is not essential as the inlet elbows are adjustable between 146 mm and 160 mm (fig.23) . Using a spirit level, mark the route of incoming hot and cold water supply pipes at a distance of 153 mm c ...

  • HP COI 2180206H - page 13

    11 Combi HP ther mostatic mixer shower Remove the valve. Drill and plug the holes using the wall plugs supplied. Using two hexagonal nuts (supplied), refit the valve to the pipework. Make sure the hot inlet port (marked with the letter ‘H’ on the valve housing) is connected to the hot pipework which must be on the left. Tighten the inlet nuts w ...

  • HP COI 2180206H - page 14

    12 Combi HP ther mostatic mixer shower where it is required i.e. bottom outlet for fixed head, top outlet for a hose (fig.20) . Fit the inlet blanking trims on the underside of the cover (fig.28) . Fit the outlet trim over the outlet adaptor and slide the cover on (fig.19) . Secure the cover with two screws (fig.21) . Locate the lugs on the trim ri ...

  • HP COI 2180206H - page 15

    13 Combi HP ther mostatic mixer shower FITTING THE SHOWER TO THE WALL - BUIL T -IN FITTING THE SHOWER TO THE W ALL Opening needs to be at the bottom if using a bulkhead 200 m m 10 - 12.5 m m 48 m m 50 mm 35 m m 77.5 m m 65 mm 220 mm T00249 Fig.29 T00250 Fig.30 Flush fit Note: The outlet of the shower must not be connected to anything other than the ...

  • HP COI 2180206H - page 16

    14 Combi HP ther mostatic mixer shower T00251 T00253 Seal tight up to shroud T00252 Fig.31 Fig.32 Fig.33 shower from the top (falling), the bottom (rising) or the rear . Mark the route of the incoming and outgoing pipework. Note: The final separation between pipe centres needs to be about 153 mm but absolute accuracy is not essential as the inlet e ...

  • HP COI 2180206H - page 17

    15 Combi HP ther mostatic mixer shower Where this is not possible refer to the ‘flushing procedure’ on page 20. Refit the valve to the mounting bracket/wall surface and pipework (fig.32) . Tighten the inlet nuts and inlet elbow grub screws. If fitting a fixed head, refer to the ‘Fitting the fixed head’ section and complete the outlet pipewo ...

  • HP COI 2180206H - page 18

    16 Combi HP ther mostatic mixer shower Fit the flush mount cover (fig.37) . Locate the lugs on the trim ring in the holes on the cover (fig.38) and twist clockwise. Complete the fitting of your shower accessories. Hollow wall The wall mounting bracket supplied with the shower is suitable for use on a plasterboard wall of 9.5 mm or 12.5 mm in thickn ...

  • HP COI 2180206H - page 19

    17 Combi HP ther mostatic mixer shower washer . Make sure the inlet elbows are positioned the correct way . Offer the valve up to the mounting bracket and secure using the screws provided (fig.42) . Complete the pipework to the shower marking off the length to enter the elbows. Remove the valve and cut the pipes to length. Flush pipework to clear t ...

  • HP COI 2180206H - page 20

    18 Combi HP ther mostatic mixer shower T00253 Seal tight up to shroud drill and plug the holes. Note: If fitting to plasterboard, use suitable cavity fixings. Break off the alignment tabs on the flush mount plate (fig.36). Place a ring of silicon sealant round the plate so that the plate seals against the wall. Secure the plate to the wall using th ...

  • HP COI 2180206H - page 21

    19 Combi HP ther mostatic mixer shower correct way . Offer the valve up to the mounting bracket and secure using the screws provided. Secure the mounting bracket together with the valve to the panel using two bolts in the innermost fixing holes (fig.46) . Complete the pipework to the shower marking off the length to enter the elbows. Remove the val ...

  • HP COI 2180206H - page 22

    20 Combi HP ther mostatic mixer shower Removal and/or fitting of check valves for maintenance IMPORT ANT : It is preferable to flush the pipework before installing the valve. Where this is not possible, the procedure using a flushing cartridge should be followed. a. Isolate the supplies. b. Remove the trim ring by twisting anti- clockwise. c. Remov ...

  • HP COI 2180206H - page 23

    21 Combi HP ther mostatic mixer shower FITTING THE T AMPERPROOF FIXED HEAD - EXPOSED FITTING THE T AMPERPROOF FIXED HEAD (Exposed option only) Complete the outlet pipework from the valve and cut the pipe to required length. Place the fixed head unit on top of the pipe work and mark the position of the three fixing holes (fig.54) . Drill and plug th ...

  • HP COI 2180206H - page 24

    22 Combi HP ther mostatic mixer shower FITTING THE T AMPERPROOF FIXED HEAD - BUIL T -IN FITTING THE T AMPERPROOF FIXED HEAD (Built in option only) Complete outlet pipework from the valve ending in a ½” BSP female threaded fitting (not supplied) (fig.59) . Note: The depth of thread on the fixed head unit from wall surface is 18 mm (fig.60) . It i ...

  • HP COI 2180206H - page 25

    23 Combi HP ther mostatic mixer shower FITTING THE FIXED HEAD - BUIL T -IN FITTING THE FIXED HEAD (Built in option only) The outlet pipe should protrude from the surface of the wall between 50 mm and 65 mm (fig.65) . Mark four fixing hole positions by using the fixed arm as a template. Drill and plug the wall using the plugs supplied. Care must be ...

  • HP COI 2180206H - page 26

    24 Combi HP ther mostatic mixer shower T00081 Appropriate fitting (Riser rail option only) Complete the outlet pipework ending in a ½" x 15 mm female thread fitting (fig.68) . Note: This fitting is not supplied as variations in installations needs the selection of the most suitable fitting. Screw the supplied male-thread connector into the fe ...

  • HP COI 2180206H - page 27

    25 Combi HP ther mostatic mixer shower Make sure all plumbing supplies are connected and turned on. Starting the shower T o start the shower , turn the outer knob (flow control) anti-clockwise (fig.74) . Adjusting the shower temperature T o adjust the temperature, turn the inner knob — temperature control (fig.75) . The temperature disc is number ...

  • HP COI 2180206H - page 28

    26 Combi HP ther mostatic mixer shower T00297 0D[LPXPWHPSHUDWXUHVWRSPHFKDQLVP 'HFUHDVHVWRSSRVLWLRQ,QFUHDVHVWRSSRVLWLRQ 7 5 , 7 2 1  7 5 , 7 2 1  *URRYHV 7 HPSHUDWXUHFRQWUROGLVF T00296 Fi xi ng sc re w T e mp era tu re co nt ro l k no b T e mp era tu re co nt ro ...

  • HP COI 2180206H - page 29

    27 Combi HP ther mostatic mixer shower T00298 1. HP valve cartridge (built-in valve) 83304970 2. HP cartridge and brass housing (exposed valve) 83304960 3. Outlet adaptor chrome 7031462 gold 7031463 4. Inlet elbow assembly 83303810 5. Outlet blanking plug 7031460 6. Cartridge ‘O’ rings 83303710 7. Knob set − white 83304810 8. Knob trim 705146 ...

  • HP COI 2180206H - page 30

    28 Combi HP ther mostatic mixer shower T00299 SP ARE P ARTS 14. Bulkhead assembly white 83303780 chrome effect 83303770 gold effect 83303790 − T rim disc (use with flush gold effect) 7051451 15. Inlet & outlet nuts 83303660 16. Spanner 7011766 − Flow regulator 22003530 17. Check valve/sleeve assembly 83303810 18. W all bracket 7011453 19. C ...

  • HP COI 2180206H - page 31

    29 Combi HP ther mostatic mixer shower X-006-A T urn the control knob anti-clockwise. T urn the control anti-clockwise. Reduce the simultaneous demand from supply — make sure a dedicated supply to mixer . Contact Customer Service for advice on flow regulators. Clean – refer to ‘Flushing Procedure’ . T urn the temperature control clockwise. ...

  • HP COI 2180206H - page 32

    30 Combi HP ther mostatic mixer shower FAUL T FINDING Problem/Symptom Cause Action/Cure X-006-A T urn t h e contro l k no b anti-c l oc k wise. T urn the control anti-clockwise. Reduce the simultaneous demand from supply — make sure a dedicated supply to mixer . Contact Customer Service for advice on flow regulators. Clean – refer to ‘Flushi ...

  • HP COI 2180206H - page 33

    31 Combi HP ther mostatic mixer shower ...

  • HP COI 2180206H - page 34

    32 Combi HP ther mostatic mixer shower ...

  • HP COI 2180206H - page 35

    33 Combi HP ther mostatic mixer shower ...

  • HP COI 2180206H - page 36

    T riton Showers T riton Road Nuneaton W arwickshire CV11 4NR T riton is a division of Norcr os Group (Holdings) Limited TRITON reserve the right to change product specification without prior notice. E&OA. © TRITON SHOWERS 2008 Service Policy In t he e ve nt of a c om pl ai nt oc cu rr in g, t he fo ll ow in g pr oc ed ur e sh oul d be f ol lo ...

メーカー HP カテゴリー Plumbing Product

HP COI 2180206Hのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- COI 2180206Hの取扱説明書
- HPの製品カード
- パンフレット
- またはHP COI 2180206Hの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、HP COI 2180206Hの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、HP COI 2180206Hの取り付け説明書、サービスマニュアル、簡易説明書、またはHP COI 2180206Hのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、HP COI 2180206Hの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

HP COI 2180206Hデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHP COI 2180206Hを使用するのを助ける技術的文書のことです。説明書は通常、全てのHP COI 2180206Hユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

HPの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. HP COI 2180206Hの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHP COI 2180206Hの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。HP COI 2180206Hに関してこのドキュメントで見つけることができる全てのヒントの目次
3. HP COI 2180206Hデバイスの基本機能を使うにあたってのヒント。 HP COI 2180206Hのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。HP COI 2180206Hに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHP COI 2180206Hのメーカー/サービスへの連絡先に関する情報。

HP COI 2180206Hについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHP COI 2180206Hの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHP COI 2180206Hで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)