Miller Electric DB1812Rの取扱説明書

20ページ 0.43 mb
ダウンロード

ページに移動 of 20

Summary
  • Miller Electric DB1812R - page 1

    Visit our website at www.MillerWelds.com Processes Description TIG T orch OM-1603 199 528C 1/2005 TIG (GT A W ) W elding DB1812R And DB1825R Diamondback Series GT A W T orches ESP AÑOL FRANÇAIS ENGLISH ...

  • Miller Electric DB1812R - page 2

    T ABLE OF CONTENTS SECTION 1 −SAFETY PRECAUTIONS FOR GT A W T ORCHES − READ BEFORE USING 1 . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. GT A W T orch Hazards 1 . . . . . . . . . . . . . . . . . ...

  • Miller Electric DB1812R - page 3

    ENGLISH OM-1603 Page 1 SECTION 1 −SAFETY PRECAUTIONS FOR GT A W TORCHES − READ BEFORE USING SR6_1/00 1-1. Symbol Usage Means W arning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. This group of symbols means Warning! W atch Out! Possible ELECTRIC SHOCK and HOT P AR TS hazard ...

  • Miller Electric DB1812R - page 4

    OM-1603 Page 2 EMF INFORMA TION Considerations About W elding And The Ef fects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However , after examining more than 500 studies spanning 17 years of ...

  • Miller Electric DB1812R - page 5

    ENGLISH OM-1603 Page 3 SECTION 2 − SPECIFICA TIONS 2-1. Specifications Model DB1812R DB1825R Ampere Rating 350 Amps W/Argon Gas @ 100% Duty Cycle DCEN, ACHF Cooling Method W ater Cooling Requirements 1.1 quart/minute (1.0 liter/minute) T ungsten Size .020 Thru 5/32 in (0.5 Thru 4.0 mm) Cable Options 12-1/2 ft (3.8 m) One-Piece High−Flex 25 ft ( ...

  • Miller Electric DB1812R - page 6

    OM-1603 Page 4 SECTION 3 − INST ALLA TION 3-1. Required T orch Parts And T orch Assembly Ref. 802 676 Assembling T orch Parts 8 7 5 4 3 6 1 2 13 14 15 10 12 11 1 Cup 2 Collet Body 3 Heat Shield 4 Backcap Insulator 5 Collet 6 O-Ring 7 Backcap 8 T orch Body 9 Handle 10 Power Cable 1 1 W ater Hose 12 Gas Hose 13 Power Cable Adapter 14 International ...

  • Miller Electric DB1812R - page 7

    ENGLISH OM-1603 Page 5 3-3. Connecting T orch A. Connecting T orch When Using A Freestanding Coolant System  T urn Off welding power source and cooling system power before in- stalling torch. 1 W elding Power Source 2 Regulator/Flowmeter 3 Gas Cylinder 4 Gas Hose (Customer Supplied) Obtain correct length with 5/8-18 right-hand fittings. 5 T orch ...

  • Miller Electric DB1812R - page 8

    OM-1603 Page 6 B. Connecting T orch T o A Dynasty t 300 DX Or Maxstar  300 DX TIGRunner t Unit 803 31 1 T ools Needed: 5/8, 7/8, 1-1/8 in 2 3 1 10 5 6 8 11 4 7 9 12  T urn Off welding power source power before installing torch. 1 Gas Hose With 5/8-18 Right- Hand Fittings (Customer Sup- plied) Connections: 2 Regulator/Flowmeter 3 Gas Cylinder ...

  • Miller Electric DB1812R - page 9

    ENGLISH OM-1603 Page 7 SECTION 4 − MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance  Disconnect torch before maintaining. 40 Hours Replace unreadable labels. Repair or replace cracked weld cable. Clean and tighten weld terminals. Replace cracked parts T orch Body T orch Cable 4-2. T roubleshooting Before using troubleshooting table, ...

  • Miller Electric DB1812R - page 10

    OM-1603 Page 8 T rouble Remedy W andering arc Shield weld zone from drafts. Reduce gas flow rate. Select proper size and type tungsten. Properly prepare tungsten according to Section 5. When using AC, check welding power source High Frequency control setting, and increase setting if nec- essary . Y ellow powder or smoke on cup. Use proper type shie ...

  • Miller Electric DB1812R - page 11

    ENGLISH OM-1603 Page 9 SECTION 5 − SELECTING AND PREP ARING TUNGSTEN ELECTRODE FOR DC OR AC WELDING ac/dc_gtaw 2/2004  Whenever possible and practical, use DC weld output instead of AC weld output. 5-1. Selecting T ungsten Electrode ( Wear Clean gloves T o Prevent Contamination Of T ungsten ) Amperage Range - Gas T ype ♦ - Polarity Electrode ...

  • Miller Electric DB1812R - page 12

    OM-1603 Page 10 5-2. Preparing T ungsten Electrode For W elding  Grinding the tungsten electrode produces dust and flying sparks which can cause injury and start fires. Use local exhaust (forced ventilation) at the grinder or wear an approved respirator . Read MSDS for safety infor- mation. Consider using tungsten containing ceria, lanthana, or ...

  • Miller Electric DB1812R - page 13

    ENGLISH OM-1603 Page 1 1 6 -2. T orch Movement During Welding ST-162 002-B T ungsten Without Filler Rod T ungsten With Filler Rod Form pool Tilt torch Move torch to front of pool. Repeat process. 75 ° 75 ° W elding direction Form pool Tilt torch Add filler metal Move torch to front of pool. Repeat process. Remove rod W elding direction 15 ° 6-3. ...

  • Miller Electric DB1812R - page 14

    OM-1603 Page 12 SECTION 7 − P ARTS LIST Ref. 802 676-A 21 17 16 18 20 19 15 4 3 2 1 8 7 6 5 12 9 13 14 11 10 Figure 7-1. Complete T orch Assembly ...

  • Miller Electric DB1812R - page 15

    ENGLISH OM-1603 Page 13 Description Quantity Model No. Stock No. Item No. Model Figure 7-1. Complete T orch Assembly DB1825R DB1812R 1 57Y02 BACK CAP , long (consisting of) 1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ♦ 57Y04 BACK CAP , button 1 1 . . . . . . . . . . . . . ...

  • Miller Electric DB1812R - page 16

    OM-1603 Page 14 Description Quantity Model No. Stock No. Item No. Model Figure 7-1. Complete T orch Assembly (continued) DB1825R DB1812R 21 ♦ 198 314 HOSE, water side adapter international style (included w/190 219) 1 1 . . . . . . . . . . . . . . . . . . . . . . ♦ AK3C ACCESSORY KIT (included in DTP kit) 1 . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric DB1812R - page 17

    ENGLISH Notes ...

  • Miller Electric DB1812R - page 18

    Notes ...

  • Miller Electric DB1812R - page 19

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 1/05 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise o ...

  • Miller Electric DB1812R - page 20

    PRINTED IN USA  2005 Miller Electric Mfg. Co. 1/05 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Company 1635 W es t Spenc er S treet Applet on, W I 5 4914 USA International He adquarters− USA USA Phone: 920-735-4505 Aut o-At tended USA & C anada F A X: 920-735-4134 Int ernational F A X : 9 20-735-4125 European Headqua rt ers − U ...

メーカー Miller Electric カテゴリー Welder

Miller Electric DB1812Rのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DB1812Rの取扱説明書
- Miller Electricの製品カード
- パンフレット
- またはMiller Electric DB1812Rの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miller Electric DB1812Rの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miller Electric DB1812Rの取り付け説明書、サービスマニュアル、簡易説明書、またはMiller Electric DB1812Rのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miller Electric DB1812Rの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Miller Electric DB1812Rデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiller Electric DB1812Rを使用するのを助ける技術的文書のことです。説明書は通常、全てのMiller Electric DB1812Rユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Miller Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miller Electric DB1812Rの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiller Electric DB1812Rの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miller Electric DB1812Rに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miller Electric DB1812Rデバイスの基本機能を使うにあたってのヒント。 Miller Electric DB1812Rのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miller Electric DB1812Rに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiller Electric DB1812Rのメーカー/サービスへの連絡先に関する情報。

Miller Electric DB1812Rについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiller Electric DB1812Rの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiller Electric DB1812Rで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください