Friedrich CP18N30の取扱説明書

28ページ 0.96 mb
ダウンロード

ページに移動 of 28

Summary
  • Friedrich CP18N30 - page 1

    Ser vi ce & P ar ts Manu al 200 7 Compact Programmable Models CP14N10 CP18N30 CP24N30 CP-14-18-24-Svc-Prts-07 (3-07) ...

  • Friedrich CP18N30 - page 2

    2 T ab le o f Co n t en ts Per formanc e Data .............................................................................................................. .......................................................... 3 Outer Comp onent Identi fi cation ................................................................................................. ...

  • Friedrich CP18N30 - page 3

    3 Model CP14N10 CP18N30 CP24N30 Function COOLING COOLING COOLING Rated V oltage 1 15V ~ 230/208V~ 230/208V~ Rated Frequency 60Hz 60Hz 60Hz T otal Capacity (Btu/h) 14000 18000/17600 23500/23100 Power Input (W) 1430 1850/1810 2740/2710 Rated Input (W) 1540 2478 3538 Rated Current (A) 15 12.57 18.09 Air Flow V olume (CFM) (H) 458.8 458.8 617.6 Dehumid ...

  • Friedrich CP18N30 - page 4

    4 Out er Compo ne nt Ide n ti fi ca ti on Models : CP1 4N 1 0 , CP 1 8N3 0, CP2 4N30 Cabinet Air inlet louver F ront grille Pow e r co r d Control panel co ver F ront intake grille Air filter (behind front intake grille) ...

  • Friedrich CP18N30 - page 5

    5 Installat ion D imensions Models : CP1 4N 1 0 , CP 1 8N30, CP24 N30 (Top View) Fence / obstruction Over 2' Over 1' Over 1' Wall Or window (Front View) (Side View) Ceiling Over 1' Over 1' 25.98" 16.85" Less than 8.66" Over 2' ...

  • Friedrich CP18N30 - page 6

    6 CP24N30 CP18N30 / CP14N10 Wirin g Dia gram s ...

  • Friedrich CP18N30 - page 7

    7 F unct ional C omponent De fi niti ons MEC HANIC AL C OMPONEN TS Ve nt d o o r A l l o w s i n t r o d u c t i o n o f f r esh air into the ro om and/or exhausts stale r oom air outsi de ( on select mo dels. ) Plenum assembly D i f f u s e r w i t h d i r e c t i o n a l l o u v e r s u s e d t o d i r e c t the c onditione d air fl ow . Blower ...

  • Friedrich CP18N30 - page 8

    8 In the c ase of the c apillar y tube thi s is acc omplished (by design ) throug h size ( and length ) of device, and th e pressure di f ference present ac ross t he device. Since t he evaporato r c oil is under a l ower pre ssur e (d ue to the sucti on create d by the comp ress or) than the liquid line, the liqui d refr igerant leaves the m eteri ...

  • Friedrich CP18N30 - page 9

    9 EQUIP MENT RE QUIRED 1. Vo l t m e t e r 2. Ammeter 3. Ohmmeter 4. E.P . A . A pproved Ref riger ant Rec overy S ystem. 5. V acuum Pump (capable of 20 0 mic rons or le ss vacuum. ) 6. Acetylene Welder 7 . Elec troni c Halo gen Leak Detec tor (G.E . T yp e H - 6 or equivalen t. ) 8. Acc urate refri gerant char ge measurin g device such as: a. Bala ...

  • Friedrich CP18N30 - page 10

    10 NOTE : I n o r d e r t o a c c e s s t h e s e a l e d sy s t e m i t w i l l b e n e c e s s a r y t o i n s t a l l S c h r a d e r t y p e fi t tings to the proce ss tubes on the discharge and suct ion of the c ompress or . Proper refr igerant recovery proc edures need to be adhered t o as outlined in EP A R egulations. THIS SHO ULD ON L Y B ...

  • Friedrich CP18N30 - page 11

    11 A n u n d e r c h a r g e d s y s t e m w i l l r e s u l t i n p o o r p e r f o r m a n c e ( l o w pres sures, etc. ) in both the heatin g and co oling cycl e. Whenever you ser vice a unit wit h an under charge of refrigera nt, always suspect a le ak. The leak must be repair ed before chargin g the un it. T o c heck for an under charged syste ...

  • Friedrich CP18N30 - page 12

    12 RESTRICTED REFRIGERANT SYSTEM A quick c he c k for either c ondit ion begins at t he evaporator . W ith a par tial re stric tion, t here may be gurgling soun ds at the meterin g device entr ance to the evapor ator . The evaporato r in a par tial restr ict ion c ould be par tiall y froste d or have an ice ball clo se to the entranc e of the meter ...

  • Friedrich CP18N30 - page 13

    13 Problem Possible Cause Action Compressor does not run Low voltage Check voltage at compressor . 1 15V & 230V units will operate at 10% voltage variance T -stat not set cold enough or inoperative Set t-stat to coldest position. T est t-stat & replace if inoperative Compressor hums but cuts off on B10 overload Hard start compressor . Direc ...

  • Friedrich CP18N30 - page 14

    14 Problem Possible Cause Action Unit does not run Fuse blown or circuit tripped Replace fuse, reset breaker . If repeats, check fuse or breaker size. Check for shorts in unit wiring & components Power cord not plugged in Plug it in System switch in "OFF" position Set switch correctly Inoperative system switch T est for continuity in ...

  • Friedrich CP18N30 - page 15

    15 Problem Possible Cause Action Compressor runs for short periods only . Cycles on overload Overload inoperative. Opens too soon Check operation of unit. Replace overload if system operation is satisfactory Compressor restarted before system pressures equalized Allow a minimum of 2 minutes to allow pressures to equalize before attempting to restar ...

  • Friedrich CP18N30 - page 16

    16 Problem Possible Cause Action W ater "spitting" into room Sublimation: When unconditioned saturated, outside air mixes with conditioned air , condensation forms on the cooler surfaces Ensure that foam gaskets are installed in between window panes & in between the unit & the sleeve. Also, ensure that fresh air/exhaust vents (on ...

  • Friedrich CP18N30 - page 17

    17 Problem Possible Cause Action Room temperature uneven (Heating cycle) Heat anticipator (resistor) shorted (on applicable models) Disconnect power to unit. Remove resistor from t- stat bulb block. Plus in unit & allow to operate. Feel resistor for heat. If not heat, replace resistor Wide differential - partial loss of t-stat bulb charge Repla ...

  • Friedrich CP18N30 - page 18

    18 Problem Possible Cause Action Unit cools when heat is called for Incorrect wiring Refer to applicable wiring diagram Defective solenoid coil Check for continuity of coil Reversing valve fails to shift Block condenser coil & switch unit to cooling. Allow pressure to build up in system, then switch to heating. If valve fails to shift, replace ...

  • Friedrich CP18N30 - page 19

    19 Com pon en ts Model CP 1 4N 1 0 ...

  • Friedrich CP18N30 - page 20

    20 No Description Qty Friedrich Part# Code 1 Supporter Assy 1 67700200 2 Screw ST4.2X13 7 67700154 3 Window locking bracket 2 677001 13 4 Screw 4X20 6 67700151 5 Seal strip 1 1 67700128 6 Seal strip 2 1 67700129 7 Curtain Assemby Left and Right 1 67700201 8 Right Curtain 1 67700202 9 Left Curtain 1 67700203 10 Cabinet Assy 1 67700204 1 1 Screw ST4. ...

  • Friedrich CP18N30 - page 21

    21 No Description Qty Friedrich Part# Code 37 Clapboard of Snail Shell 1 67700108 38 Base Plate of Air Flue 1 67700106 39 Evaporator Assy 1 67700103 40 Sensor Holder 1 67700213 41 Compressor 44B124HXCEF 1 67700214 42 Overload Protector 1 67700215 43 Compressor Gasket 3 67700216 44 Nut with washer M8 3 67700156 45 Capillary Assy 1 67700217 46 Water ...

  • Friedrich CP18N30 - page 22

    22 No Description Qty Friedrich Part# Code 1 Supporter Assy 1 67700132 2 Self-threading Screw ST4.2x22 7 67700154 3 Window Locking Bracket 2 677001 13 4 Screw 4X20 6 67700151 5 Seal Strip 1 1 67700128 6 Seal Strip 2 1 67700129 7 Curtain Assemby Left and Right 1 67700166 8 Right Curtain 1 67700168 9 Left Curtain 1 67700167 10 Cabinet Assy 1 677001 1 ...

  • Friedrich CP18N30 - page 23

    23 No Description Qty Friedrich Part# Code 36 Blower Wheel 1 677001 16 37 Front Clapboard of Snail Shell 1 67700108 38 Base Plate of Air Flue 1 67700106 39 Evaporator Assy 1 67700103 40 Insert Block 2 67700141 41 Compressor 2K25S236AHF 1 67700101 42 Overload Protector 1 67700102 43 Compressor Gasket AD7070815 3 67700161 44 Nut with W asher M8 3 677 ...

  • Friedrich CP18N30 - page 24

    24 Com pon en ts Model CP2 4N30 ...

  • Friedrich CP18N30 - page 25

    25 No Description Qty Friedrich Part# Code 1 Supporter Assy 1 67700200 2 Screw ST4.2X13 7 67700154 3 Window locking bracket 2 677001 13 4 Screw 4X20 6 67700151 5 Seal strip 1 1 67700128 6 Seal strip 2 1 67700129 7 L T & R T Curtain Assembly 1 67700201 8 Right Curtain 1 67700202 9 Left Curtain 1 67700203 10 Cabinet Assy 1 67700238 1 1 Screw ST4. ...

  • Friedrich CP18N30 - page 26

    26 No Description Qty Friedrich Part# Code 38 Base Plate of Air Flue 1 67700106 39 Evaporator Assy 1 67700103 40 Sensor Holder 1 67700213 41 Compressor 44B124HXCEF 1 67700244 42 Overload Protector 1 67700215 43 Compressor Gasket 3 67700216 44 Nut with washer M8 3 67700156 45 Capillary Assy 1 67700245 46 Water T ray 1 67700131 47 Capacitor 15uF/300V ...

  • Friedrich CP18N30 - page 27

    Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR A NY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, ...

  • Friedrich CP18N30 - page 28

    CP-14-18-24-Svc-Prts-07 (3-07) F r iedrich Air Condition ing Co. Post Of f ice Box 15 4 0 • San Ant onio , T exa s 782 9 5 - 15 4 0 420 0 N. Pan A m Expr es sw ay • San Anto ni o, T exa s 7821 8 -5212 (210) 357 - 4 4 0 0 • F A X (210) 357 - 4 4 8 0 w w w. frie drich .com Printe d in th e U .S.A. ...

メーカー Friedrich カテゴリー Clothes Dryer

Friedrich CP18N30のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CP18N30の取扱説明書
- Friedrichの製品カード
- パンフレット
- またはFriedrich CP18N30の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Friedrich CP18N30の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Friedrich CP18N30の取り付け説明書、サービスマニュアル、簡易説明書、またはFriedrich CP18N30のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Friedrich CP18N30の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Friedrich CP18N30デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFriedrich CP18N30を使用するのを助ける技術的文書のことです。説明書は通常、全てのFriedrich CP18N30ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Friedrichの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Friedrich CP18N30の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFriedrich CP18N30の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Friedrich CP18N30に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Friedrich CP18N30デバイスの基本機能を使うにあたってのヒント。 Friedrich CP18N30のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Friedrich CP18N30に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFriedrich CP18N30のメーカー/サービスへの連絡先に関する情報。

Friedrich CP18N30についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFriedrich CP18N30の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFriedrich CP18N30で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください