    Inst allation and Operatio n Smart- UPS ® SUA1000- BR/SUA1500 -BR 120 V AC Eng lish ...

  • APC SUA1000-BR - page 2

    This manu al and th e safet y guide are avai labl e in Englis h on th e enclos ed CD and the APC W eb sit e, www .ap c.com . Este man ual e o g uia d e se guranç a est ão d isponíve is e m p ortugu ês no CD i nclus o e n o w ebsite da A PC, www .apc .com. ...

  • APC SUA1000-BR - page 3

    1 I ntroduct ion Th e AP C ® by Sch n ei d er Elect r i c Smar t - UPS ® is a hig h pe r fo rmance u ninterruptib le pow er supply (UP S) . It pr ovi d es pr ot e ct i on for el ect r on i c eq ui p m en t fr om ut i li t y po wer bl a ck ou t s , br own ou t s , sa g s , and surge s; smal l utility fluctuations a n d l ar ge d isturba n ces . T ...

  • APC SUA1000-BR - page 4

    2 Conne cti ng Eq uipme nt and P ower to the UP S S M ART -UPS R E AR P ANEL 1. Pl ug in th e battery connector n . 2. Conn ect equ i pmen t to th e UPS. No te : D o no t con nect a las er print er to the UP S. A las er printer d raws si gnificantly m ore po wer than other typ e s of equ ipm e nt and may o verload the UPS . 3. Add an y opti on al a ...

  • APC SUA1000-BR - page 5

    3 B ASIC C ONN ECT ORS Seria l P ort USB Port Pow er man a gem en t soft war e and int er face k i t s can be used w ith t h e U PS. U se o nly in terf ac e ki ts s u pp lied o r app rov ed by APC. Us e the AP C s u pplied ca ble to con nect to th e S eria l Po rt. DO N OT u se a sta nda rd seria l inte rfa ce ca ble sin ce it is inco m patib le w ...

  • APC SUA1000-BR - page 6

    4 On Ba tte ry Wh en th e on bat te r y pow e r LED is lit the UP S is supply in g b att e r y pow er t o t h e c onnected e quipme nt. Whe n o n ba ttery , the U P S so un ds an alar m— four beep s e ver y 30 secon d s. Ove rload The LED il lum inate s a nd the U PS e mits a s usta i n ed al arm to n e w h e n an o v erlo ad co n ditio n oc cu r ...

  • APC SUA1000-BR - page 7

    5 3: U SER C ON FI GURAB LE I TEM S N OTE : S ETTINGS ARE M A D E THROUG H SUPPLIED P OWE R C HUTE SOFTWA RE OR OP TIONA L S MA R T S LOT A CCESS O RY CA RDS . F UNC TI ON F ACTORY D EFAUL T U SER S ELE CT ABL E C HO ICE S D ESCRI PT ION A uto m atic S elf -T est Ev ery 14 d ay s (336 ho urs) E v e r y 7 d a ys (168 ho urs), On Sta rtu p On l y, No ...

  • APC SUA1000-BR - page 8

    6 N OTE : S ET TIN G S AR E M ADE TH RO UG H SU P PLIED P OWER C HUT E SOFTWA RE OR OPTI O N A L S MA R T S LO T A CCESS O RY CA RDS . F UNC TI ON F ACTORY D EFAUL T U SER S ELE CT ABL E C HO ICE S D ESCRI PT ION Shutdown Delay 90 seco nds 0, 90, 180, 270 , 360, 450, 540, 6 30 sec onds Sets the int erv al be tw een th e time wh en the UPS rec eiv e ...

  • APC SUA1000-BR - page 9

    7 4: S TORA G E , M AINT E N AN C E , AND T RAN SPORTIN G Storage Sto r e t he U PS co ve red a nd p os itione d as fo r pro pe r f unc tio ning , i n a co o l, dry locatio n, w ith t he b a t- ter i es full y ch ar g ed. At - 1 5 t o + 3 0 ° C ( +5 to + 8 6 ° F ), ch ar ge th e UPS bat t ery ever y six m on th s. At +30 to +45 ° C ( +86 to + 11 ...

  • APC SUA1000-BR - page 10

    8 1500VA Model Step 3 Pu ll t h e b atte r y mo dule ou t of th e co mpa rtmen t un t il th e ba ck of th e modu l e i s f l u sh with th e out er ed g es of t h e UPS . Di scon n ect th e ba tt er y c onn ect or . 1000VA Model Ste p 3 Di scon n ect th e ba tt er y cable t er min al s befor e r e m ovi n g th e ba t t er y mod u l e fr om th e UPS ...

  • APC SUA1000-BR - page 11

    9 R EPLACI NG THE B ATTERY M ODULE To r epla ce th e batt er y m odu l e, rever s e th e dir ect i on s above f or Remo ving the Front Be z e l and Battery Mo dule . Disconnec ting th e Batter y for Tr ansport 1. Sh ut down and d is conn ect an y eq ui p men t att a ched t o th e UPS. 2. Shut dow n and disc onnec t the UP S from ut i lity powe r . ...

  • APC SUA1000-BR - page 12

    10 5: T ROUBLES HOOT IN G Use t h e char t belo w to sol ve min or Smar t- UPS in s ta lla ti on an d oper at i on pr oblem s. Refer t o th e AP C We b s ite, www. a p c . c om , for a s si stan ce wi th com pl ex UPS pr oblem s. P ROBLE M AND P OSSI BL E C AU S E S OLU T ION UPS WILL NOT TURN ON Battery not co nnected prop- erly . Ch e ck th at t ...

  • APC SUA1000-BR - page 13

    11 P ROBLE M AND P OSSI BL E C AU S E S OLU T ION T HE O V ERL OAD LED IS LIT A ND THE UPS EMI T S A SU S T AIN E D AL AR M TO N E Th e U PS i s ove r l oa d e d. The co nnected equi pmen t exceed s the spec ifi ed “max i mum load” as defi ned i n Spe cificat i o ns at th e APC w e b si te , www.a pc. com . Th e al a r m re ma in s on u nt i l ...

  • APC SUA1000-BR - page 14

    12 P ROBLE M AND P OSSI BL E C AU S E S OLUTI O N UTILITY CIRCUIT BREAKER TRI PS Util it y c i r cui t bre a ker trip s dur ing no r mal o pera t ion. Reduc e the load o n t he U PS by unplug ging equipmen t and rese t ting t he circ ui t b reaker (on t he bac k of UPS ) by pressing the plung er in. UPS OPER ATES ON B ATTER Y ALTH OU GH NO RM AL L ...

  • APC SUA1000-BR - page 15

    13 Ser vice If the uni t req ui res se r v ice , do no t retu rn it to t he de ale r . F o llow th es e s tep s: 1. Re vi e w t h e Troubleshoo ting se c tion o f the man ual to elim ina te c ommo n pro b lems . 2. If the prob lem persists, co ntact AP C Custo mer Suppo rt throu gh the APC We b site, www.a pc.c om . a. No te th e mo del numb er a n ...

  • APC SUA1000-BR - page 16

    14 6: R AD I O F REQ UENCY W AR N I NG S AND W AR R ANT Y This de v ice comp lies w ith FCC Par t 15 Clas s A r eq ui reme nt s. Op e r atio n is sub j ect to the fo llow in g tw o conditio ns: ( 1) t his dev ice may n ot c aus e harmf ul inte rfe re n ce and (2) t his de v ice must a ccept an y in t er fer ence r ecei ved, in cl u din g int er fer ...

  • APC SUA1000-BR - page 17

    15 REME DY FOR ANY BRE ACH OF SUCH W ARRANTIES. APC WARRANTIE S RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY T H IRD PARTIES. IN NO EV EN T SH AL L AP C, IT S OF F ICE RS, D I RE CT O RS, A FF IL I AT ES O R EM PL OY EE S B E LI AB L E FO R ANY FO RM O F IN DI RE CT, S PE C IAL, CO NSE Q UE NT IAL OR P UN IT I VE DAMA GES, ARISIN G OUT OF THE ...

  • APC SUA1000-BR - page 18

    12/20 09 990- 3828 ...

メーカー APC カテゴリー Uninterruptible power supply (

APC SUA1000-BRのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SUA1000-BRの取扱説明書
- APCの製品カード
- パンフレット
- またはAPC SUA1000-BRの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、APC SUA1000-BRの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、APC SUA1000-BRの取り付け説明書、サービスマニュアル、簡易説明書、またはAPC SUA1000-BRのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、APC SUA1000-BRの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

APC SUA1000-BRデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAPC SUA1000-BRを使用するのを助ける技術的文書のことです。説明書は通常、全てのAPC SUA1000-BRユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

APCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. APC SUA1000-BRの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAPC SUA1000-BRの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。APC SUA1000-BRに関してこのドキュメントで見つけることができる全てのヒントの目次
3. APC SUA1000-BRデバイスの基本機能を使うにあたってのヒント。 APC SUA1000-BRのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。APC SUA1000-BRに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAPC SUA1000-BRのメーカー/サービスへの連絡先に関する情報。

APC SUA1000-BRについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAPC SUA1000-BRの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAPC SUA1000-BRで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)