    TECHNICAL GUIDE AFFINITY MODELS: PC9*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONT AL MODULA TING FURNACES WITH ECM MOT OR NA TURA L GAS 60 - 120 MBH INPUT Due to continuous prod uc t improvement, specifications are subject to cha ng e witho ut notice. Visit u s on the web at www .york.com for th e most up-to-date techni cal informa ...

  • York PC9*DH - page 2

    246815-YTG-D-0108 2 Unitary Products Group Annual Fuel Utilizat ion Effi ciency (AFUE) numbers are determined in accordance with DOE T est procedures. Wire size and over current protection must comply wi th t he National Electri cal Code (NFP A-70-latest edition) and all local code s. The furnace shall b e installed so that the electrical compo nen ...

  • York PC9*DH - page 3

    246815-YTG-D-0108 Unitary Products Group 3 NOTES: 1. Airflow expressed in standard cubic fee t per minute (CFM). AIR FLOW DAT A HIGH / LOW SPEED COOLING AND HEA T PUMP CFM PC9B12N060DH1 1 PC9B12N080DH1 1 JUMPER SETTINGS CFM CFM High Low High Low COOL T ap ADJ T ap 1330 900 1310 890 A B 1 130 800 1 100 740 B B 1220 850 1220 830 A A 1040 730 1000 670 ...

  • York PC9*DH - page 4

    246815-YTG-D-0108 4 Unitary Products Group FIL TER PERFORMANCE The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance WITHOUT filters. T o determine the approximate blower per- formance of the system, apply th e filter drop value for the fil- ter being used or select an appropriate val ...

  • York PC9*DH - page 5

    246815-YTG-D-0108 Unitary Products Group 5 For additiona l connection diagrams for all UPG equipment refer to “Li ne V olt age System Wiring” document ava ilable on-line at www .upgnet.com in the Product Catalog Section. Thermostat Chart - AC 26A Two Stage Air Co nditione r – Variable Speed Modulating Furnace C 24 – Volt Comm on Y1 First St ...

  • York PC9*DH - page 6

    246815-YTG-D-0108 6 Unitary Products Group Thermostat Chart - AC 26B Two Stage Air Conditioner – Variable Speed Mod ulating Furnace TWO STAGE AIR CONDITIONER C 24 – Volt Comm on R 24 – Volt Hot Y1 First Stage Co mp ressor Y2 Second St age Compre ssor C 24 – Volt Comm on R 24 – Volt Hot Y1 Single Stag e Compressor VARIABLE SPEED MODULATING ...

  • York PC9*DH - page 7

    246815-YTG-D-0108 Unitary Products Group 7 Thermostat Chart - Optional Harness AC 26C Two Stage Air Co nditione r – Variable Speed Modulating Furnace TWO STAGE AIR CONDITIONER C 24 – Volt Comm on R 24 – Volt Hot Y1 First Stage Co mp ressor Y2 Second St age Compre ssor C 24 – Volt Comm on Y1 First Stage Co mp ressor L Malfunction Ligh t Y2 S ...

  • York PC9*DH - page 8

    246815-YTG-D-0108 8 Unitary Products Group Thermostat Chart - O Reversing Valve Energized in Cool C 24 – Volt Comm on R 24 – Volt Hot W1 OUT First Stage Heat W2 OUT Second Stage He at Y2 OUT Second Stage Comp ressor Y1 Single Stage Co mpressor X/L Malfunction Ligh t Y2 Second Stage Comp ressor W Auxiliary Hea t BS Bonnet Sensor BSG Bonnet Senso ...

  • York PC9*DH - page 9

    246815-YTG-D-0108 Unitary Products Group 9 Thermostat Chart - HP 28C Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation) O Reversing Valve Energized in Cool C 24 – Volt Comm on R 24 – Volt Hot W1 OUT First Stage Heat W2 OUT Second Stage He at Y2 OUT Second Stage Comp ressor Y1 Single Stage Compressor X/L Mal ...

  • York PC9*DH - page 10

    246815-YTG-D-0108 10 Unitary Products Group ACCESSORIES PROP ANE (LP) CONVERSION KIT - 1NP0680 - All units This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. Conversions must be made by qualified distributor or dealer personnel. CONCENTRIC VENT TERMINA T ION - 1CT0302 (2") 1CT0303 (3") C ...

  • York PC9*DH - page 11

    246815-YTG-D-0108 Unitary Products Group 11 NOTES ...

  • York PC9*DH - page 12

    Subject to change without notice. Printe d in U.S.A. 246815-YTG-D-0108 Copyright © by Unitary Products Gr oup. 2008. All rights reserved. Supersedes: 246815-YTG-C-0606 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...

メーカー York カテゴリー Radio

York PC9*DHのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PC9*DHの取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork PC9*DHの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York PC9*DHの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York PC9*DHの取り付け説明書、サービスマニュアル、簡易説明書、またはYork PC9*DHのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York PC9*DHの製品を使用するにあたって最も人気のある説明書を閲覧できます。

York PC9*DHデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork PC9*DHを使用するのを助ける技術的文書のことです。説明書は通常、全てのYork PC9*DHユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York PC9*DHの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork PC9*DHの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York PC9*DHに関してこのドキュメントで見つけることができる全てのヒントの目次
3. York PC9*DHデバイスの基本機能を使うにあたってのヒント。 York PC9*DHのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York PC9*DHに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork PC9*DHのメーカー/サービスへの連絡先に関する情報。

York PC9*DHについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork PC9*DHの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork PC9*DHで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)