Powerware FCC 15の取扱説明書

32ページ 0.48 mb
ダウンロード

ページに移動 of 32

Summary
  • Powerware FCC 15 - page 1

    Powerware Modbus Card User’s Guide ®® ...

  • Powerware FCC 15 - page 2

    Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with th e limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm ent. This equipment generates, ...

  • Powerware FCC 15 - page 3

    EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com i Table of Contents 1 Introduction 1 ......................................................... 2 Installing the Modbus Card 3 ............................................. Inspecting the Equipment 3 ................................................................ F ...

  • Powerware FCC 15 - page 4

    TABLE OF CONTENTS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com ii ...

  • Powerware FCC 15 - page 5

    EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 1 Chapter 1 Introduction The Eaton ® Powerware ® Modbus ® Card is an X - Slot ® connectivity device that allows you to continuously and reliably monitor the UPSs in your Building Management System (BMS). The card uses the Modbus protocol to integrate data from ...

  • Powerware FCC 15 - page 6

    INTRODUCTION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 2 RS-485 Network Power Meter PLC UPS with Modbus Card Ethernet Gateway Building Management Software Ethernet -270.6 -270.6 Figure 2. UPS Integrated with RS-485 Network ...

  • Powerware FCC 15 - page 7

    EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 3 Chapter 2 Installing the Modbus Card The Modbus Card is available: S as a separate card for use with UPSs that have an X - Slot S factory - installed in a Powerware Expansion Chassis Use the following sequence for installing the Modbus Card: 1. For four - wire ne ...

  • Powerware FCC 15 - page 8

    INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 4 Four-Wire Communication The factory - default setting for the Modbus Card is for two - wire communication. To change the default setting, adjust the jumpers on the Modbus Card. CAUTION To prevent electrostatic discharge (ESD), pl ace on ...

  • Powerware FCC 15 - page 9

    INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 5 3. Change the J9 and J10 jumpers to the desired setting as shown in Figure 4. 1 1 J11 23456 ON S2 J7 J8 J10 J9 J9 J10 Four-Wire 1 1 J9 J10 Two-Wire (Default) 1 1 Figure 4. Modbus Card Jumpers 4. Reinstall the Modbus Card into the Powerw ...

  • Powerware FCC 15 - page 10

    INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 6 Installing the Modbus Card into an X-Slot CAUTION To prevent electrostatic discharge (ESD), pl ace one hand on an unpainted metal surface such as the UPS rear panel. 1. Remove the X - Slot cover (or existing X - Slot module) on the UPS ...

  • Powerware FCC 15 - page 11

    EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 7 Chapter 3 Wiring the Modbus Card The Modbus Card provides an easy path for integrating a Powerware UPS into an RS - 485 Modbus network and also provides isolation of the communication between the UPS and the RS - 485 Modbus network. You can use the DB - 9 port or ...

  • Powerware FCC 15 - page 12

    WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 8 Four-Wire Networks The Modbus Card also supports four - wire, half - duplex, RS - 485 networks. Figure 7 shows a detailed view of four - wire connections using the Modbus Card terminal strip. Slave Device #1 Master Device Slave Device #2 *S ...

  • Powerware FCC 15 - page 13

    WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 9 For four-wire networks. All four RS -485 network signals including TxD(+), RxD(+), TxD(–), and RxD(–) must be connected to the terminal strip as illustrated in Table 1. Verify that the Modbus Card J9 and J10 jumpers are set to the four ...

  • Powerware FCC 15 - page 14

    WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 10 3 8 7 9 1 6 2 4 5 Figure 9. RS-485 DB-9 Pin Numbers Table 2. RS-485 DB-9 Pin Assignments Pin Number Modbus Card Signal Name RS-485 Network Signals Master Signal Name 1 RxD(+) TxD(+) 2 TxD(+) RxD(+) 3 Signal common Signal common 4 Reserved ...

  • Powerware FCC 15 - page 15

    WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 11 1 J11 S2 J7 J8 J10 J9 RxD(–) Pull Down (620 Ω) RxD Terminator (120 Ω) Four-Wire Two-Wire ON *OFF 12 34 5 6 TxD(–) Pull Down (620 Ω) TxD(+) Pull Up (620 Ω) TxD Terminator (120 Ω) RxD(+) Pull Up (620 Ω) *Factory-default = OFF ...

  • Powerware FCC 15 - page 16

    WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 12 RS-232 Modbus Port It is also possible to use the RS - 232 Modbus port for connecting to your network. 3 8 7 9 1 6 2 4 5 Figure 11. RS-232 DB-9 Pin Numbers Table 3. RS-232 DB-9 Pin Assignments Pin Number Function Direction from the Modbus ...

  • Powerware FCC 15 - page 17

    EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 13 Chapter 4 Modbus Card Configuration The Modbus Card has an RS - 232 configuration port that you can access with a terminal or a computer equipped with a terminal emulation program. To use the configuration screens for the Modbus Card, you need: S A serial commun ...

  • Powerware FCC 15 - page 18

    MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 14 2. Press [Enter]. The Configuration screen appears (see Figure 13). Powerware Modbus Card Version 1.00 (1-16-02) Current Configuration: Baud Rate: 9600 Slave Address: 29 ------------------------------------------------------------------ ...

  • Powerware FCC 15 - page 19

    MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 15 4. To configure the slave address, type AD followed by a space and node (1 through 247) and press [Enter]. The default is 29. This setting affects both RS - 232 and RS-485 Modbus connections. 5. To save and exit, type SA and press [Ente ...

  • Powerware FCC 15 - page 20

    MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 16 ...

  • Powerware FCC 15 - page 21

    EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 17 Chapter 5 Integrating the UPS Powerware provides a software tool named Modbus Profiler that creates a Modbus register map specifically for your Powerware UPS. Refer to the Master Modbus Register Map for a complete list of the Status, Alarm, and Meter data for al ...

  • Powerware FCC 15 - page 22

    INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 18 5. Run profiler from the command prompt or double - click profiler.exe from Microsoft Windows Explorer. By default, Modbus Profiler uses the communication port specified in the [Connection] section of the profiler.ini file. If profiler fails ...

  • Powerware FCC 15 - page 23

    INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 19 Unit Format Value Name Register 113 Rectifier Input Status 1 BOOL Status 114 Bypass Status 0 BOOL Status 115 Bypass Input Status 1 BOOL Status 116 Input Circuit Breaker Status (CB1) 1 BOOL Status 117 Battery Disconnect Status 1 BOOL Status 11 ...

  • Powerware FCC 15 - page 24

    INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 20 Unit Format Value Name Register 162 Building Alarm 2 1 BOOL Status 163 Building Alarm 1 0 BOOL Status 169 Output overload 0 BOOL Status 172 DC link over voltage 0 BOOL Status 173 DC link under voltage 0 BOOL Status 174 Rectifier failed 0 BOOL ...

  • Powerware FCC 15 - page 25

    INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 21 Table 5. Read Input Registers - Modbus Function Code 04 (Input Registers Start at 30000) Register Meter Name Scale Unit 1 OUTPUT VOLTS AB /10 Volts 2 OUTPUT VOLTS BC /10 Volts 3 OUTPUT VOLTS CA /10 Volts 4 INPUT VOLTS AB /10 Volts 5 INPUT VOL ...

  • Powerware FCC 15 - page 26

    INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 22 Unit Scale Meter Name Register 62 INVERTER VOLTS PHASE C /10 Volts 66 LOAD CURRENT PHASE A /10 Amps 67 LOAD CURRENT PHASE B /10 Amps 68 LOAD CURRENT PHASE C /10 Amps 69 LOAD CURRENT PHASE A BAR CHART /10 Amps 70 LOAD CURRENT PHASE B BAR CHART ...

  • Powerware FCC 15 - page 27

    EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 23 Chapter 6 Troubleshooting Problem Possible Cause Corrective Action The Modbus Profiler tool does not generate the f i l f i l The wrong communication port number was entered in the profiler comX command. Verify the correct port number on your computer that is co ...

  • Powerware FCC 15 - page 28

    TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 24 1 J11 2 13 4 5 6 ON S2 J7 J8 J10 J9 S2 Termination (Default ”OFF”) J11 Half Duplex Full-Duplex (Default) 1 1 J9 J10 Two-Wire (Default) 1 1 Two-Wire/Four-Wire J7 J8 DCE DCE/DTE (Default) 11 Figure 15. Modbus Card Default Jumper Settings ...

  • Powerware FCC 15 - page 29

    TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 25 Service and Support If you have any questions or problems with the Modbus Card, call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a Modbus Card technical representative. United States: 1-800-356-57 ...

  • Powerware FCC 15 - page 30

    TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 26 ...

  • Powerware FCC 15 - page 31

    ...

  • Powerware FCC 15 - page 32

    *164201376C* 164201376 C ...

メーカー Powerware カテゴリー Network Card

Powerware FCC 15のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FCC 15の取扱説明書
- Powerwareの製品カード
- パンフレット
- またはPowerware FCC 15の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Powerware FCC 15の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Powerware FCC 15の取り付け説明書、サービスマニュアル、簡易説明書、またはPowerware FCC 15のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Powerware FCC 15の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Powerware FCC 15デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPowerware FCC 15を使用するのを助ける技術的文書のことです。説明書は通常、全てのPowerware FCC 15ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Powerwareの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Powerware FCC 15の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPowerware FCC 15の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Powerware FCC 15に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Powerware FCC 15デバイスの基本機能を使うにあたってのヒント。 Powerware FCC 15のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Powerware FCC 15に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPowerware FCC 15のメーカー/サービスへの連絡先に関する情報。

Powerware FCC 15についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPowerware FCC 15の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPowerware FCC 15で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)