    990 -1060B 12/2005 APC Smart-UPS ® RT 1000/2000 VA 220/230/240 V AC Tower/ Rack Mount 2U Uninterr uptible Pow er Suppl y User Manual English ...

  • APC SURT2000XLI-1BNDL - page 2

    ...

  • APC SURT2000XLI-1BNDL - page 3

    1 990 -1060B 12/ 2005 1: S AF E T Y I NFORMA TION American Po wer Conversion Corporation (APC) is the leading national and internatio nal manufac- turer of state-of-the- art uninterrupt ible power su pplies, redundant switches, powe r manag ement soft- ware, an d related equipment. APC products protect hardw are, software, and data from the threat ...

  • APC SURT2000XLI-1BNDL - page 4

    990 -1060B 12/2005 2 • In order to maintain compliance with the EMC directive, output cords attached to the UPS should n ot exceed 10 meters in length. D EENERGIZING S AFE T Y • If the equ ip ment has an internal energy source (b attery), the output may be en er gized when the unit is not connected to an AC power ou tlet. • To deenergize pl u ...

  • APC SURT2000XLI-1BNDL - page 5

    3 990 -1060B 12/ 2005 2: I NS T A LLA TION U NPACKING Inspect the UPS upon receipt. A PC designed robust packag ing for your product. How e ver, accidents and damag e may occur during s hipment. Notify the carrier and dealer if there is damage. The packaging is rec yclable; save it for reu se or dispose of it properly . Check the packag e co ntents ...

  • APC SURT2000XLI-1BNDL - page 6

    990 -1060B 12/2005 4 I NSTALLA TIO N 1. A TTACH THE S UPP ORT F EET If the UPS is to be operated in To wer Configuration the suppor t feet must be attached for proper stabilit y. 1. Locate the two feet an d t he plastic bag con tain- ing the four screws pac ked with the UPS. 2. Gently la y the UPS on it s side a s shown. 3. Use the screws to attach ...

  • APC SURT2000XLI-1BNDL - page 7

    5 990 -1060B 12/ 2005 3. C ONNECT THE B ATTERY 1. To connect the battery , push the batter y conn ec- tor into the receptacle in the battery co mpart- ment. Press firmly to ensure a tight connection. You will hear a “snap” when the connector is seated properly . 2. Push the battery cables and white cord into the space with the battery connector ...

  • APC SURT2000XLI-1BNDL - page 8

    990 -1060B 12/2005 6 6. T URN ON THE UPS Make sure the battery is co nnected be fore turning on the U PS! P ress the button on the front panel to power up your UPS. This will power up connected equipment if that equipment is turned on. The UPS charges its batter y when it is connected to utility po wer. The battery char ges full y dur ing t he fi r ...

  • APC SURT2000XLI-1BNDL - page 9

    7 990 -1060B 12/ 2005 3: O PE R A T ION I NDICATORS AND C ONTROLS The UPS power con trol and operating indicators are located on the front display panel. The inpu t and output conn ectors are on the rear panel. F RONT P ANE L Fo r Pos i t io n O n l y | The ON and OFF buttons pow er the UPS and act as master controls for the conn ected equipment if ...

  • APC SURT2000XLI-1BNDL - page 10

    990 -1060B 12/2005 8 O PERATION Power On Press and release the button to supply po w er to the UPS and conn ected equipment. Cold Start When the UPS is off and there is no utility power, use the cold start feature to apply power to th e connected equipment fr om the UPS’s batter y. Cold start is not a normal condition. To cold start the unit, pus ...

  • APC SURT2000XLI-1BNDL - page 11

    9 990 -1060B 12/ 2005 U TILITY P OWER During normal operation, the UPS monitors the utility power and delivers po wer to the conn ected equip me nt. If your syste m is e xp erie nci ng exc essi ve p eri od s of hi gh or l o w volta ge, have a cer tifie d electrician check your facility for electrical problems. If the problem continues, contact the ...

  • APC SURT2000XLI-1BNDL - page 12

    990 -1060B 12/2005 10 B ATTERY P OWER If the utility power fails, the UPS can pro vide power to the connected equipment from its internal batteries for a finite period. The UPS sounds an alarm—four beeps every 30 secon ds—while operat- ing on battery. The alarm stops when the UPS returns to onli ne operation. On Battery When the On Battery indi ...

  • APC SURT2000XLI-1BNDL - page 13

    11 990-1 060B 12/20 05 R EAR P ANE L TVSS Ground Input Plug Computer Interface Port Fan External Battery Connector Port Outlets B ASIC C ONNE CTORS Computer Inter- face Port Power management sof t ware and interface k its can be used with the UPS. Use only interface ki ts su pplied or appro ved by APC. If used, conn ec t the interface cable to th e ...

  • APC SURT2000XLI-1BNDL - page 14

    990 -1060B 12/2005 12 O N B ATTERY O PERATION The UPS s witches to battery operation auto matically and an internal alarm sounds (periodic b eeps) if the utility power fails. Press t he ON button (front panel) to silence the UPS alar m until low batter y (for the cu rrent outage only). You can change the audible indicator if you are u sing Po werCh ...

  • APC SURT2000XLI-1BNDL - page 15

    13 990-1 060B 12/20 05 N OTE : S ETTING THESE ITEMS REQUIRES SOFTWARE , OPTION AL HA RDWARE , OR CONFIGURATION IN T ERM INAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Sync hronized Turn-on Delay 0 seconds 20, 60 , 120, 240 , 480, 720, 96 0 sec- onds The UPS will w ait the specified tim e after the retur n of utilit ...

  • APC SURT2000XLI-1BNDL - page 16

    990 -1060B 12/2005 14 4: T RANSPORT , M AINTENANCE , AND T ROUB LESHOOT ING T RANSPORTING YOUR UPS Alway s DISCONNECT THE B ATTERY before shipping in co mpliance with U.S. Departm e nt of Trans portation (DOT) regul ations . The battery may rem ai n in the UPS; it does not have to be removed. This require ment applies w hether the UPS is shi pped a ...

  • APC SURT2000XLI-1BNDL - page 17

    15 990-1 060B 12/20 05 R EPLACING THE B ATTERY P ACK This UPS has an easy to replace, h ot-s wappable battery pack. Replacement is a safe procedure, is o- lated from electrical hazards . You may leave the UPS and c onnected equipment on while replacing the battery. See your dealer or cont act APC for in formation on replacem ent batter y packs . Th ...

  • APC SURT2000XLI-1BNDL - page 18

    990 -1060B 12/2005 16 T ROUBLESHOOTING Use the chart belo w to solve minor UPS installation pro blems. Refer to the APC web site www.apc.com for assistance with complex UPS problems. P ROBLEM AND P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON ON bu tton no t pushe d. Pre ss the ON button o nce to powe r the UP S and the equipm ent. UPS not con ne ...

  • APC SURT2000XLI-1BNDL - page 19

    17 990-1 060B 12/20 05 S ERVICE 1. Revi e w the problem s discussed in t he Troubleshoot ing section of th is manual to eliminate com- mon probl ems. 2. Verify that no circuit break ers are tripped. A tripped circuit break er is the most common prob- lem. 3. If th e problem persists, call APC Cust o mer Servi ce or visit the APC w ebsite (www.apc.c ...

  • APC SURT2000XLI-1BNDL - page 20

    990 -1060B 12/2005 18 5: C ON T A CT , R EGUL A TORY , A ND W AR R AN T Y I NFOR MA TION C ONTACTING AP C Refer to the information pro vided at the APC Internet site: http:/ / www.apc.com/su pport R EGULATORY A GE NCY A PPROVALS N 3 94 B ME 61 D ECLARATION OF C ONF ORM ITY ...

  • APC SURT2000XLI-1BNDL - page 21

    19 990-1 060B 12/20 05 L IMITED W ARRA NTY American Power Conv ersion (APC) warrants its produ cts to be free from defects in materials an d workmansh ip for a period of tw o years from the dat e of purchase. Its obligation under t his warranty is limited to repairing or replacing, at its o wn sole option, any such defective products. T o obtain se ...

メーカー APC カテゴリー Uninterruptible power supply (

APC SURT2000XLI-1BNDLのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SURT2000XLI-1BNDLの取扱説明書
- APCの製品カード
- パンフレット
- またはAPC SURT2000XLI-1BNDLの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、APC SURT2000XLI-1BNDLの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、APC SURT2000XLI-1BNDLの取り付け説明書、サービスマニュアル、簡易説明書、またはAPC SURT2000XLI-1BNDLのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、APC SURT2000XLI-1BNDLの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

APC SURT2000XLI-1BNDLデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAPC SURT2000XLI-1BNDLを使用するのを助ける技術的文書のことです。説明書は通常、全てのAPC SURT2000XLI-1BNDLユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

APCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. APC SURT2000XLI-1BNDLの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAPC SURT2000XLI-1BNDLの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。APC SURT2000XLI-1BNDLに関してこのドキュメントで見つけることができる全てのヒントの目次
3. APC SURT2000XLI-1BNDLデバイスの基本機能を使うにあたってのヒント。 APC SURT2000XLI-1BNDLのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。APC SURT2000XLI-1BNDLに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAPC SURT2000XLI-1BNDLのメーカー/サービスへの連絡先に関する情報。

APC SURT2000XLI-1BNDLについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAPC SURT2000XLI-1BNDLの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAPC SURT2000XLI-1BNDLで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)