    AQ1000 / AQ2000 AL TERNA TING PRESSURE BUBBLE P AD AND PUMP SYSTEM USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. The latest version of this manual can be found online at www.grahameld.com. AQ1000-INS-LAB-RevD13 ...

  • Lumex Syatems AQ2000 - page 2

    2 AQ1000-INS-LAB-RevD13 CONTENTS INTRODUCTION ...................................................................................... 3 INTENDEDUSEOFTHISDEVICE ........................................................ 3 CONTRAINDICA TION ...................................................................... 3 DANGER ....... ...

  • Lumex Syatems AQ2000 - page 3

    AQ1000-INS-LAB-RevD13 3 INTRODUCTION Use this manual for setup and operation of the Lumex AQ1000 / AQ2000 Alternating Pr essur e Pad and Pump System. Read all instructions befor e using the pad and pump system. Save this manual for futur e r eference. INTENDED USE OF THIS DEVICE The intended use of the Alternating Pr essur e Pad and Pump System, ...

  • Lumex Syatems AQ2000 - page 4

    4 AQ1000-INS-LAB-RevD13  CAUTION:Indicatesapotentialhazardorunsafe practicethat,ifnotavoided,couldresultinminoror moderatepersonalinjury . s  NOTICE:Indicatesapotentialhazardorunsafepractice that,ifnotavoided,couldresultinproductorpr ...

  • Lumex Syatems AQ2000 - page 5

    AQ1000-INS-LAB-RevD13 5  W ARNING:Neveroperatethisproductif a) ithasadamagedcordorplug. b) itisnotworkingproperly . c) ithasbeendroppedordamaged. d) ithasbeendroppedintowater .  ReturntheproducttoyourGraham-Fieldauthorized? ...

  • Lumex Syatems AQ2000 - page 6

    6 AQ1000-INS-LAB-RevD13 EQUIPMENT SYMBOLS Attention! Consult accompanying documents (this manual) “BF”symbol: Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment Grounding terminal Class II (for UL only) Disposal of Electrical & Electronic Equipment (WEEE): Do not treat ...

  • Lumex Syatems AQ2000 - page 7

    AQ1000-INS-LAB-RevD13 7 PRODUCT DESCRIPTION B UBBLE P AD AND PUMP SY STEM bubble pad and pump system air tubes bubble pad pump PUMP pump (AQ2000 shown) front panel wire hangers fuses (220V only) air tube connectors ...

  • Lumex Syatems AQ2000 - page 8

    8 AQ1000-INS-LAB-RevD13 FRONT P ANEL AQ1000 AQ1000 pump front panel ON/OFF switch air tube connectors AQ2000 AQ2000 pump front panel ON/OFF switch pressur e control dial Fr ont panel pr essur e contr ol dial (AQ2000 only) : The pr essur e control dial contr ols the air pr essure output. T o incr ease pr essure, turn the dial clockwise. T o decre ...

  • Lumex Syatems AQ2000 - page 9

    AQ1000-INS-LAB-RevD13 9 INST ALLA TION UNP ACKING 1. Befor e unpacking, check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field authorized distributor . 2. Remove all loose packing fr om the carton. 3. Car efully r emove all components from the carton. 4. Inspect all component ...

  • Lumex Syatems AQ2000 - page 10

    10 AQ1000-INS-LAB-RevD13 5. Connect one end of the air tubes to the bubble pad: slide the ends of the air tubes over the connectors on the top of the foot end of the bubble pad. 6. Connect the other end of the air tubes to the pump connectors; ensur e that the ends of the air tubes ar e rmly tted over the bubble pad and pump connectors bef ...

  • Lumex Syatems AQ2000 - page 11

    AQ1000-INS-LAB-RevD13 11 OPERA TION 1. T urn the ON/OFF switch to the ON position. The pump will begin to deliver air into the bubble pad. 2. Replace all sheets, blankets, and pillows on the bed. Info: if the pressure level seems low , check for any leakage in the air tubes or bubble pad. Replace any damaged tubes. If necessar y , contact your G ...

  • Lumex Syatems AQ2000 - page 12

    12 AQ1000-INS-LAB-RevD13 MAINTENANCE CLEANING Perform the following cleaning pr ocedur es before use and as necessar y thereafter . Pump W ipe the pump with a clean, damp cloth and mild deter gent, and keep it away from dust. Air dr y . s  NOTICE:Donotusephenolicproductsorcorrosiveor powderedcleanserstoclea ...

  • Lumex Syatems AQ2000 - page 13

    AQ1000-INS-LAB-RevD13 13 Fuse replacement (220V system onl y) tool needed: small screwdriver 1. If you suspect a blown fuse, disconnect the plug fr om the wall outlet immediately . fuse location fuse fuse cover 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse locations ar e shown in pictur e above). 3. Insert a new fuse ...

  • Lumex Syatems AQ2000 - page 14

    14 AQ1000-INS-LAB-RevD13 SPECIFICA TIONS Model AQ1000 (Standard) AQ2000 (Delux e) P ow er Supply 120V : 120V AC, 60 Hz, 1A 220V : 230V AC, 50 Hz, 7W Fuse Rating 120V : N/A 220V : T1A, 250V Pressur e 1.9 psi (13.10 kPa) 1.0 - 2.0 psi (6.89-13.79 kPa) Air Output 120V : 4.5 LPM 120V : 4-5 LPM 220V : 5.0 LPM 220V : 5-6 LPM Cyc le Time 120V : 5 min. ...

  • Lumex Syatems AQ2000 - page 15

    AQ1000-INS-LAB-RevD13 15 WARRANTY GF Health Pr oducts, Inc. warrants the Lumex AQ1000 / AQ2000 Alternating Pr essur e Pad and Pump System for defects in workmanship and materials for the terms listed below . Pump: one year Pad: 90 days If a pr oduct is deemed to be under warranty , GF Health Pr oducts, Inc. shall pr ovide, at its option, (1) r e ...

  • Lumex Syatems AQ2000 - page 16

    GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 tel: 770-368-4700 fax: 770-368-2386 www .grahamfield.com © 2008 GF Health Products, Inc. ...

メーカー Lumex Syatems カテゴリー Marine Instruments

Lumex Syatems AQ2000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AQ2000の取扱説明書
- Lumex Syatemsの製品カード
- パンフレット
- またはLumex Syatems AQ2000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lumex Syatems AQ2000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lumex Syatems AQ2000の取り付け説明書、サービスマニュアル、簡易説明書、またはLumex Syatems AQ2000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lumex Syatems AQ2000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lumex Syatems AQ2000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLumex Syatems AQ2000を使用するのを助ける技術的文書のことです。説明書は通常、全てのLumex Syatems AQ2000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lumex Syatemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lumex Syatems AQ2000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLumex Syatems AQ2000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lumex Syatems AQ2000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lumex Syatems AQ2000デバイスの基本機能を使うにあたってのヒント。 Lumex Syatems AQ2000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lumex Syatems AQ2000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLumex Syatems AQ2000のメーカー/サービスへの連絡先に関する情報。

Lumex Syatems AQ2000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLumex Syatems AQ2000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLumex Syatems AQ2000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)