  • IBM 5U Rackmount Server Chassis YY-R5xx - page 1

    ZZ17-W2001-B 1 YY -W2xx Pedest al Server Chassis YY -R5xx 5U Rackmount Server Chassis Installation Guide 2005.04. V ersion B ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 2

    ZZ17-W2001-B 2 INDEX 1. Intr oduction 2. Hardwar e Packing List 3. System Installation 3.1.Chassis Open 3.2.Motherboard Installation 3.3.Add-on Card Installation 3.4.CD–ROM Drive/FDD Installation. 3.5.Fixed HDD Cage , HDD Installation 3.6.Instructions for Switches and LED Indicators on front panel 3.7.Instructions for cooling fan assembly 3.8.Rac ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 3

    ZZ17-W2001-B 3 1. INTRODUCTION YY -W2 series Server Chassis is designed in compliant with EEB3.0 specification (refer to www .ssiforum.or g ) and A TXV2.1 (refer to www .formfactors.org) Mother Board: z YY -W2 is designed for extended A TX (12"x13"), in compliant with A TX spec, CEB and EEB3.0 spec. z S t o r a g e : The chassis sup ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 4

    ZZ17-W2001-B 4 Thermal Solution: z One(1) 120x120mm Cooling Fan is installed, rear mounted z Options of two (2) 60*60*25mm , rear mounted. Switches and LED Indicators on front panel z Power Switch (Push Switch) z Reset Button (Push Switch) z Power On LED (Green) z HDD LED (Orange flash) z F AN ALARM (Red) z LAN LED (Green/Fl ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 5

    ZZ17-W2001-B 5 2. Hardware Packing List When you unpack your YY -W2 Server Chassis, check that all the items that you ordered are present in good condition. Review the inventory checklist below to be sure that the components and optional components that you ordered are included. If anything is missing or damage, contact your retailer as soon as pos ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 6

    ZZ17-W2001-B 6 3. System Installation 3.1 Chassis Open T o release two (2) screws on the rear side of chassis, pull the side cover with handle. 3.2 Motherboard Installation Check mounting holes of motherboard, to screw the standof fs required to chassis. Put the Motherboard into the chassis, than screw in for fixing. Next step is to plug the DC A T ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 7

    ZZ17-W2001-B 7 3.3 PCI Add-on Card Installation Remove the tail gate bracket, install PCI card into motherboard, and screw in bracket to rear window of chassis. The chassis could be optional required A Card Clamp Holder which is used to clamp the Add-on Card for avoiding any popping issue. T o remove The Clamp Holder first, install Add-on Cards as ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 8

    ZZ17-W2001-B 8 T o remove the front panel fist, the front panel is snap in chassis with hocks (or/and screw on by 4pcs screws), please screw of f the screws and pull the front panel forward. z T o remove the metal covers (vented panel). z Screw a pair of rails to drive. z Slide in the drive install chassis. z Screw in two (2) 6#32 on th ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 9

    ZZ17-W2001-B 9 T o screw off four (4) screws in the front plate of chassis, the HDD cage could be removed from chassis, install HDD into cage. The cooling fan of HDD cage could be easy swap, release two thumb screws in the front of HDD cage, lift of f the fan holder , swap fan and assembly again into cage. How to use HDD brackets YY -W2 Server Chas ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 10

    ZZ17-W2001-B 10 3.6 Instructions for Switches and LED Indicators on front panel The switches and led indicato rs on front panel have the functions as following: POWER SW : Push Switch, The system power on/of f, connects t o M / B . Reset SW : Push switch, connect to M/B x POWR LED: The system power LED (green), connect to M/B. x POWER F AILUR ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 11

    ZZ17-W2001-B 11 Optional Intrusion Switch The chassis could be built with intrusion switch, assembly in left side of chassis, when side cover removed the system will alarm for intrusion, if connected. 3.7. Instructions for cooling fan assembly The chassis could be mounted optional two 60x60 cooling fans in rear mounted for strengthen the air flow b ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 12

    ZZ17-W2001-B 12 3.9 System Assembly When above steps are done, properly connect all accessories to the system. Then the user can start to install the O/S and required software to the system according to the instruction on the manual of Motherboard. 4. Intr oduction of IDE/SCSI/SA T A multi-bay backplane modules YY -W2 Server Chassis could be option ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 13

    ZZ17-W2001-B 13 5. How to change versatile as Rackmount Chassis (5U) 1. T o remove top cover and bottom cover of chassis. 2. Screw in rack bracket and handles T ype A+ SI-0357 x 1 T ype A+ SI-0237 x 2 ...

  • IBM 5U Rackmount Server Chassis YY-R5xx - page 14

    ZZ17-W2001-B 14 3. Slide into EIA cabinet ...

メーカー IBM カテゴリー Network Card

IBM 5U Rackmount Server Chassis YY-R5xxのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 5U Rackmount Server Chassis YY-R5xxの取扱説明書
- IBMの製品カード
- パンフレット
- またはIBM 5U Rackmount Server Chassis YY-R5xxの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、IBM 5U Rackmount Server Chassis YY-R5xxの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、IBM 5U Rackmount Server Chassis YY-R5xxの取り付け説明書、サービスマニュアル、簡易説明書、またはIBM 5U Rackmount Server Chassis YY-R5xxのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、IBM 5U Rackmount Server Chassis YY-R5xxの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

IBM 5U Rackmount Server Chassis YY-R5xxデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがIBM 5U Rackmount Server Chassis YY-R5xxを使用するのを助ける技術的文書のことです。説明書は通常、全てのIBM 5U Rackmount Server Chassis YY-R5xxユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

IBMの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. IBM 5U Rackmount Server Chassis YY-R5xxの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははIBM 5U Rackmount Server Chassis YY-R5xxの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。IBM 5U Rackmount Server Chassis YY-R5xxに関してこのドキュメントで見つけることができる全てのヒントの目次
3. IBM 5U Rackmount Server Chassis YY-R5xxデバイスの基本機能を使うにあたってのヒント。 IBM 5U Rackmount Server Chassis YY-R5xxのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。IBM 5U Rackmount Server Chassis YY-R5xxに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるIBM 5U Rackmount Server Chassis YY-R5xxのメーカー/サービスへの連絡先に関する情報。

IBM 5U Rackmount Server Chassis YY-R5xxについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもIBM 5U Rackmount Server Chassis YY-R5xxの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがIBM 5U Rackmount Server Chassis YY-R5xxで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)