Dometic 620515の取扱説明書

16ページ 0.36 mb
ダウンロード

ページに移動 of 16

Summary
  • Dometic 620515 - page 1

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 1 Important: These Instructions must stay with unit. Owner read carefully. REVISION: Form No. 3309083.016 2/05 (Replaces 3309083.008) (French 3309084.014) ©2005 Dometic Corporation LaGrange, IN 46761 USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 4651 ...

  • Dometic 620515 - page 2

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 2 SAFETY INSTRUCTIONS This manual has safety information and instruc- tions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for ...

  • Dometic 620515 - page 3

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 3 620515.331 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3.5 KW/5.0 KW 620515.336 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3.5 KW/5.0 KW 620525.331 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3 ...

  • Dometic 620515 - page 4

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 4 A . Precautions Improper installation may damage equipment, could endanger life, cause serious injury and/ or property damage. 1. Read Installation and Operating Instructions care- fully before attempting to start your air conditioner installation. 2. Dometic Corporation will n ...

  • Dometic 620515 - page 5

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 5 It is the responsibility of the installer of this air conditioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect. W a- ter standing around the air conditioner may leak into the interior causing damage to the pr ...

  • Dometic 620515 - page 6

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 6 It is the responsibility of the installer to insure the ductwork will not collapse or bend during and after the installation. Dometic Corporation will not be liable for roof structural or ceiling damage due to improperly insulated, sealed or collapsed ductwork. CAUTION Return A ...

  • Dometic 620515 - page 7

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 7 These items must be determined in conjunction with the Air Distribution System and Sizing and Design Require- ments listed in the chart on page 6. Terminate the start of the duct at the back edge of the 14-1/4" x 14-1/4" (±1/ 8"). See FIG. 7, 7A, and 7B. Importa ...

  • Dometic 620515 - page 8

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 8 D. Wiring Requirements 1. 120 VAC Supply Line Route a copper 12 AWG, with ground, 120 VAC supply line from the time delay fuse or circuit breaker box to the roof opening. a. This supply line must be located in the front portion of the 14-1/4" x 14-1/4" (±1/8") o ...

  • Dometic 620515 - page 9

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 9 Important: RJ-11-6C4P connectors must be installed as shown in FIG. 8A, 8B & 8C. 3. Comfort Control Center TM Installation a. Carefully remove the base plate from the Com- fort Control Center TM . This may be accom- plished by inserting a small screwdriver under the tab on ...

  • Dometic 620515 - page 10

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 10 CAUTION If bolts are left loose there may not be ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to specifications listed in this manual. e. Install the Romex connector in the junction box. f . Hold the cei ...

  • Dometic 620515 - page 11

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 11 Improper installation and sealing of divider plate will cause the compressor to quick cycle on the cold control. This may result in fuse or circuit breaker opening and/or lack of cool- ing. CAUTION c . Place divider plate up to bottom of air condi- tioner base pan firmly . The ...

  • Dometic 620515 - page 12

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 12 e. Use Aluminum foil tape (not supplied) to seal the ends of the foam divider to the sides of the opening. Make sure the area behind the flange on the ceiling template is sealed. See FIG . 22. 2. Center Discharge Duct Application Installation Note: If using non-center duct ins ...

  • Dometic 620515 - page 13

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 13 If bolts are left loose there may not be ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to specifications listed in this manual. CAUTION Improper installation and sealing of foam di- vider will cause the c ...

  • Dometic 620515 - page 14

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 14  Installing unit with 3308120 Genesis Air Filtra- tion System Return Air Kit. For 3105007 or 3105935 Return Air Kit, see page 14. 1. Install the slider in the return air cover and raise it to the ceiling template. Route the filter indicator wires from the return air cover t ...

  • Dometic 620515 - page 15

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 15 J . System Configuration, Reset & Check Out Now that the system is installed, it is necessary to check all operations and then configure the electronics. Refer to the Operating manual for a description of the air conditioner operation. 1. Electronic Control Kit Configurati ...

  • Dometic 620515 - page 16

    620515, 620525, 620526, 630515 & 630516 Installation Instructions 16 REAR REMOTE SENSOR (Required with Second Air Conditioner) REAR REMOTE SENSOR (Required with Second Air Conditioner) 14-1/4" x 14-1/4" (±1/8”) OPENING 14-1/4" x 14-1/4" (±1/8”) OPENING 14-1/4" x 14-1/4" (±1/8”) OPENING 14-1/4" x 14-1/ ...

メーカー Dometic カテゴリー Heat Pump

Dometic 620515のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 620515の取扱説明書
- Dometicの製品カード
- パンフレット
- またはDometic 620515の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Dometic 620515の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Dometic 620515の取り付け説明書、サービスマニュアル、簡易説明書、またはDometic 620515のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Dometic 620515の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Dometic 620515デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDometic 620515を使用するのを助ける技術的文書のことです。説明書は通常、全てのDometic 620515ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Dometicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Dometic 620515の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDometic 620515の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Dometic 620515に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Dometic 620515デバイスの基本機能を使うにあたってのヒント。 Dometic 620515のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Dometic 620515に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDometic 620515のメーカー/サービスへの連絡先に関する情報。

Dometic 620515についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDometic 620515の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDometic 620515で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)