    TECHNICAL M ANUAL FOR 2U GENESYS TM 5 kW Programmable DC Powe r Supplies Document: 83 - 515 - 00 0 Rev B TDK - L ambda A mericas Inc. 405 Essex R oad, Neptune, NJ 07753 Tel: (732) 922 - 9300 Fax: (732) 922 - 9334 Web: www . US.TDK - Lambda.com/HP ...

  • TDK 5KW - page 2

    ...

  • TDK 5KW - page 3

    ...

  • TDK 5KW - page 4

    GENESYS ™ Manual Supplement FOR UNITS EQUIPPED WITH “IEMD” OPTION, ALSO REFER TO MANUAL 83 - 030 - 200 IEMD. FOR UNITS EQUIPPED WITH “LAN” OPTION, REFER TO MANU AL 83 - 034 - 100. ...

  • TDK 5KW - page 5

    TA BLE OF CONTENTS W ARRANTY……………………………………………………………………………………………. Pg. 1 SAFETY INSTRUCT IONS…………………………………………………………………………….. Pg. 2 GERMAN SAFETY INST RUCTIONS………………………………………………………… ...

  • TDK 5KW - page 6

    TA BLE OF CONTENTS 3.8.8 Address se t ting……………….…………………………………………………………….. Pg. 18 3.8.9 Baud rate se t ting……………………………………………………………………………. Pg. 18 3.9 CONNECTING THE LOAD………………………………………………………… ...

  • TDK 5KW - page 7

    TA BLE OF CONTENTS 5.15.1 Basic parallel operati on…………………………………………………………………….. Pg. 42 5.15.2 Advanced paralle l operation……………………………………………………………….. Pg. 42 5.16 DAISY - CHAIN SHUT - OFF CONNECT ION……………………………………………? ...

  • TDK 5KW - page 8

    TA BLE OF CONTENTS 7.10.6 Status Control Co m mands………………………………………………………………... Pg. 63 7.11 STATUS, ERROR AND SRQ REGIST ERS…………………………………………………… Pg. 63 7.11.1 General Description………………………………………………………………………. Pg ...

  • TDK 5KW - page 9

    83 - 000 - 016 Rev. F WARRANT Y This TDK - Lambda Americas Inc. product is warranted aga inst defec ts in materials and workm anship for a period of five years fr om date of shipment. During t he warranty period, TDK - Lam bda Americas Inc. will, at it’s optio n, either rep air or replace products which prove to be defective. LIMITATION OF WARRAN ...

  • TDK 5KW - page 10

    83 - 515 - 000 Rev. B 2 SA FETY INSTRUCTIONS CA UTION The following safety precautions must be observed during all phase s of operation, servi ce and r e pair of this equipment. Failure to comply wi th the safety p recautions or warnings in this do cument violates safety st andards of design, manuf acture and intended u se of t his equipment and ma ...

  • TDK 5KW - page 11

    83 - 515 - 000 Rev. B 3 SA FETY INSTRUCTIONS ENVIRONM ENTA L CONDITIONS The Genesys TM power supply series safety approval applies to the f ollowing operating cond i tions: *Indoor use *Ambient temperature: 0°C to 50°C *Max imum relative humidi ty: 90% (no condensation) *Altitude: up to 3000m *Pollution degree 2 Do not use this product in environ ...

  • TDK 5KW - page 12

    83 - 515 - 000 Rev. B 4 SICHERHEITS - INSTA LLATIONS A NWEISUNGEN Vorsicht Vor Anschluss an das Netz ist die Aufstellanleitung wie nachstehend beschrie ben zu beachten. Die nachstehen den Sicherheitsanw eisug en mussen während al ler Phasen des B etriebes, des S ervices und der Reparatur dieser Ausrustung beachtet werden. Alle notwend igen Bedingu ...

  • TDK 5KW - page 13

    83 - 515 - 000 Rev. B 5 A nderungen and Bauteileersatz Ersatzteilaustausch – und Anderungen durfen nur von autorisiertem TDK - Lambda Americas Inc. SERVICE - PERSONEN du rchgef uhrt werden. Fur Reparaturen oder Anderungen ist das Gerat zur TDK - Lambda Americas Inc. Service - Niederlas sung zu retournieren. SICHERHE ITS - HINWEISE Umw eltbedingun ...

  • TDK 5KW - page 14

    83 - 5 15 - 0 00 Rev. B 6 CHA PTER 1 GENERA L INFORMA TION 1.1 USER MA NUAL CONTENT This User’s Manua l contains the o perating instruct ions, installation instructions and specifications of the Genesys TM 50 00W power supply se ries. The instructions ref er to the standard power supplies, including the built - in RS232/RS4 85 serial communicatio ...

  • TDK 5KW - page 15

    83 - 5 15 - 0 00 Rev. B 7  Cooling fan speed control for low noise and extende d fan lif e.  Zero stacking - no ventilatio n holes at the top and bottom surf ace of t he power suppl y.  Optional GPIB interface (SCPI compatible).  Optional Isolated Analog programming/ monitoring (0 - 5V or 0 - 10V, user selectable and 4 - 20mA). 1.2.4 Mu ...

  • TDK 5KW - page 16

    83 - 5 15 - 0 00 Rev. B 8 1.2.9 Cooling and mechanical construction The Genesys TM series is cooled by internal f ans. At the installation, care must be tak en to allow free ai r flow into the powe r supply vi a the front panel and out of the power supply via the rear panel. The Gen e sys TM power suppl ies have a compact and li ghtweight packag e, ...

  • TDK 5KW - page 17

    83 - 5 15 - 0 00 Rev. B 9 CHA PTER 2 SPECIFICA TIONS ...

  • TDK 5KW - page 18

    83 - 5 15 - 0 00 Rev. B 10 ...

  • TDK 5KW - page 19

    83 - 5 15 - 0 00 Rev. B 11 NOTES: *1: Minimum v oltage is guarantee d to maximum 0.2% of t he rated output voltage. *2: Mini mum cu r rent is guaranteed to maximum 0.4% of the rated output cur rent. *3: For cases w here conf ormance to v arious safety standards (UL, IEC etc.) is required, to be d e scribed as 190 - 240Vac ( 50/60Hz) for 3 - Phase 2 ...

  • TDK 5KW - page 20

    83 - 5 15 - 0 00 Rev. B 12 2.13 GENESYS TM 50 00W POW ER SUPPLIES OUTLINE DRA W INGS ...

  • TDK 5KW - page 21

    83 - 5 15 - 0 00 Rev. B 13 NOTE Gene sys TM power supplies generate magnetic fields, which might affect the operation of other instruments. If y our equipment is su s ceptible to magnetic f ields, do not position it adj a cent to the power supply . WA RNING To avoid electric shock hazard, do not insert co n d uctive parts through the front panel sl ...

  • TDK 5KW - page 22

    83 - 5 15 - 0 00 Rev. B 14 CA UTION Ensure that the screws used to attach the slides to the unit do not penetrate m ore than 6mm into the sides of t he unit. 3.4 RA CK MOUNTING The Genesys TM power suppl y series is designed to fit in a standard 19” equipment rack . 3.4.1 To install the Pow er Supply in a rack: 1. U se the front panel rack - moun ...

  • TDK 5KW - page 23

    83 - 5 15 - 0 00 Rev. B 15 WA RNING The AC input cord is not provided w ith t he power suppl y 3.7 AC INPUT POWER CONNECTION The power supply shall be connected to the AC source via protectiv e device (circuit br eaker, f uses, etc.) rated 30A max.. The power supply ON/OFF switch is not the main disconnect device and d oes not completely disco n- n ...

  • TDK 5KW - page 24

    83 - 5 15 - 0 00 Rev. B 16 2. Unscrew the base of t he strain relief f rom the helix - shaped body. Insert the base through the outside opening in the AC i n put cover and screw the lo cknut securely (11 - 14 Lb - inch.) (1.3 - 1.6Nm) in to the base, fr om the i n side. 3. Slide the heli x - shaped body on to the AC cable. Insert the str ipped w ir ...

  • TDK 5KW - page 25

    83 - 5 15 - 0 00 Rev. B 17 1 Remote (+ ) se nse 2 Local (+) se nse 3 Not con nect ed 4 Local (-) s ense 5 Remote (- ) sen se 3.8 TURN - ON CHECKOUT PROCEDURE 3.8.1 General The following procedure ensures that the power supp ly is operationa l and may be used as a basi c incoming inspection check. Refer to Fig . 4 - 1 and fig. 4 - 2 for t he locatio ...

  • TDK 5KW - page 26

    83 - 5 15 - 0 00 Rev. B 18 3. Momentarily press the OVP/UVL button so that the CURRENT display shows “OUP”. The VOLTAGE display will show the last se t ting of the OVP level. 4. Rotate the VOLT encoder CCW to adjust the OVP sett ing to 50 % of t he unit voltage rating. 5. W ait a f ew seconds until the VOLT display returns to show the Output Vo ...

  • TDK 5KW - page 27

    83 - 5 15 - 0 00 Rev. B 19 3.9 CONNECTING THE LOA D 3.9.1 Load Wiring Th e following considerations shoul d be made to select wiring for connecting the load to the power su p ply:  Current carrying capacity of the wire (refer t o Section 3.9.2)  Insulation rating of t he wire shoul d be at least equivalent to the maximum output volta ge of th ...

  • TDK 5KW - page 28

    83 - 5 15 - 0 00 Rev. B 20 CA UTION W hen local sensing, a short f rom +LS or +S to - V or - S or - LS, wil l cause damage to the power supply . Reversing the sense wires might cause damage to the power supply in local and remote sensing. (Do not connect - S to +V or +S t o - V). Max imum length in meters to limit voltage drop to 1V or less Cross s ...

  • TDK 5KW - page 29

    83 - 5 15 - 0 00 Rev. B 21 3.9.6 Making the load connections 8V to 100V Models Ref er to Fig. 3 - 6 for connection of the load wires to the pow er supply bus - bars and to Fig.3 - 7 for mounting the bus - bars shield to the chassis. WA RNING Hazard ous voltages may ex ist at the outputs and the load conne c- tions when usi ng a power supply with a ...

  • TDK 5KW - page 30

    83 - 5 15 - 0 00 Rev. B 22 WA RNING Hazardous v oltages exist at the outputs and the load connections. To protect personnel against accidental contact with haz ar dous vol tages, ensure that the load and its connections hav e no accessible liv e part s. Ensure that the load wiring insul ation rating is greater than or equal to the maximum output vo ...

  • TDK 5KW - page 31

    83 - 5 15 - 0 00 Rev. B 23 1. W ires: AW G 18 to AW G 10. 2. Tightening torq ue: 4.4 - 5.3 Lb - inch. (0.5 - 0.6Nm). Follow the instructions below for connection of the load wires to the pow er supply: 1. Strip approx. 10mm at the end of each of the wi res. 2. Loosen the connector terminal screws. 3. Insert the str ipped w ires into the terminal an ...

  • TDK 5KW - page 32

    83 - 5 15 - 0 00 Rev. B 24 3.9.7 Connecting single loads, local sensing (default). Fig.3 - 11 shows recommended load and sensing connections f or a single load. The local sense lines shown are default connections at th e rear panel J2 sense connector. Local sensing is suitable for a p- plications w here load regulation is less crit i cal. 3.9.8 Con ...

  • TDK 5KW - page 33

    83 - 5 15 - 0 00 Rev. B 25 - - R e m . s e n s e Lo cal s en se Lo cal s e ns e Rem. s ense + + Lo ad line s, twis te d pair , sh orte st l eng th p os sible . +V -V Lo ad# 1 + Lo ad# 3 + Lo ad# 2 + Powe r Sup ply Fig.3 -13: Mul tiple l oa ds c onnec tion, ra di al d istribution , l ocal se nse 3.9.10 Multiple load connection w it h distribution te ...

  • TDK 5KW - page 34

    83 - 5 15 - 0 00 Rev. B 26 WA RNING OUTPUT T ERMINAL GROUNDING There is a potential shock hazard at t he RS232/RS485 a nd the IEEE ports when using power supplies with rated or combined voltage greater t han 400V w ith the Positive Output of the power supplie s grounded. Do not connect the Positive ou t- put to ground when using the RS232/RS485 or ...

  • TDK 5KW - page 35

    83 - 5 15 - 0 00 Rev. B 27 3.10.3 Remote sensing Use remote sense where the load regulation at the load end i s critical. In remote sense, the power supply w ill compensate f or voltage drop on the load wi res. Refer to the powe r supply specific a tions for the maximum voltage drop on load w ires. The voltage drop is subtracted fr om the total vol ...

  • TDK 5KW - page 36

    83 - 5 15 - 0 00 Rev. B 28 CHA PTER 4 FRONT A ND REA R PA NEL CONT ROLS A ND CONNECTOR S 4.1 INTRODUCTION The Genesys TM Power Su pply series ha s a full set of cont rols, indicators and connectors that allow the user to easily setup and operate the unit. Before start ing to operate the unit, please read the f o l- lowi ng Sections for explanation ...

  • TDK 5KW - page 37

    83 - 5 15 - 0 00 Rev. B 29 Table 4 - 1: Front Panel C ontrols and Indicators Nu m ber Control/Indicator Description Se c tion 4 CURREN T display 4 digit, 7 segment LED display . Normally displ ays the ou t put Current. W hen the PREV button is pressed, the display i n- dicates the programmed sett ing of Output Cu r rent. 5 CURREN T indic a tor Gree ...

  • TDK 5KW - page 38

    83 - 5 15 - 0 00 Rev. B 30 Table 4 - 1: Front Panel Controls and Indicators (con tinued) Nu m ber Control/Indicator Description Se c tion 15 PREV indi cator Green LED, lights when PRE V button is pressed 16 FINE button Voltage and Current Fine/Coarse adjustment control. Operates as a toggle sw itch. In Fin e mode, the VOLTAGE and CURRENT encoders o ...

  • TDK 5KW - page 39

    83 - 5 15 - 0 00 Rev. B 31 Table 4 - 2: Rear panel Connecti ons and Controls (continued) Nu m ber Item Description Se c tion 4 Remote Out connector RJ - 45 type connector, used for daisy - chaining pow er supplies to form a serial communication bus. 7.3 7.4 5 J1 Analog pr o- gra m ming and monitoring co n- ne c tor Connector for r emote analog inte ...

  • TDK 5KW - page 40

    83 - 5 15 - 0 00 Rev. B 32 4.4.1 SW1 position function Refer to T able 4 - 3 for description of SW 1 position functions. The f actory default setting is Dow n for all positions. Table 4 - 3: SW 1 Positions Functions Position Func tion DOW N (Factory default) UP SW 1 - 1 Output Voltage Remote Analog Program ming Output Voltage Programm ed by Front P ...

  • TDK 5KW - page 41

    83 - 5 15 - 0 00 Rev. B 33 4.5 REAR PA NEL J1 PROGRAMM ING A ND MONITORING CONNECTOR The J1 Programm ing and Moni toring connector is a DB25 subminiature connector l ocated on the power sup ply rear pan el. Refer to Table 4 - 4 f or description of the connect or functions. T he power supply default conf iguration is Local operation, whi ch does not ...

  • TDK 5KW - page 42

    83 - 5 15 - 0 00 Rev. B 34 J1 co n tact Signal name Function Reference J1 - 1 ENA_IN Enable/Disabl e the power supply output by dry - contact (short/open) with ENA_OUT. Sec. 5.8 J1 - 2 J1 - 3 IF_COM Isolated Interf ace Common. Return for the SO control, PS_OK signal and for t he optional IEEE interface. Sec.5.7, 5.10 J1 - 4  7 N/C No Connection ...

  • TDK 5KW - page 43

    83 - 5 15 - 0 00 Rev. B 35 CHA PTER 5 LOCA L OPERA TION 5.1 INTRODUC TION This Chapter describes the operating modes that are not involv ed in programming and monitoring t he power supply v ia its serial communication port (RS232/RS485) or by remote analog signals. E n sure that the REM/LOC LED on the front panel is Of f, indicating Local mode. If ...

  • TDK 5KW - page 44

    83 - 5 15 - 0 00 Rev. B 36 - Enabled output, pow er supply in Co nstant Voltage mode: Press the PREV button and then r o- tate the CURRENT encoder knob. The C URRENT meter wil l show the programmed Output Current for 5 seconds after t he adjustment has been completed, and then will return to show the a c tual load current. - Enabled output, pow er ...

  • TDK 5KW - page 45

    83 - 5 15 - 0 00 Rev. B 37 5.4 A UNDER VOLTA GE LIMIT (UVL) The UVL prevents adjustment of t he Output Vol t age below a certain li mit. The combination of UVL and OVP functions, allow the user to create a protec tion win dow for sensitive load ci rcuitry. 5.4.1 Setting the UVL level Setting the UVL can be made when the pow er supply output is Enab ...

  • TDK 5KW - page 46

    83 - 5 15 - 0 00 Rev. B 38 useful f or connec ting power supplies i n a “Daisy - chain” (refer t o Section 5.16). The SO control can also be used to reset the OVP and Fold Protection (refer to Section 5.3 and 5.5 f or details). W hen the unit is shut - off by a J1 signal, the VOLTAGE display w ill show “SO” to indicate the unit state. J1 co ...

  • TDK 5KW - page 47

    83 - 5 15 - 0 00 Rev. B 39 *OTP *Enable/Di sable open (Power supply i s disabled) *OVP *SO (Rear panel Shut - Off , Power Suppl y is shut off) *Foldback *IEEE failure (W ith optional IEEE interface) *AC fail *Output Off 5.11 SAFE - STA RT AND A UTO - RESTA RT MODES W hen turning On the p ower supply AC On/Off, it can start to its last setting of Ou ...

  • TDK 5KW - page 48

    83 - 5 15 - 0 00 Rev. B 40 +S + - -S -LS +LS PO WER SU PPL Y +S + + - - -S -L S +LS PO WER SU PPL Y LO AD +S + - -S -LS +L S PO WER SU PPL Y +S + + - - -S -L S +LS PO WER SU PPL Y LO AD Fig.5-1 : Ser ies con nection , l ocal se nsin g Fig.5-2 : Ser ies con nection , r emote s ensing (*) (*) (*) (*) (*) D io d es a re us er su ppl ied . 5.14.1 Serie ...

  • TDK 5KW - page 49

    83 - 5 15 - 0 00 Rev. B 41 Fig.5 -3: S eries connec tion f or po sit ive/nega tive outpu t vo ltages +S + - -S -L S +LS PO WER SU PPL Y +S + + - - -S -L S +LS PO WER SU PPL Y (*) (*) (* ) D io de s are u se r supp lied . 3. Programming by external resistor: Programming by external resistor is possible. Refer t o Se c tion 6 - 5 for details. 4. Prog ...

  • TDK 5KW - page 50

    83 - 5 15 - 0 00 Rev. B 42 5.15 PA RA LLEL OPE RA TION Up to four units of the sam e VOLTAGE and CURREN T rating can be connected in parallel to prov ide up to four t imes the Output Current capability. One of the units operates as a Master and the remai n- ing units are Slaves. The Slav e units are analog programmed by the Master unit. In remote d ...

  • TDK 5KW - page 51

    83 - 5 15 - 0 00 Rev. B 43 6. Connection to the load In parallel operation, power supplies can be connected in local or remote sensing. Refer to Fig . 5 - 4 and 5 - 5 for typical connections of parallel powe r supplies. The f igures show connection of two units, howev er the same connection method applies for up to 4 units. 5.15.2 A dvanced paralle ...

  • TDK 5KW - page 52

    83 - 5 15 - 0 00 Rev. B 44 CA UTION Make sure that the c onnection betwe en – V terminals is reliable to avoid disconnection during operation. Disconnection may cause dam age to the power supply . NOTE W ith local sensing it is important to minim ize the w ire length and resistance. Also the positiv e and negative w ire resistance should be close ...

  • TDK 5KW - page 53

    83 - 5 15 - 0 00 Rev. B 45 Fig .5-6 : Da isy-c hain co nnect ion POWER SUPPL Y # 1 J1-2,3 J1-16 J1-16 J1-16 J1-15 PS_OK POWER SUPPL Y # 2 J1-2,3 J1-15 PS_OK SO POWER SUPPL Y #3 J1-2,3 J1-15 PS_OK SO SO IF_COM IF_COM IF_COM Fig.5 -5: P arallel opera tion with Rem ote s ensin g MASTER POWER SUPPL Y SLA VE#1 POWER SUPPL Y J1 -25 J1 -10 P IPG M J1 -12 ...

  • TDK 5KW - page 54

    83 - 5 15 - 0 00 Rev. B 46 CA UTION COM (J1 - 12), VPGM_RTN (J1 - 22) ter minals are connected AND IPGM_RTN (J1 - 23) term inal of J1 is ref erenced internally to the - Vout potential ( - V). Do not connect these terminals to any pot ential other than - Vout ( - V), as it may da m age the po wer suppl y. CHA PTER 6 REMOTE A NA LOG PROGRA MM ING 6.1 ...

  • TDK 5KW - page 55

    83 - 5 15 - 0 00 Rev. B 47 CA UTION To maintain the power supply isolation and to preven t ground loops, use an isolated programming source when operating the power supply via remote an a log programm ing at the J1 connector. 6.4 REMOTE VOLT A GE PROGRAMMING OF OUTPUT VOLTA GE A ND CURRENT LIMIT Perform t he following procedure to set the power sup ...

  • TDK 5KW - page 56

    83 - 5 15 - 0 00 Rev. B 48 1 14 13 25 10 9 23 22 CURRENT LIMIT PROGRA MMING OUTPUT VOL T AGE PROGRA MMING J1 connector , rear panel view Fig.6 -2: Re mote r esistive p ro grammin g PROGRA MMING RESISTO R PROGRA MMING RESISTO R OPTIONAL SE TS LOWER LIMIT OPTIONAL SE TS LOWER LIMIT OPTIONAL SE TS UPPER LIMIT OPTIONA L SET S UPPER LIMIT 12 8 6.5 RESIS ...

  • TDK 5KW - page 57

    83 - 5 15 - 0 00 Rev. B 49 6.6 REMOTE MONITORING OF OUTPUT VOLTA GE A ND CURRENT The J1 connector , located on the rear panel provides anal og signals f or monitoring the Output Vol t- age and Output Current. Selection of the voltage range between 0 - 5V or 0 - 10V is made by setup switch SW 1 - 4. The monitoring sig nals represent 0 to 100% of t h ...

  • TDK 5KW - page 58

    83 - 5 15 - 0 00 Rev. B 50 CHA PTER 7 RS232 & RS485 R EMOTE CONTROL 7.1 INTRODUCTION This Chapter describes the operation of the Genesys TM 50 00W power suppl ies via the serial comm u- nication port. Details of the initial set - up, operation via RS232 or RS 485, the command set and t he communication protocol are described in this Chap ter. 7 ...

  • TDK 5KW - page 59

    83 - 5 15 - 0 00 Rev. B 51 NOTE Tx and Rx are used for RS232 communication. Txd +/ - and Rxd +/ - are used for RS485 communication. Refer to RS - 232 and RS - 485 cabling and connection d e tails. 2. There are two Remote modes: 1. Remote: In this mode, return t o local can be made by the fr ont panel REM / LOC or via s e rial port command RM T 0. S ...

  • TDK 5KW - page 60

    83 - 5 15 - 0 00 Rev. B 52 7.4 MD MODE OPTION (Factory Installed) 7 .4.1 M D Mode Description The GEN supply is capable of operating in a multi drop environment - more than 1 supply co n ducting serial communications on a single serial bu s. A maximum of 31 GEN suppli es can operate in this si n- gle bus. Upon power up the Gen wil l enter the point ...

  • TDK 5KW - page 61

    83 - 5 15 - 0 00 Rev. B 53 7. 5 CONNECTING POWER SUPPLI ES TO RS232 OR RS485 BUS 7. 5.1 Single pow er supply 1. Selec t the desired interface RS232 or RS485 using rear panel setup switch SW 1 - 6 (Section 4 - 4). - RS232: DOW N position - RS485: UP position 2. Connect r ear panel IN connector to the cont roller RS232 or RS485 port using a suitable ...

  • TDK 5KW - page 62

    83 - 5 15 - 0 00 Rev. B 54 NOTE The address (ADR n) command must retur n an “OK ” response b e fore any other commands are accepted. 7.5.2 Multi pow er supply co n nection to RS232 or RS485 bus Up to 31 units can be connected (daisy ch ained) to the RS232 or RS485 bus. The first unit connects to the co n troller via RS2 32 or RS485 and the othe ...

  • TDK 5KW - page 63

    83 - 5 15 - 0 00 Rev. B 55 7.6.7 Error message If an error is detected in command or query, the power supply w ill respond with an error message. Refer to Section 7.7 f or details. 7.6.8 Backspa ce The backspace character ( ASCII 8) clears the last character sent to t he powe r supply. 7. 7 ERROR MESSA GES The power supply will return error messag ...

  • TDK 5KW - page 64

    83 - 5 15 - 0 00 Rev. B 56 7.8.3 Initiali zation Control Commands # Command Description 1 ADR n ADR is follow ed by address, w hich can be 0 to 30 and i s used to access the power sup ply . 2 CLS Clear status. Sets FEVE and SEVE registers t o zero (refer to Section 7 - 11). 3 RST Reset command. Brings the power supply to a safe and known state: Out ...

  • TDK 5KW - page 65

    83 - 5 15 - 0 00 Rev. B 57 # Command Desc ription 7 DVC? Display Vol tage and Current data. Data will be returned as a string of ASCII characters. A comma will separate the different fields. The f ields, in order, are: Measured V oltage, Progr ammed Voltage, Measured Current, Programmed Cu r- rent, Over Voltage Set Point and Under Voltage Set Point ...

  • TDK 5KW - page 66

    83 - 5 15 - 0 00 Rev. B 58 26 MODE? Returns the power supply operation mode. W hen the power supply is On (OUT 1) it wi ll return “CV” or “CC”. W hen the pow er supply is OFF (OUT 0 or fault shutdown) it wi ll r e turn “OFF”. 27 MS? Returns the M aster/Slave setting. M aster: n= 1, 2, 3, or 4 Slave: n=0 NOTES: 1. In Advanced paralle l m ...

  • TDK 5KW - page 67

    83 - 5 15 - 0 00 Rev. B 59 7.10 SINGLE BYTE COMMA NDS 7.10.1 General Single byte commands are commands in w hich all the necessary d ata for the supply to act upon is contained in a single by te. Single byte commands wil l be executed immed i ately by the supply. If the command require s data to be sent to the HOST PC or IEEE Board (see se c tions ...

  • TDK 5KW - page 68

    83 - 5 15 - 0 00 Rev. B 60 addressed supply a nd all non - addressed supplies, w ill respond to this command; but only the cu r- rently a d dressed supply (if any) w ill respond w ith the ‘OK’. 7.10.4 A ddressed commands w ith response 7.10.4.1 Read registers Send (0x80 + Address) (1 b yte binary - send 2 times sequentially). The supply w ill r ...

  • TDK 5KW - page 69

    83 - 5 15 - 0 00 Rev. B 61 Table 7 - 4. SINGLE BYTE COMM ANDS Name Bit Positions Response Description Global Commands Disable M D M ode 1010 0000 None Set supplies out of MD M ode (d e fault) Enable MD M ode 1010 0001 None Set supplies into M D Mode Disable SR Q r e transmission 1010 0010 None Disable retransmission of SRQs by su p- plies (default) ...

  • TDK 5KW - page 70

    83 - 5 15 - 0 00 Rev. B 62 Table 7 - 5: Voltage program ming range NOTE: The power supply can ac cept values higher 5 % than the table val ues, however it i s not reco m- mended to program the power supply bey ond the rated values. Table 7 - 6: Current pr ogramming range Model Minimum (A) Max imum (A) GEN8 - 6 00 000.00 6 00 .00 GEN1 0 - 50 0 000.0 ...

  • TDK 5KW - page 71

    83 - 5 15 - 0 00 Rev. B 63 7.10.6 Status Contro l Commands Refer to Section 7 - 8 for def inition of the reg isters. # Command Description 1 STT? Reads the complete pow er supply status. Returns ASCII characters representing the f ollowin g data, separated by commas: MV<actual (measured) vol tage> PC<programmed (set) current> PV<prog ...

  • TDK 5KW - page 72

    83 - 5 15 - 0 00 Rev. B 64 SR Q Me ssage s Res po nse me ssage s Com mand E rror (”Cnn ”) Exe cu tion E rror (”En n”) Qu ery Res ponse (”messa ge”) Com mand Res ponse (”OK”) CV CC NFL T FL T AST FDE 0 LCL CV CC NFL T FL T 0 0 0 LCL 0 0 0 Status Regist ers Condition Enable Event Con stan t V olt age Con stan t Cu r rent No F ault Fau ...

  • TDK 5KW - page 73

    83 - 5 15 - 0 00 Rev. B 65 7.1 1.2 Conditional Registers (continued) Table 7 - 9: Fault Condi tion Register BIT Fault name Fault symbol Bit Set condi tion Bit Reset condi tion 0 (LSB) Spare bit SPARE Fixed to zero Fixed to zero 1 AC Fail AC AC fail has occur red. The AC input returns to nor mal. 2 Over temper a ture OTP OTP s hutdown has o c curred ...

  • TDK 5KW - page 74

    83 - 5 15 - 0 00 Rev. B 66 7.11.3 Service Requ est: Enable and Ev ent Registers The conditional Registers are continuously monitored. W hen a change is detected in a register bit which i s enabled, the powe r supply w ill generate an SRQ message. The SRQ messag e is: “Inn” t erminated by CR, where the nn is the p ower supply address. The SRQ wi ...

  • TDK 5KW - page 75

    83 - 5 15 - 0 00 Rev. B 67 3. Status Enable Register The Status Enable Register is set by the user to Enable SRQs for changes in power supply status. Table 7 - 13: Status Enable Register BIT Status name Status sy m bol Bit Set cond i tion Bit reset condition 0 (LSB) Constant Voltage CV 1 Constant Current CC 2 No Fault NFLT 3 Fault active FLT User c ...

  • TDK 5KW - page 76

    83 - 5 15 - 0 00 Rev. B 68 7.12 SERIA L CO MMUNICA TION TEST SE T - UP Use the followin g instructions as basic set - up to test the serial communication operation. 1.Equipment : PC w ith W indows Hy per T erminal, software installed, Genesy s TM Power suppl y, RS232 cabl e. 2. PC set - up : 2.1 Open Hyper Termina l……………………. New Con ...

  • TDK 5KW - page 77

    83 - 5 15 - 0 00 Rev. B 69 CHA PTER 8 ISOLA TED A NA LOG PROGRA M M ING OPTION 8.1 INTRODUCTION Isolated Analog Programming is an internal Option Card for analog progr amming of the Genesys TM power suppl y series. The option is factory installed and cannot be obtained w ith a G PIB (IEEE - 488) Interf ace. Out put Voltage and Output Current can be ...

  • TDK 5KW - page 78

    83 - 5 15 - 0 00 Rev. B 70 CA UTION W hen the I solated Analog Option is installed, do not appl y any si gnals to the non - isolated VPGM and IPGM ( J1 - 9 an d J1 - 10) pins. All other J1 features may be used normally. Refer to Section 4.5 for a description of J1 featur es. 8.3 ISOLA TED PROGRA MMING & MONITORING CONNECTOR Refer to T able 8 - ...

  • TDK 5KW - page 79

    83 - 5 15 - 0 00 Rev. B 71 CA UTION To prevent damage to the unit, do not pr ogram the output voltage and current to higher t han the power suppl y rating. NOTE J1 - 8 and J1 - 12 must be shorted toget her with a w ire jumper. NOTE J1 - 8 and J1 - 12 must be shorted toget her with a w ire jumper. NOTE SW 1 position 3 and 4 must be in the Up positio ...

  • TDK 5KW - page 80

    83 - 5 15 - 0 00 Rev. B 72 CHA PTER 9 MAINT ENA NCE 9.1 INTRODUCTION This Chapter pr ovides i nform ation about maintenance, calibration and troublesh ooting. 9.2 UNITS UNDER WARRA NTY Units requiring r epair during the warranty period shoul d be returned to a TDK - Lambda Americas Inc authorized serv ice facility. Refer to the addresses listing on ...

  • TDK 5KW - page 81

    83 - 5 15 - 0 00 Rev. B 73 SYM PTOM CHECK ACTION REF Output Voltage wil l not adjust. Front panel CC LED is On. Is the unit in constant current mode? Check Output Current setting and load current. 5.2.1 5.2.2 Output Voltage wil l not adjust Front panel CV Led is On. Check if output voltage is adjusted above OVP setting or below UVL setting . Set OV ...

メーカー TDK カテゴリー Power Supply

TDK 5KWのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 5KWの取扱説明書
- TDKの製品カード
- パンフレット
- またはTDK 5KWの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、TDK 5KWの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、TDK 5KWの取り付け説明書、サービスマニュアル、簡易説明書、またはTDK 5KWのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、TDK 5KWの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

TDK 5KWデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTDK 5KWを使用するのを助ける技術的文書のことです。説明書は通常、全てのTDK 5KWユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

TDKの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. TDK 5KWの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTDK 5KWの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。TDK 5KWに関してこのドキュメントで見つけることができる全てのヒントの目次
3. TDK 5KWデバイスの基本機能を使うにあたってのヒント。 TDK 5KWのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。TDK 5KWに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTDK 5KWのメーカー/サービスへの連絡先に関する情報。

TDK 5KWについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTDK 5KWの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTDK 5KWで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)