    MODEL 5100-02-IT IT Series COMBUSTIBLE GAS SENSOR MODULE Version 2.00a APPLICABILITY & EFFECTIVITY Effective for all Model 5100-02-IT Modules manufactured after February 15, 2008. Instruction Manual Part Number T12019 Rev. B1 ...

  • Univex 5100-02-IT - page 2

    Model 5100-02-IT Combustible Gas Sensor Module FM APPROVAL ONLY THE FOLLOWING ITEMS, FUNCTIONS AND OPTIONS ARE FM * APPROVED Model 5100-02-IT Combustible Gas Sensor Module Sensor Module Model 5100-02-IT Combustible Gas Sensor Module Model 5100-02-IT-SS Combustible Gas Sensor Module, 316SS Calibration Equipment Model 1200-26 Calibration Gas Delivery ...

  • Univex 5100-02-IT - page 3

    Model 5100-02-IT Combustible Gas Sensor Module Contents TABLE OF CONTENTS 1. PRODUCT DES CRIPTION ............................................................................................................ ................. 3 1.1 GENERAL ............................................................................................................... ...

  • Univex 5100-02-IT - page 4

    Model 5100-02-IT Combustible Gas Sensor Module Contents 6.2 ENCLOSURE REPLACEM ENT .................................................................................................................... 23 6.3 TRANSMITTER REPLACEM ENT ................................................................................................................. 24 6 ...

  • Univex 5100-02-IT - page 5

    Model 5100-02-IT Combustible Gas Sensor Module Page: 3 1. PRODUCT DESCRIPTION 1.1 GENERAL The Model 5100-02-IT Catalytic Bead Combustible Gas Sensor Module is a member of the Sentry Information Technology ”IT” family of gas sensor transmitter modules. IT modules offer a broad array of features including: • Integral Alphanumeric display • 18 ...

  • Univex 5100-02-IT - page 6

    Model 5100-02-IT Combustible Gas Sensor Module Page: 4 Figure 1-2 Model 5100-02-IT Combustible Gas Sens or Module Aluminum – Dimensions Figure 1-1 Model 5100-02-IT Combustible Gas Sensor Module Stainless Steel – Dimensions ...

  • Univex 5100-02-IT - page 7

    Model 5100-02-IT Combustible Gas Sensor Module Page: 5 1.4.2 MODBUS OPERA TION All IT gas sensor modules have a Modbus RTU RS-485 serial interface to allow direct connection to any standard PLC or DCS. The Module Address Switch (section 3.5) allows the user to select Modbus addresses 1 thru 15. Switch position “0” allows t he user to set addres ...

  • Univex 5100-02-IT - page 8

    Model 5100-02-IT Combustible Gas Sensor Module Page: 6 1.6 INTERCONNECT WIRING Not supplied with the sensor module, but necessary to the installation and operation is the multi conductor wiring which connects the module to its power source and controller. Before this wiring is installed it is important to read and understand the cont rol system ins ...

  • Univex 5100-02-IT - page 9

    Model 5100-02-IT Combustible Gas Sensor Module Page: 7 2. CAUTIONS & WARNINGS 2.1 INTRODUCTION Although IT Transmitter Modules are designed and construct ed for installation and operation in industrial applications including "hostile" environment s, caution should be taken to insure that the installation is made in compliance with thi ...

  • Univex 5100-02-IT - page 10

    Model 5100-02-IT Combustible Gas Sensor Module Page: 8 2.3.1 CA TALYTIC BEA D SENSOR MODULES Model 5100-02-IT Gas Sensor Modules are FM perfo rmance approved for detection of Combustible gas (methane and hydrogen). The sensor is cross sensitive to the combustible gases indicated in Table 2-1. Risk management planning should take into consideration ...

  • Univex 5100-02-IT - page 11

    Model 5100-02-IT Combustible Gas Sensor Module Page: 9 3. INSTALLATION NOTE All IT modules are factory pre-configured and calibrated. All modules are tagged to indicate the configuration including the sensor module number. Identify all components during unpacking and in stall using the factory configuration. 3.1 SENSOR MODULE LOCATIONS Select locat ...

  • Univex 5100-02-IT - page 12

    Model 5100-02-IT Combustible Gas Sensor Module Page: 10 3.3 ENCLOSURE INSTALLATION To protect the transmitter and sensor assembly they should be removed from the enclosure and preserved until final installation and wiring termination. Prior to installation and wiring. 1. Remove the transmitter from the module housing by: • Unscrew the two captive ...

  • Univex 5100-02-IT - page 13

    Model 5100-02-IT Combustible Gas Sensor Module Page: 11 6. Carefully return the transmitter to the enclosure installing it over the two standoffs. Tighten the retaining screws into the standoffs. P1 F UNCTION P2 F UNCTION 1 High Alarm Relay NC 1 Power 2 High Alarm Relay NO 2 Signal 3 High Alarm Relay COM 3 Ground 4 Low Alarm Relay NC 4 N/A 5 Low Al ...

  • Univex 5100-02-IT - page 14

    Model 5100-02-IT Combustible Gas Sensor Module Page: 12 Figure 3-2 Connector Locations 3.5 INSTALLATION CONFIGURATION Table 3-3 and Figures 3-1 through 3-4 provide location and installation details. N OTE For Sentry applications only sensor addresses 1-8 are allowed. If using Modbus output sensor addresses 1-15 are available. Position 0 allows the ...

  • Univex 5100-02-IT - page 15

    Model 5100-02-IT Combustible Gas Sensor Module Page: 13 Figure 3-3 4-20 mA Connection ...

  • Univex 5100-02-IT - page 16

    Model 5100-02-IT Combustible Gas Sensor Module Page: 14 Figure 3-5 Remote Alarm Reset Figure 3-4 Digital Interface Connections ...

  • Univex 5100-02-IT - page 17

    Model 5100-02-IT Combustible Gas Sensor Module Page: 15 Figure 4-6 HMI Sw itch Locations 4. INTRODUCTION – HUMAN-MACHINE INTERFACE SYSTEM The Combustible Gas Sensor utilizes a visual menu sy stem operated by means of a magnet. A magnet stick is supplied for this purpose. The menu system is used to configure alarm set-points, calibrate the sensor ...

  • Univex 5100-02-IT - page 18

    Model 5100-02-IT Combustible Gas Sensor Module Page: 16 4.2 MAIN MENU Table 4-1 describes the primary human-machine interface operation. Function D isplay Description Reference M E ST M E ST ME S T ME S T M E ST M E ST M E ST M E ST M E ST M E ST M E ST Key Mode Switch [M] Enter Switch [E] Up Switch [ ▲ ] Previous Menu Down Swit ch [ ▼ ] Next M ...

  • Univex 5100-02-IT - page 19

    Model 5100-02-IT Combustible Gas Sensor Module Page: 17 4.3 CONFIGURE SET-POINTS The sensor module set-points menu is used to initially set-up the alarm set points, relay actions, gas type and range, 4-20 mA action and RS-485/ Sentry address and baud rates (See Menu Key in Appendix J). • Alarm Set-points: Once the Set-up menu is selected, pre ss ...

  • Univex 5100-02-IT - page 20

    Model 5100-02-IT Combustible Gas Sensor Module Page: 18 Functio n Display Description Reference M E ST M E ST M E ST M E ST ME S T ME S T ME S T ME S T M E ST M E ST Use S or T keys to adjust to new set point ME S T M E ST M E ST ME S T M E ST ME S T ME S T Table 4-3A Set-Up Configura tion Down *Sentry High Alarm Relay set to Sentry Down Sentry NOT ...

  • Univex 5100-02-IT - page 21

    Model 5100-02-IT Combustible Gas Sensor Module Page: 19 M E ST M E ST M E ST M E ST M E ST M E ST M E ST M E ST ME S T M E ST M E ST M E ST M E ST M E ST M E ST M E ST M E ST M E ST M E ST M E ST M E ST ME S T M E ST Down Baud S.P. Function - RS-485 Baud Rate Adj ust Enter *Track * = Curr ent selection Table 4-3B Set-Up Configur ation Enter *38400 ...

  • Univex 5100-02-IT - page 22

    Model 5100-02-IT Combustible Gas Sensor Module Page: 20 4.4 MAINTENANCE FUNCTIONS The maintenance menu allows the operator to monitor ce rtain Sensor values, and select the required analog or digital communication interface. The maintenanc e menu operation is described in Table 4-4. Function Displa y Description Reference M E ST M E ST M E ST M E S ...

  • Univex 5100-02-IT - page 23

    Model 5100-02-IT Combustible Gas Sensor Module Page: 21 5. CALIBRATION 5.1 CA LIBRATION FREQUENCY The manufacturer specifies that sens or modules must be calibrated every 180 days. Periodic functional tests are advisable for critical applicat ions and hostile environments. The sensor module microprocessor software includes high le vel self checking ...

  • Univex 5100-02-IT - page 24

    Model 5100-02-IT Combustible Gas Sensor Module Page: 22 Functio n Display Description Reference M E ST M E ST M E ST M E ST M E ST M E ST M E ST ME S T ME S T M E ST ME S T M E ST Banner: Operate m ode Table 5- 1 Calibration Sub-Routine B - Select Spa n Sub-Routine C - Ca libration F a il 0%LEL Default Display Enter CAL-FAIL Operation: No c ali bra ...

  • Univex 5100-02-IT - page 25

    Model 5100-02-IT Combustible Gas Sensor Module Page: 23 6. SERVICE 6.1 SENSOR MODULE CONFIGURA TION The gas sensor module is comprised of the following sub-assemblies (Figure 6-1): 5100-02-IT Gas Sensor Module SPL21810 Alluminum Enclosure (SPL32178 316SS Enclosure) SPL21813 Transmitter Assembly 5200-02 Sensor Assembly There are no field serviceable ...

  • Univex 5100-02-IT - page 26

    Model 5100-02-IT Combustible Gas Sensor Module Page: 24 6.3 TRA NSMITTER REPLA CEMENT The transmitter assembly should be replaced when it is determined that it is unre liable, noisy or cannot be calibrated. This may occur due to age, corrosion or failed components. To replace the transmitter assembly: a. Remove the cover of the main enclosure b. Un ...

  • Univex 5100-02-IT - page 27

    Model 5100-02-IT Combustible Gas Sensor Module Page: 25 • Wiring terminations clean and correct. 6.5.4 MOISTURE TRA PS AND RA INSHIELDS • Conduit seals and drains installed to avoid moisture build up in electronics enclosure. Water accumulation in sensor module enclosures is a major cause of damage and system failures - take precautions to seal ...

  • Univex 5100-02-IT - page 28

    Model 5100-02-IT Combustible Gas Sensor Module Page: 26 7. APPENDICES 7.1 APPENDIX A: SPECIFICATIONS Specifications: Sensor: Type: Catalytic Bead Range: 0-100% LEL Combustible Repeatability: +/-1% LEL Response time: < 12 sec to 60% full scale Accuracy : +/- 1% for 0-50% LEL range +/- 2% for 51-100% LEL range Sensor Life: Typically >3 years Ou ...

  • Univex 5100-02-IT - page 29

    Model 5100-02-IT Combustible Gas Sensor Module Page: 27 7.2 APPENDIX B: MODEL NUMBERS & PARTS LIST Sensor Module 5100-02-IT-AL Sensor Module, Co mbustible, Aluminum housing 5100-02-IT-SS Sensor Module, Combustible, 316SS housing Options 5311-00 Rainshield 5394-51 Remote Sensor/Display Option 5394-61 Auxiliary Connection Assembly 5394-62 Auxilia ...

  • Univex 5100-02-IT - page 30

    Model 5100-02-IT Combustible Gas Sensor Module Page: 28 7.3 APPENDIX C: LIMITED WARRANTY SIERRA MONITOR CORPORATION warrant s its products to be free from defec ts in workmanship or material under normal use and service for two years after date of sh ipment. SMC will repair or replace without charge any equipment found to be defective during the wa ...

  • Univex 5100-02-IT - page 31

    Model 5100-02-IT Combustible Gas Sensor Module Page: 29 7.4 APPENDIX D: REMOTE SENSOR DRAWING 5394-50 ...

  • Univex 5100-02-IT - page 32

    Model 5100-02-IT Combustible Gas Sensor Module Page: 30 7.5 APPENDIX E: AUXILIARY RELAY ASSEMBLY 5394-62 ...

  • Univex 5100-02-IT - page 33

    Model 5100-02-IT Combustible Gas Sensor Module Page: 31 7.6 APPENDIX F: AUXILIARY CONNECTION ASSEMBLY 5394-61 ...

  • Univex 5100-02-IT - page 34

    Model 5100-02-IT Combustible Gas Sensor Module Page: 32 7.7 APPENDIX G: AUXILIARY RS-485 MULTIDROP ASSEMBLY 5394-64 ...

  • Univex 5100-02-IT - page 35

    Model 5100-02-IT Combustible Gas Sensor Module Page: 33 ...

  • Univex 5100-02-IT - page 36

    Model 5100-02-IT Combustible Gas Sensor Module Page: 34 7.8 APPENDIX H: MODBUS MEMORY MAP Read Register Table Register Description Comments 40001 Concentration Gas Concentration multiplied by 100 40002 Temperature Temperature in degrees Celsius scalled by a factor of 100 40003 High Alarm Relay Boolean indicating the High Alarm Status, 0 No Alarm, 1 ...

  • Univex 5100-02-IT - page 37

    Model 5100-02-IT Combustible Gas Sensor Module Page: 35 7.9 APPENDIX I: COMBUSTIBLE GAS SCALING FACTORS For combustible gas monitoring, a calibration standar d of Methane may be used in conjunction with scaling factors to cause Sentry concentration display and alar m function in %LEL scale of another gas as follows: GAS METHANE FACTOR Acetaldehyde ...

  • Univex 5100-02-IT - page 38

    Model 5100-02-IT Combustible Gas Sensor Module Page: 36 7.10 APPENDIX J: Menu Key for 5100-02-IT Gas Sensor Module • Key M : MODE • Key E : ENTER • Key ▲ UP (+) • Key ▼ DOWN (-) MAIN MENU Use the M key to access each of the 4 main sections of the menu. M M M M M | | | | | |- A LMRSET : |- CA LIB : |- SETUP : |- MA INT : |- EXIT? ALARM R ...

  • Univex 5100-02-IT - page 39

    Model 5100-02-IT Combustible Gas Sensor Module Page: 37 SETUP MENU Once in the SETUP menu u se the ▲ or ▼ keys to access each of the 5 ma in sections of the SETUP menu. ▼ ▼ ▼ ▼ ▼ | | | | | |- A larms : |- Relays : |- GasFactr : |- 4-20mA : | - RS-485 SETUP: | E – Alarms (Alarms Set-Point Adjustment) | | | E – H.Alarm (High Alarm S ...

  • Univex 5100-02-IT - page 40

    Model 5100-02-IT Combustible Gas Sensor Module Page: 38 | |---- ▼ 4-20mA (Verifies 4mA or 20mA output and se lects condition of output during calibration) | | | ▼ -------or--------------- E Calib | | | | | |- Out: 4mA | | | | | ▼ --or— E (To calibrate analog output 4mA, | ▲ or ▼ to adjust level, | | | then E t o accept) | | |- Out : 20 ...

  • Univex 5100-02-IT - page 41

    Model 5100-02-IT Combustible Gas Sensor Module Page: 39 THIS PAGE INTENTIONALLY LEFT BLANK ...

メーカー Univex カテゴリー Carbon Monoxide Alarm

Univex 5100-02-ITのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 5100-02-ITの取扱説明書
- Univexの製品カード
- パンフレット
- またはUnivex 5100-02-ITの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Univex 5100-02-ITの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Univex 5100-02-ITの取り付け説明書、サービスマニュアル、簡易説明書、またはUnivex 5100-02-ITのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Univex 5100-02-ITの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Univex 5100-02-ITデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUnivex 5100-02-ITを使用するのを助ける技術的文書のことです。説明書は通常、全てのUnivex 5100-02-ITユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Univexの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Univex 5100-02-ITの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUnivex 5100-02-ITの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Univex 5100-02-ITに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Univex 5100-02-ITデバイスの基本機能を使うにあたってのヒント。 Univex 5100-02-ITのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Univex 5100-02-ITに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUnivex 5100-02-ITのメーカー/サービスへの連絡先に関する情報。

Univex 5100-02-ITについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUnivex 5100-02-ITの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUnivex 5100-02-ITで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)