Honeywell AP-100-BTの取扱説明書

32ページ 1.1 mb
ダウンロード

ページに移動 of 32

Summary
  • Honeywell AP-100-BT - page 1

    AP-010-BT and AP-100-BT Access Point Device with Bluetooth ® Wireless Technology Installation Guide ...

  • Honeywell AP-100-BT - page 2

    Copyright © 2008 Metrologic Instruments Inc. All ri ghts reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except b y reviewer, who may quote brief passages in a review, or provided for in the Cop yright Act of 1976. Trademarks Metrologic is a registered trademark of ...

  • Honeywell AP-100-BT - page 3

    ii T ABLE OF C ONTENTS Introduction Product Over view ............................................................................................. 1 Base Kit Components and Optional Acce ssories ............................................. 1 Componen ts .............................................................................................. ...

  • Honeywell AP-100-BT - page 4

    iii T ABLE OF C ONTENTS Uploading and Do wnloading Settings Uploading Settings via MetroSet 2 .................................................................. 15 Downloading Settings via MetroSet 2 .............................................................. 16 Upgrading the Firmware ............................................................. ...

  • Honeywell AP-100-BT - page 5

    1 I NTRODUCTION Honeywell’s access point devi ces with Bluetooth ® wireless technology provide customers with a flexible and convenient sol ution for wireless communication in a variety of environments, including reta il, healthcare, and manufacturing. The access point device separ ates charging functions from communication functions, allowing t ...

  • Honeywell AP-100-BT - page 6

    www.metrologic.com 2 I NTRODUCTION O PTIONAL A CCESSORIES Part # Description 55-55500-3 RS232 Straight PowerLink Cable, Black 55-55502-N-3 Keyboard Wedge Straight Cable, Black 55-55512-3 RS485 S Applications,Strai ght PowerLink Cable 55-55535-N-3 USB Type A Straight Cable, Black 55-55567-3 AUX Cable, Black S Applicable for IBM ® host applications. ...

  • Honeywell AP-100-BT - page 7

    3 I NTRODUCTION Mounting Specifications 1. Drill two, 1.6 mm pilot holes in the mounting surface. T he pilot holes should be located on a common centerline and be spaced 68.80 mm (2.70") apart. 2. Secure the access point device to the mounting surface with the M2.5 x 1.1 - 10 mm, Phillips wood screws provided with the access point. Figure 2. M ...

  • Honeywell AP-100-BT - page 8

    www.metrologic.com 4 I NTRODUCTION Product Labels The serial number label l ocated on the bottom of the access point device provides important information includi ng the model numb er, date of manufacture, serial number, address bar code, safet y and regulatory information. An additional copy of the address bar code is location on the to p of the d ...

  • Honeywell AP-100-BT - page 9

    5 I NSTALLATION Cable to Access Point Connection 1. Align the tab on the modular connec tor with the pinhole on the access poi nt device (see figure belo w). 2. Insert the modular connector into the device’s socket. 3. Test the cable’s connection to ensure the connector lock ha s engaged. Important: If the cable is not fully la tched, the unit ...

  • Honeywell AP-100-BT - page 10

    www.metrologic.com 6 I NSTALLATION USB Host Connections 1. Turn off power to the host system. 2. Plug the USB connector into the to a dedicated USB serial port. 3. Turn on power to the host system. Keyboard Wedge Host Connections 1. Turn off power to the host system. 2. Disconnect the keyboard from the host system. 3. Connect the “Y” ends of th ...

  • Honeywell AP-100-BT - page 11

    7 E STABLISHING C OMMUNICATION Between the Scanner and the Access Point Device To establish communication bet ween the scanner and access point device: 1. Connect the access point device to the host system ( see pa ges 5 - 6 ). 2. Scan the address bar code on the access poi nt device to establish a communication connection between th e scanner and ...

  • Honeywell AP-100-BT - page 12

    www.metrologic.com 8 A CCESS P OINT D EVICE O PERATION Page/Disconnect Button The access point has a button located on the top of the device that can be used to either page the scanner or disconn ect the communication link bet ween the scanner and the access point. Figure 11. The page and dis connect button feature s are not supported in CodeXML pr ...

  • Honeywell AP-100-BT - page 13

    9 C ONFIGURATION P ROCEDURES The following information is for replaceme nt applications or situations requiring scanner reconfiguration. Some of the configuration proce dures require the user to scan the recall defaults bar code. If the recall def aults code is scanned, the scanner’s factory pre-configurations a nd custom configurations w ill be ...

  • Honeywell AP-100-BT - page 14

    www.metrologic.com 10 C ONFIGURATION P ROCEDURES CodeXML Protocol Compatibility The CodeXML protoco l does not support page/disconn ect button functions, or scanner firmware upgrades thr ough the access point device and Metros et 2 . When a scanner is using the Code XML protoc ol, confi guration data is stored in the scanner. The stored data is not ...

  • Honeywell AP-100-BT - page 15

    11 C ONFIGURATION P ROCEDURES Access Point Device Configuration in CodeXML Mode When a scanner is using the Code XML protocol all confi guration data is stored in the scanner. Since the data is not transmitted to the access point device, the following process is required to configure the device for cust om system formats or protocol requirements. T ...

  • Honeywell AP-100-BT - page 16

    www.metrologic.com 12 C ONFIGURATION P ROCEDURES Optional Configuration Bar Codes The following bar codes are for reference onl y. Suffix Characters Disable Carriage Return Suffix ³ 11 6603 Enable Carriage Return Suffix ³ 11 6613 The scanner transmits a carriage return after each bar code. Disable Line Feed Suffix ³ 11 6602 Enable Line Feed Suff ...

  • Honeywell AP-100-BT - page 17

    13 C ONFIGURATION P ROCEDURES The following bar codes require an estab lished communication link bet ween the access point device and a scanner usin g the Metro Protocol. Default settings are marked with an asterisk ( * ). Send Bluetooth ® Software Version ³ 99 8044 Send Address ³ 99 8045 Communications Load RS232 Defaults ³ 99 9992 Load Keyboa ...

  • Honeywell AP-100-BT - page 18

    www.metrologic.com 14 C ONFIGURATION P ROCEDURES Country/Scan Code Table S elects * Enable USA Keyboard ³ 41 6260 Enable Swiss Keyboard ³ 41 6280 Enable Spanish Keyboard ³ 41 6250 Enable Italian Keyboard ³ 41 6240 Enable German Keyboard ³ 41 6230 Enable French Keyboard ³ 41 6220 Enable UK Keyboard ³ 41 6210 Enable Belgium Keyboard ³ 41 6200 ...

  • Honeywell AP-100-BT - page 19

    15 U PLOADING AND D OWNLOADING S ETTINGS Uploading Settings via MetroSet 2 The upload † feature in MetroSet 2 allo ws the user to retr ieve the current software number and configuration settings of an acce ss point device connected to a personal computer. To upload settings via MetroSet 2 : 1. Verify the access point device is connected to the ho ...

  • Honeywell AP-100-BT - page 20

    www.metrologic.com 16 U PLOADING AND D OWNLOADING S ETTINGS Downloading Settings via MetroSet 2 The download † feature in MetroSet 2 allo ws the user to download custom configuration settings selected in MetroSet 2 to the access point an d the linked scanner ‡ . To download settings via MetroSet 2 : 1. Verify the access point device is connecte ...

  • Honeywell AP-100-BT - page 21

    17 U PGRADING THE F IRMW ARE Upgrading the Firmware in the Access Point Device The access point device is part of Metrologic's product series with flash upgradeable firm ware. The upgrade process requires, a ne w firmware file supplied to the customer by a customer service repres entative  and Metrologic's MetroSet 2 software  . ...

  • Honeywell AP-100-BT - page 22

    www.metrologic.com 18 U PGRADING THE F IRMW ARE Upgrading FocusBT Firmware via the Access Point Device With MetroSet 2 , scanner firmware upgrades can be accom plished through the communication link bet ween the access point device and scanner. This feature is not supported in scanners using the CodeXML prot ocol. The scanner must be in Metro proto ...

  • Honeywell AP-100-BT - page 23

    19 D ESIGN S PECIFICATIONS Access Point Device O PERATIONA L System Interfaces: RS232, Keyboard W edge, RS485 S , USB S Applicable for IB M ® Host applic ations. Indicator: Blue LED M ECHANICAL Length: 111 mm (4.4") Width: 77 mm (3.0") Height: 16 mm (0.6") Weight: 75 g ( 2.7 oz ) E LECTRICAL AP-010-BT AP-100- BT Input Voltage: 5.0VD ...

  • Honeywell AP-100-BT - page 24

    www.metrologic.com 20 D EVICE AND C ABLE T ERMINATIONS The access point device terminates to a singl e 10-Pin RJ45, Female Socket. The following charts provide the pinout inf ormation for each of the available interfaces. RS232 10-Pin, RJ45 Pin Function 1 Ground 2 CTS RS232 Input 3 Receive RS232 Input 4 Reserved 5 Reserved 6 RTS RS232 Output 7 Rese ...

  • Honeywell AP-100-BT - page 25

    21 D EVICE AND C ABLE T ERMINATIONS Cable Pinout Connections RS232 PowerLink Cable MLPN 55-55500 Pin Function 1 Shield Ground 2 CTS 3 RXD 4 Reserved 5 Reserved 6 RTS 7 Reserved 8 TXD 9 +5VDC 9-Pin D-Type Connector USB Communication Cable MLPN 55-55535 Pin Function 1 PC +5V/V_USB 2 D- 3 D+ 4 Ground Shield Shield Non-Locking, Type A RS485 S Cable MLP ...

  • Honeywell AP-100-BT - page 26

    www.metrologic.com 22 D EVICE AND C ABLE T ERMINATIONS Cable Pinout Connections Keyboard Wedge Cable MLPN 55-55502 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC 5-Pin DIN, Female Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect 6-Pin DIN, Male Metrologic will supply a ...

  • Honeywell AP-100-BT - page 27

    23 R EGULATORY C OM PLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022, EN300 328 V1.6.1, EN310 489-17 V 1.2.1 Immunity CISPR 24, EN 55024 Note: Immunity performance i s not guaranteed for scanner cables greater than 3 me ters in length when fully ex tended. Changes or modifications n ot expressly approved by the party responsible fo r ...

  • Honeywell AP-100-BT - page 28

    www.metrologic.com 24 R EGULATORY C OM PLIANCE Changes or modifications n ot expressly approv ed by t he party responsible fo r compliance could void the user’s authority to operate the equipme nt. Class B Devices The follo wing is applicable when the cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessou ...

  • Honeywell AP-100-BT - page 29

    25 L IMITED W ARRANTY The AP-010-BT and AP-100-BT a ccess point devices are manufactured by M etrologic at its Suzhou, China facility. The AP-010-BT and AP-100-BT access poi nt devices hav e a two (2) year limited w arranty from the date o f manufacture. Metrologic w arrants and represents tha t allAP-010-BT and AP-100-BT access point devices are f ...

  • Honeywell AP-100-BT - page 30

    www.metrologic.com 26 I NDEX A AC .................................. see pow er Accessori es .................................. 2 Address Ba r Code ........................ 2 B Blue ............................ see indicator Button ................................... 17, 18 C Cable AUX .......................................... 2 Keyboard Wedge ... ...

  • Honeywell AP-100-BT - page 31

    ...

  • Honeywell AP-100-BT - page 32

    70-79035A October 2008 Printed in China © 2008 Honeywell International Inc. ...

メーカー Honeywell カテゴリー Mobility Aid

Honeywell AP-100-BTのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AP-100-BTの取扱説明書
- Honeywellの製品カード
- パンフレット
- またはHoneywell AP-100-BTの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Honeywell AP-100-BTの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Honeywell AP-100-BTの取り付け説明書、サービスマニュアル、簡易説明書、またはHoneywell AP-100-BTのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Honeywell AP-100-BTの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Honeywell AP-100-BTデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHoneywell AP-100-BTを使用するのを助ける技術的文書のことです。説明書は通常、全てのHoneywell AP-100-BTユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Honeywellの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Honeywell AP-100-BTの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHoneywell AP-100-BTの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Honeywell AP-100-BTに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Honeywell AP-100-BTデバイスの基本機能を使うにあたってのヒント。 Honeywell AP-100-BTのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Honeywell AP-100-BTに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHoneywell AP-100-BTのメーカー/サービスへの連絡先に関する情報。

Honeywell AP-100-BTについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHoneywell AP-100-BTの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHoneywell AP-100-BTで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)