    SieMo S50037 Data Book PRELIMINARIL Y Page 1/30 Data Book Siemens Bluetooth™ Modul e SieMo-S50037 S50037-Q5- * Copyright  Siemens AG 2002 All Rights Reserved. ...

  • Siemens S50037 - page 2

    SieM o S50037 Data Book PRELIMINARILY File Name: SieMo_S5003 7 Data Book.do c Page 2/30 SieMo S50037 KEY Features  Blueto oth V1.1 prequa lifie d  Input sens itiv it y –85 dBm  Point-to-m ultipoin t functio nalit y  Firm ware belo w HCI em bedded, or stand alone op eration  Class 2 Bluetooth devic e, 2 d Bm  HCI optiona ll y via ...

  • Siemens S50037 - page 3

    SieM o S50037 Data Book PRELIMINARILY File Name: SieMo_S5003 7 Data Book.do c Page 3/30 A uthor Part of this Documen t Departmen t Canbolant D. Regulatory Stat ements, Bluetooth™ Trademark PSE PRO RCD 3 Jatschka T. Technical Clauses PSE PRO RCD 3 ...

  • Siemens S50037 - page 4

    SieM o S50037 Data Book PRELIMINARILY 4/30 General In fo rmat ion History Issue Date Reason for Changes 01 2002-02-12 Initial issue 02 2002-02-25 Redesign of document structure, inserting of the Clause Regulatory Statements 03 2002-03-13 Enhanced Details in Interface Description 04 2002-03-21 Manufacturing aspects added, minor corrections. 05 2002- ...

  • Siemens S50037 - page 5

    SieM o S50037 Data Book PRELIMINARILY 5/30 CONTENT General Infor mation .................................................................................................... 4 His tory................................................................................................................................ 4 Refe rences......................... ...

  • Siemens S50037 - page 6

    SieM o S50037 Data Book PRELIMINARILY 6/30 Manufacturing aspects, Handling .............................................................................. 25 Regulatory Statements ............................................................................................. 26 General .................................................................. ...

  • Siemens S50037 - page 7

    SieM o S50037 Data Book PRELIMINARILY 7/30 2.4 GHz Radio I/O RAM DSP µP SPI USB UART PCM PIO 2-6 Power Supply V CC V IO XTAL FLASH MODE Bal un LNA SWITCH ANT TX EN /RX EN V REG Reset BC01b figure 1 Block Diagram figure 2 Default HCI- FW Stack optional FW stac k for standal one operation ...

  • Siemens S50037 - page 8

    SieM o S50037 Data Book PRELIMINARILY 8/30 Electrica l Characteristics A bsolute Maximum Ratings Rating Min. Max. Storage Temperature -30°C +85°C Supply Voltage Vcc (no damage) -7V +7V Supply Voltage Vcc-IO 0V +3.6V 5V Tolerant Terminals -0. 4V +5.5V Other Terminals -0.4V +3. 55V Input Rf Power, in band 5dBm Recommended Operating Conditions Opera ...

  • Siemens S50037 - page 9

    SieM o S50037 Data Book PRELIMINARILY 9/30 V IL input logic level low V IH input log ic level high - 0.7 Vcc_IO - - 0.3 Vcc_IO - V V Input leakage current -1 - 1 µA C I Input Capacitance 2.5 - 10 pF Outpu t lev els (to correc tly te rmina ted USB) V OL output logic level low V OH output logic level high 0 2.8 - - 0.2 Vcc_IO V V PIO Port Outpu t vo ...

  • Siemens S50037 - page 10

    SieM o S50037 Data Book PRELIMINARILY 10/30 C/I Co-channel 6 -9- 1 1 d B Adjacent channel selectivity C/I 1MHz 3 -- 2- 0 d B 2 nd adjacent channel selectivity C/I 2MHz 3 - -34 - -30 dB 3 rd adjacent channel selectivity C/I >3MHz 3, 4 - -45 - -40 dB Im ag e rej e ctio n C /I 3, 5 -- 1 4- - 9 d B Maximum level of intermodulat ion interferers 3, 6 ...

  • Siemens S50037 - page 11

    SieM o S50037 Data Book PRELIMINARILY 11/30 Output spectr um in the w hole 2,4 GHz ISM ban d (Max H old) figure 4 Out put sp ectrum with Frequ enc y Hopping m easur ed with MAX HOLD cable loss ( approx. 3d B) not correc ted. Flatness o f output pow er Vs time figure 5 o utput po wer during a DH5 pack et, cable loss (appr ox. 3dB) not corr ected. Sp ...

  • Siemens S50037 - page 12

    SieM o S50037 Data Book PRELIMINARILY 12/30 VCO Settl ing S-Pa ramet er of th e An tenna port figure 7 VCO settling during FH operation in two different time-scales figure 8 S11 on the antenna port in transmit mode figure 9 S11 on the antenna port in receive mode ...

  • Siemens S50037 - page 13

    SieM o S50037 Data Book PRELIMINARILY 13/30 Pin Descripti on Pinout Diagram figure 10 SieMo Pinout, bottom view Pin description table Row X,D,E and F are by default not prov ided with soldering bumps Pin Name Type Pin Description RF ANT Rf in/out T2 Antenna output, 50 Ω ; unconditionally stable; DC path to GND TX-EN CMOS output, pulled down F5 7 ...

  • Siemens S50037 - page 14

    SieM o S50037 Data Book PRELIMINARILY 14/30 USB-Int erface D+ C MOS bi-direc tional B1 USB D+ D- CMOS bi-di rectional B2 USB D- USB_PULL_UP / PIO[ 2] CM OS bi-directional, pulled down D1 8 USB Pull-up, int ernally attached to D+ , only used with corresponding USB-s ettings. USB_W AKE_UP =USB _RESU ME / PIO[3] CM OS bi-directional, pulled down B4 O ...

  • Siemens S50037 - page 15

    SieM o S50037 Data Book PRELIMINARILY 15/30 figure 11 dimmensions ...

  • Siemens S50037 - page 16

    SieM o S50037 Data Book PRELIMINARILY 16/30 Interface Descript ion PCM Interfa ce Overv iew  PCM Pulse Code Modulation is a standard method used to di gitise human voice  Four-wire, f ull duplex serial interface used to transfer a single voice channel to an external audio codec  Maximum of one SCO connection is possible using the PCM inter ...

  • Siemens S50037 - page 17

    SieM o S50037 Data Book PRELIMINARILY 17/30 PCM Timi ng Symbol Parame ter Min Ty p Ma x Unit f CLK PCM clock frequency 256 kHz (1) Clock duty cy cle 50 % t sy :hd Hold time from CLK low to SYNC high 1.95 us t sy :su Se t-up ti me fo r SYNC high to CL K lo w 1.95 us t sdat:dt Delay time f rom CLK to valid MSB data 50 ns t dat:dt Del ay ti me fro m C ...

  • Siemens S50037 - page 18

    SieM o S50037 Data Book PRELIMINARILY 18/30 Timing graphs figure 15 PCM clock (upper) Vs PCM sync in 2 different time-scales figure 15 PCM OUT Vs PCM CLOCK in two different time-scales figure 15 PCM OUT Vs PCM SYNC in two different time-scales ...

  • Siemens S50037 - page 19

    SieM o S50037 Data Book PRELIMINARILY 19/30 UA RT Int erface Overv iew  Universal Asynchronous Receiver Transmitter  Standard 16550 compatible UART interface  Min 9600Baud, Max 1.5MBaud  UART_TX and UART_RX used to transmit data  UART_CTS and UART_RTS used to implement RS232 hardware flow control The UART (Universal Asynchronous Rece ...

  • Siemens S50037 - page 20

    SieM o S50037 Data Book PRELIMINARILY 20/30 Application: SieMo connected as DCE figure 17 Connecti on to PC via le vel c onvert er Timing graphs figure 18 UART T xD signal figure 19 data o utput stop ped b y handshak e in put, delay tim e 84us ...

  • Siemens S50037 - page 21

    SieM o S50037 Data Book PRELIMINARILY 21/30 USB Interface Overv iew  12M bits/s bi t rate  BC01 operates as a peripheral USB device  Two modes, bus pow ered and self powered  Careful product design is required for product to remain USB1.1 compliant  4 USB lines are required  Minimum voltag e on VCC_IO terminal is 3.0V for USB oper ...

  • Siemens S50037 - page 22

    SieM o S50037 Data Book PRELIMINARILY 22/30 figure 20 USB Po wer Modes- Applicati ons USB Timi ng figure 21 USB D isconnect and Resum e Si gnal T iming Serial Periphera l Interface Overv iew  Consistent with the Motorola SPI standard  SieMo always acts in slave mode  SPI_CLK is always generated by the host SieMo uses 16-bit addresses and 1 ...

  • Siemens S50037 - page 23

    SieM o S50037 Data Book PRELIMINARILY 23/30 Multi- Slave Operati on SieMo should not be connected in a multi-slave arr angement by simple parallel connection o f slave MISO lines. W hen SieMo is deselected (SPI_CSB = 1), the SPI_MISO line does not float. Instead, SieMo outputs 0 if the processor is running or 1 if it is stopped. W riting to SieMo T ...

  • Siemens S50037 - page 24

    SieM o S50037 Data Book PRELIMINARILY 24/30 Reading from SieMo Reading is similar to writing, in that an 8-bit read command (00000011) is sent first, followed by the address of the loca tion to be read. The SieM o then outputs the 16-bit contents of the location on MISO during bits D[15:0] and a check-word during T[ 15:0].The check-word is composed ...

  • Siemens S50037 - page 25

    SieM o S50037 Data Book PRELIMINARILY 25/30 Manufacturing aspects, Handli ng The SieMo device is moisture sensitive according to JEDEC / JST Level 4, e.g. should be stored within Dry Pack until used, and exposed to ambient air of max. 30°C / 60% rel. Humi dity fo r a ma ximu m of 72h . As the device is electrostatic sensitive, standard ESD precaut ...

  • Siemens S50037 - page 26

    SieM o S50037 Data Book PRELIMINARILY 26/30 Regulatory Statements General • Thi s Bluetooth radio module has to be ins talled and used in accordance w ith the technical description/inst allation instructions provided by the manu f acturer. • Thi s Bluetooth radio module is intended to be placed on the market in all States, where the Bluetooth T ...

  • Siemens S50037 - page 27

    SieM o S50037 Data Book PRELIMINARILY 27/30 Because this Bluetooth™ radio module is very small and intended to be integrated/installed in final products (OEM products/applications) it is not practicable to place the label including the CE conformity mark ing on it. Therefore the required labelling inf ormation is placed in this technical descript ...

  • Siemens S50037 - page 28

    SieM o S50037 Data Book PRELIMINARILY 28/30 Note that in case of using the p rovided auxiliary label, additionall y following statement has to be included in the users manual o f the final product (OEM product/application): This device complies with part 15 of the Federal Co mmunications Commission (FCC) Rules. Operation is subject to the following ...

  • Siemens S50037 - page 29

    SieM o S50037 Data Book PRELIMINARILY 29/30 Bluetooth-Trademark is a trademark owned by Bluetooth SIG, I nc., U.S.A, and licensed to Siemens AG. This product is a qualified Bluetooth TM product and compliant to the Bluetooth TM specifications version 1.1. ...

  • Siemens S50037 - page 30

    SieM o S50037 Data Book PRELIMINARILY 30/30 Appendix A List of figures figu re 1 B loc k Dia gram ......................................................................................................... .7 figure 3 Modulation spectrum on single channel with PRBS9 Payl oad, DH1 pack et cable loss (approx. 3dB ) not co rrected . .................... ...

メーカー Siemens カテゴリー Barcode Reader

Siemens S50037のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- S50037の取扱説明書
- Siemensの製品カード
- パンフレット
- またはSiemens S50037の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Siemens S50037の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Siemens S50037の取り付け説明書、サービスマニュアル、簡易説明書、またはSiemens S50037のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Siemens S50037の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Siemens S50037デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSiemens S50037を使用するのを助ける技術的文書のことです。説明書は通常、全てのSiemens S50037ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Siemensの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Siemens S50037の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSiemens S50037の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Siemens S50037に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Siemens S50037デバイスの基本機能を使うにあたってのヒント。 Siemens S50037のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Siemens S50037に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSiemens S50037のメーカー/サービスへの連絡先に関する情報。

Siemens S50037についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSiemens S50037の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSiemens S50037で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)