White Rodgers 50A55-843の取扱説明書

8ページ 0.06 mb
ダウンロード

ページに移動 of 8

Summary
  • White Rodgers 50A55-843 - page 1

    FIRE HAZARD • Do not exceed the specified voltage. • Protect the control from direct contact with water (dripping, spraying, rain, etc.). • If the control has been in direct contact with water, replace the control. • Label all wires before disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation. • ...

  • White Rodgers 50A55-843 - page 2

    2 SPECIFICA TIONS ELECTRICAL RATINGS [@ 77 ° F (25 ° C)]: Input Voltage: 25 VAC 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings: Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive) Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VAC Circulator Relay: 14.5 FLA–25.0 LRA @ 120 VAC Flame Curr ...

  • White Rodgers 50A55-843 - page 3

    3 INST ALLA TION MOUNTING AND WIRING All wiring should be installed according to local and national electrical codes and ordinances. The control must be secured to an area that will experience a minimum of vibration and remain below the maximum ambient temperature rating of 175 ° F. The control is approved for mini- mum ambient temperatures of -40 ...

  • White Rodgers 50A55-843 - page 4

    4 TH TR MV MV GND FP HLO HLI PS C R G W Y EAC N HUM N XFMR N LINE N CIR N IGN IND IGN N IND N HUM EAC XFMR LINE PARK PARK HEAT COOL IGNITOR Y W G R THERMOSTAT GAS VALVE HIGH LIMIT (N. C.) ROLLOUT (N. C.) AUX. HIGH LIMIT (N. C.) PRESSURE SWITCH (N. O.) FLAME SENSOR PROBE COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER HUMIDIFIER INDUCER CIRCULATOR BLOWE ...

  • White Rodgers 50A55-843 - page 5

    5 50A55 TERMINAL TERMINAL TYPE SYSTEM COMPONENT CONNECTION TYPICAL SYSTEM WIRING TABLE W G R Y C TWIN* MV (2 terminals) TR TH RO1 RO2 FP PS HLI HLO GND (unused terminal) IND IGN IND N IGN N COOL HEAT PARK (2 terminals) LINE XFMR EAC (optional) HUM (optional) CIR N LINE N XFMR N EAC N (optional) HUM N (optional) Terminal block with captive screws 12 ...

  • White Rodgers 50A55-843 - page 6

    6 OPERA TION OPTION SWITCHES The option switches on the 50A55-843 control are used to determine the length of the cool delay-to-fan-off, heat delay-to- fan-on and heat delay-to-fan-off periods. The following table shows the time periods that will result from the various switch positions. HEA T MODE In a typical system, a call for heat is initiated ...

  • White Rodgers 50A55-843 - page 7

    7 TWINNING INTERF A CE If the control has six screw terminals, one of which is designated TWIN , the control is equipped with a single wire twinning interface. If twinning is used, either control will process a call for heat, cool or fan as described above. However, after the heat-, cool-, or fan-on delay time expires, both units will energize the ...

  • White Rodgers 50A55-843 - page 8

    MOUNTING HOLE TEMPLA TE FOR MOUNTING HOLE LOCA TIONS 4.172 ± .007 (2 plcs.) 6.402 ± .010 (2 plcs.) Refer to page 3 of the installation instructions for proper installation. MOUNTING HOLE TEMPLA TE ...

メーカー White Rodgers カテゴリー Furnace

White Rodgers 50A55-843のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 50A55-843の取扱説明書
- White Rodgersの製品カード
- パンフレット
- またはWhite Rodgers 50A55-843の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、White Rodgers 50A55-843の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、White Rodgers 50A55-843の取り付け説明書、サービスマニュアル、簡易説明書、またはWhite Rodgers 50A55-843のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、White Rodgers 50A55-843の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

White Rodgers 50A55-843デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWhite Rodgers 50A55-843を使用するのを助ける技術的文書のことです。説明書は通常、全てのWhite Rodgers 50A55-843ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

White Rodgersの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. White Rodgers 50A55-843の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWhite Rodgers 50A55-843の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。White Rodgers 50A55-843に関してこのドキュメントで見つけることができる全てのヒントの目次
3. White Rodgers 50A55-843デバイスの基本機能を使うにあたってのヒント。 White Rodgers 50A55-843のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。White Rodgers 50A55-843に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWhite Rodgers 50A55-843のメーカー/サービスへの連絡先に関する情報。

White Rodgers 50A55-843についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWhite Rodgers 50A55-843の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWhite Rodgers 50A55-843で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)