  • Black Box SW591C - page 1

    Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com CUSTOMER SUPPORT INFORMATION JUL Y 199 ...

  • Black Box SW591C - page 2

    FEDERAL COMMUNICA TIONS COMMISSION AND INDUSTR Y CANADA RADIO FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and f ...

  • Black Box SW591C - page 3

    Chapter Page 1 Specifications .............................................................................................................4 2 Introduction ...............................................................................................................5 3 Installation .................................................................. ...

  • Black Box SW591C - page 4

    Interface — RS-232 asynchronous (each port individually selectable for DTE or DCE) Connectors — Switch: (5) DB25S female; Switch with Expansion Board: (9) DB25S female Pins Suppor ted — 1-8, 20, 22 Speed — 110 to 19,200 bps (selectable by port) Memor y — 8K buffer Enclosure — Steel Operating T emperature — 32°F to 113°F (0° to 45° ...

  • Black Box SW591C - page 5

    The Code Operated Switch II (COS II) makes code-operated switching possible for diverse combinations of serial devices. As it switches, the COS II also reconciles differences in word size, speed, flow control, and parity for up to four devices. An Expansion Board, available separately , doubles the maximum number of devices, to eight. Configuration ...

  • Black Box SW591C - page 6

    3.1. Introduction In addition to this manual, your Switch package should contain one standard switch unit and a wallmounted power supply . After you’ve unpacked the Switch, take a few minutes to look through this manual. Y ou will need a screwdriver large enough to remove the case screws, and a small screwdriver or other edged tool for setting DI ...

  • Black Box SW591C - page 7

    The board layout for the Four -Port Expansion Board is shown on this page (Fig. 2). If you have ordered one, check your Board to make sure it matches. NOTE: Every time you change the DIP switch settings, you must press the reset button located on the front panel of the switch, or unplug the power supply. The COS-II will not process any data during ...

  • Black Box SW591C - page 8

    In addition, there are some system characteristics that are set with the eighth DIP switch of the individual port switch banks. Sections 3.6 and 3.7 explain these functions in depth. 3.4 Bank Assignments The individual port switch banks are assigned as follows: Bank Label Port SWA Master Device Port SWB 0 SWC 1 SWD 2 SWE 3 The Four -Port Expansion ...

  • Black Box SW591C - page 9

    Automatic Timeout The COS II times the inter vals between the reception of each character and the next. Y ou may instruct it to return to an unlinked state after inter vals of 2.5, 5, or 10 minutes, or you may disable this automatic timeout feature. SWF 5 and SWF 6 control this feature. control lead (DTR or CTS) will be dropped to prevent data loss ...

  • Black Box SW591C - page 10

    3.6.2 S ETTING THE A RMING C HARACTER WITH SWG Switch Bank SWG supplies a portion of the control-code sequence, the sequence that activates the Switch. The arming character , the ASCII code that alerts the COS-II to an upcoming switch action, is set with SWG. The settings are given in the chart below . For a more detailed explanation of control cod ...

  • Black Box SW591C - page 11

    ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 ’ 27 39 ON ON ON OFF OFF ON OFF OFF ( 28 40 OFF OFF OFF ON OFF ON OFF OFF ) 29 41 ON OFF OFF ON OFF ON OFF OFF * 2A 42 OFF ON OFF ON OFF ON OFF OFF + 2B 43 ON ON OFF ON OFF ON OFF OFF , 2C 44 OFF OFF ON ON OFF ON OFF OFF - 2D 45 ON OFF ON ON OFF ON OFF OFF . 2E 46 OF ...

  • Black Box SW591C - page 12

    CODE OPERA TED SWITCH II 12 ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 S 53 83 ON ON OFF OFF ON OFF ON OFF T 54 84 OFF OFF ON OFF ON OFF ON OFF U 55 85 ON OFF ON OFF ON OFF ON OFF V 56 86 OFF ON ON OFF ON OFF ON OFF W 57 87 ON ON ON OFF ON OFF ON OFF X 58 88 OFF OFF OFF ON ON OFF ON OFF Y 59 89 ON OFF OFF ON ON ...

  • Black Box SW591C - page 13

    ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 80 128 OFF OFF OFF OFF OFF OFF OFF ON 81 129 ON OFF OFF OFF OFF OFF OFF ON 82 130 OFF ON OFF OFF OFF OFF OFF ON 83 131 ON ON OFF OFF OFF OFF OFF ON 84 132 OFF OFF ON OFF OFF OFF OFF ON 85 133 ON OFF ON OFF OFF OFF OFF ON 86 134 OFF ON ON OFF OFF OFF OFF ON 87 135 ON ON ...

  • Black Box SW591C - page 14

    ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 AE 174 OFF ON ON ON OFF ON OFF ON AF 175 ON ON ON ON OFF ON OFF ON B0 176 OFF OFF OFF OFF ON ON OFF ON B1 177 ON OFF OFF OFF ON ON OFF ON B2 178 OFF ON OFF OFF ON ON OFF ON B3 179 ON ON OFF OFF ON ON OFF ON B4 180 OFF OFF ON OFF ON ON OFF ON B5 181 ON OFF ON OFF ON ON ...

  • Black Box SW591C - page 15

    ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 DF 223 ON ON ON ON ON OFF ON ON E0 224 OFF OFF OFF OFF OFF ON ON ON E1 225 ON OFF OFF OFF OFF ON ON ON E2 226 OFF ON OFF OFF OFF ON ON ON E3 227 ON ON OFF OFF OFF ON ON ON E4 228 OFF OFF ON OFF OFF ON ON ON E5 229 ON OFF ON OFF OFF ON ON ON E6 230 OFF ON ON OFF OFF ON ...

  • Black Box SW591C - page 16

    T o Set SWB 8 Pass breaks ON Ignore breaks OFF Lead Pass-Through This function allows the COS II either to pass hardware-handshake leads to connected devices, or to block them. If they are blocked, the leads will still be used to regulate the 8K internal buffer of the Switch. The following table shows the behavior of the COS II for different combin ...

  • Black Box SW591C - page 17

    3.9. Connecting and Powering Up the COS-II Once you have configured the internal switches and jumpers, you can connect your devices and the wallmounted power jack to the COS-II. Before you begin, you might wish to check the settings of all the DIP switches again, to make sure you have set them correctly . T o prepare the COS-II: 1. Make sure that S ...

  • Black Box SW591C - page 18

    4.1. Introduction The primary action of the Switch consists of detecting and responding to control-code sequences. As it switches to a particular port, the COS-II establishes a link between the master and the slave device. After the COS-II has switched, it can lock the link out, that is, it can ignore all requests by other ports until the link is b ...

  • Black Box SW591C - page 19

    4.6. Indicators The front panel of the Switch contains 10 LEDs. The Power LED, at the extreme right, will glow steadily when power is on. The Lockout LED, a green LED at the extreme left, will light when the unit is in lockout. Each of the eight port LEDs, numbered 0 through 7, will respond to the action of the COS II. When the master port is switc ...

  • Black Box SW591C - page 20

    CODE OPERA TED SWITCH II After you have hit a key , the screen will change to: Serial Por t T est The Serial Port T est is a loopback test that checks whether data is being correctly transmitted and received on any port. The test also checks, using DTR/CTS/RI or R TS/DCD, whether the box can loop back control leads correctly . T o use this test, yo ...

  • Black Box SW591C - page 21

    Individual Port Switch Bank Settings Switch Position Setting Option 1 2 3 4 5 6 7 Speed 110 bps ON ON ON 300 bps OFF ON ON 600 bps ON OFF ON 1200 bps OFF OFF ON 2400 bps ON ON OFF 4800 bps OFF ON OFF 9600 bps ON OFF OFF 19200 bps OFF OFF OFF Parity none OFF OFF even OFF ON odd ON OFF Word Size 7 bits per word OFF 8 bits per word ON Flow Control Har ...

  • Black Box SW591C - page 22

    System Switch Options A vailable through Position 8 Switch Option SWA 8 SWB 8 SWC 8 SWD 8 SWE 8 Self-test ON Normal operation OFF Pass breaks ON Ignore breaks OFF Lead pass-through ON Normal operation OFF Graphics Mode Pause In Master Data ON ON Slave Data OFF ON Master or slave data ON OFF Text Mode OFF OFF 22 CODE OPERA TED SWITCH II ...

  • Black Box SW591C - page 23

    1000 P ark Drive • Lawrence, P A 15055-1018 • 724-746-5500 • F ax 724-746-0746 ©Copyright 1999. Black Box Corporation. All rights reserved. ...

メーカー Black Box カテゴリー Network Card

Black Box SW591Cのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SW591Cの取扱説明書
- Black Boxの製品カード
- パンフレット
- またはBlack Box SW591Cの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Black Box SW591Cの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Black Box SW591Cの取り付け説明書、サービスマニュアル、簡易説明書、またはBlack Box SW591Cのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Black Box SW591Cの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Black Box SW591Cデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBlack Box SW591Cを使用するのを助ける技術的文書のことです。説明書は通常、全てのBlack Box SW591Cユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Black Boxの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Black Box SW591Cの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBlack Box SW591Cの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Black Box SW591Cに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Black Box SW591Cデバイスの基本機能を使うにあたってのヒント。 Black Box SW591Cのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Black Box SW591Cに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBlack Box SW591Cのメーカー/サービスへの連絡先に関する情報。

Black Box SW591Cについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBlack Box SW591Cの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBlack Box SW591Cで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)